title: "A. O. Smith Code 110 / 120 (Tankless): Meaning, Causes & Fix"
url: https://gcsradheat.com/error-codes/a-o-smith/ao-smith-tk-110/
description: "Showing A. O. Smith Code 110 / 120 (Tankless) means Ignition or flame loss fault on A. O. Smith ATI/ProLine tankless on A. O. Smith / Takagi Condensing."
---

OEM diagnostic fault code · A. O. Smith

# A. O. Smith Water Heater Code 110 / 120 (Tankless): Meaning & Diagnostic Steps

Showing A. O. Smith Code 110 / 120 (Tankless) means Ignition or flame loss fault on A. O. Smith ATI/ProLine tankless on A. O. Smith / Takagi Condensing Tankless. Recommended service scope (Licensed Gas Plumber Required) focuses on Undersized 1/2 in. gas supply failing 199K BTU/h load; Blocked exhaust or condensate trap.

- **Fault / Blink Code**: Code 110 / 120 (Tankless)

- **Control Platform**: A. O. Smith / Takagi Condensing Tankless

- **Severity Class**: Ignition / Gas Lockout

- **DIY vs. Pro Scope**: Licensed Gas Plumber Required

**Gas & Electrical Safety Protocol** If you detect a rotten-egg gas odor or observe scorched wiring, shut off the manual gas valve/breaker immediately, ventilate or evacuate, and call 911. Do not open sealed gas combustion chambers without proper licensing.

Hand turning red quarter-turn brass main water shutoff valve on three-quarter-inch copper line

## What Causes A. O. Smith Code 110 / 120 (Tankless)?

A. O. Smith Code 110 / 120 (Tankless) triggers on A. O. Smith / Takagi Condensing Tankless controls when ignition or flame loss fault on a. o. smith ati/proline tankless. Review the primary root causes and field diagnostic checks below before ordering replacement gas or ignition parts.

- Undersized 1/2 in. gas supply failing 199K BTU/h load
- Blocked exhaust or condensate trap

## How Do You Troubleshoot A. O. Smith Code 110 / 120 (Tankless) Step by Step?

Follow these 2 ordered OEM verification steps with power and gas safety checks first; escalate sealed-chamber manifold pressure measurements to a licensed gas plumber.

Sequential diagnostic steps for A. O. Smith Code 110 / 120 (Tankless)

| Step | Diagnostic Action |
|---|---|
| 01 | Check gas supply pressure under full fire |
| 02 | Verify condensate drain and flame rod cleanliness |

## What Control and Gas Pressure Thresholds Govern This Fault?

Compare measured gas manifold pressure, tankless 199,000 BTU/h startup flow, thermopile output, and T&P relief safety limits against OEM and IFGC Table 402.4 tolerances below.

Verified gas control, thermal cutoff, and OEM service baselines for A. O. Smith / Takagi Condensing Tankless

| Parameter | Verified Value | Reference Standard |
|---|---|---|
| Full-Fire Condensing Input Load | 199,000 BTU/h / 199 CFH | IFGC Table 402.4(2) |
| NG / LP Manifold Inlet Span | 3.5–10.5 in. w.c. (NG) / 8.0–13.0 in. w.c. (LP) | OEM Tankless Spec |
| Recommended DHW Setpoint | 120 °F | U.S. DOE / CPSC Anti-Scald |
| Min Flow Activation Rate | 0.4–0.5 GPM | OEM Flow Turbine Spec |
| Preventive Descale Flush Cycle | Every 12 months (>7.0 GPG hard water) | OEM Heat Exchanger Warranty |

## Which Related Water Heater Blink and Error Codes Should You Compare?

Cross-check 6 other residential tank and condensing tankless fault codes if multiple indicators blink or repeat after reset.

Other residential gas and tankless diagnostic fault codes

| Brand & Code | Meaning | Severity |
|---|---|---|
| [A. O. Smith 4 Flashes (Honeywell / White-Rodgers)](https://gcsradheat.com/error-codes/a-o-smith/ao-smith-4-flashes/) | Thermostat / ECO over-temperature limit fault | Over-Temperature Lockout |
| [A. O. Smith 1 Flash (Every 3s)](https://gcsradheat.com/error-codes/a-o-smith/ao-smith-1-flash/) | Normal operation — pilot lit and system ready | Normal Status Blink |
| [A. O. Smith 2 Flashes](https://gcsradheat.com/error-codes/a-o-smith/ao-smith-2-flashes/) | Thermopile voltage low (<325 mV) | Pilot Signal Weak |
| [A. O. Smith 5 Flashes](https://gcsradheat.com/error-codes/a-o-smith/ao-smith-5-flashes/) | Water temperature thermistor probe fault | Sensor Lockout |
| [A. O. Smith 6 Flashes](https://gcsradheat.com/error-codes/a-o-smith/ao-smith-6-flashes/) | Flame failure / pilot extinguished during heating | Ignition Dropout |
| [A. O. Smith 7 Flashes](https://gcsradheat.com/error-codes/a-o-smith/ao-smith-7-flashes/) | Flammable Vapor Sensor (FVS) / Thermal Cutout open | Safety Lockout |

## What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What causes A. O. Smith water heater code Code 110 / 120 (Tankless)?

Ignition or flame loss fault on A. O. Smith ATI/ProLine tankless. Common root causes on A. O. Smith / Takagi Condensing Tankless include Undersized 1/2 in. gas supply failing 199K BTU/h load; Blocked exhaust or condensate trap.

### How do technicians troubleshoot A. O. Smith Code 110 / 120 (Tankless)?

Verification steps: Check gas supply pressure under full fire Verify condensate drain and flame rod cleanliness Always follow 911 evacuation protocols before cycling gas or electrical controls.

### Can a homeowner reset A. O. Smith Code 110 / 120 (Tankless) safely?

Scope: Licensed Gas Plumber Required. First verify gas odor absence and follow ordered visual checks before cycling power; escalate persistent lockouts to a licensed gas plumber.

### What gas pressure or temperature thresholds affect A. O. Smith Code 110 / 120 (Tankless)?

Standard A. O. Smith / Takagi Condensing Tankless checks verify Full-Fire Condensing Input Load (199,000 BTU/h / 199 CFH) and NG / LP Manifold Inlet Span (3.5–10.5 in. w.c. (NG) / 8.0–13.0 in. w.c. (LP)).

### Where do the engineering metrics for A. O. Smith Code 110 / 120 (Tankless) originate?

Data provenance for A. O. Smith Code 110 / 120 (Tankless) links straight to verified agency releases and OEM installation bulletins. Control family: A. O. Smith / Takagi Condensing Tankless. Severity: Ignition / Gas Lockout.

### When should homeowners stop and call 911 or a pro on A. O. Smith Code 110 / 120 (Tankless)?

Online tables clarify baseline engineering limits, not site-specific hazards like live gas odors or corroded service mains. Do not open sealed gas burner compartments or bypass ECO high-limit switches without proper licensing.

### Which federal regulatory baselines intersect with A. O. Smith Code 110 / 120 (Tankless)?

Check local Authority Having Jurisdiction amendments to IPC/UPC codes alongside federal EPA drinking water and 10 CFR 430 efficiency mandates.

### Which incentives remain open in 2026 for plumbing equipment?

Verify active state DOE HEAR allocations (up to $1,750 for heat pump water heaters) and local utility rebates following the Dec 31, 2025 25C expiration.

## Which Related Error Codes and Tools Should You Check?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Decode Your Water Heater Serial Age & CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Verify Gas Line Sizing With Pipe Sizer Tool→](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/)
- [Emergency Shutoff Triage For Gas Leaks & Tank Faults→](https://gcsradheat.com/emergency/)
- [Noritz Code 11: Ignition failure (no flame detected)→](https://gcsradheat.com/error-codes/noritz/noritz-11/)
- [Noritz Code 12: Flame loss during operation→](https://gcsradheat.com/error-codes/noritz/noritz-12/)

## Sources

1. [A. O. Smith Residential Water Heater Serial Number & Diagnostics Documentation](https://www.hotwater.com/resources/warranty-lookup.html) — A. O. Smith Corporation, OEM Technical Bulletins (retrieved 2026-11-23)
2. [NFPA 54 / ANSI Z223.1 National Fuel Gas Code (Gas Pipe Sizing Ch. 6)](https://www.nfpa.org/codes-and-standards/nfpa-54-standard-development/54) — National Fire Protection Association, 2024 Edition (retrieved 2026-11-23)

Check warranty first

Many gas control valves and heat exchangers carry 6–12 year OEM parts warranties. Confirm unit manufacture date before ordering parts.
[Check Serial Warranty](https://gcsradheat.com/tools/serial-number-lookup/) [A. O. Smith Brand Overview](https://gcsradheat.com/brands/a-o-smith/)