---
title: "Chicago Faucet WWG50-E35-317XKAB WWG50 (Bathroom Faucets)"
url: https://gcsradheat.com/fixtures/bathroom-sink-faucet/chicago-faucet/wwg50/
description: "Across 3 finish and trim variants merged cleanly under this model platform, the Chicago Faucet WWG50 (WWG50-E35-317XKAB) WaterSense bathroom faucets."
---

WaterSense datasheet · Chicago Faucet (WWG50-E35-317XKAB)

# Chicago Faucet WWG50 WaterSense Bathroom Faucet Specs (WWG50-E35-317XKAB)

Across 3 finish and trim variants merged cleanly under this model platform, the Chicago Faucet WWG50 (WWG50-E35-317XKAB) WaterSense bathroom faucets architecture maintains a certified 1.5 GPM rating. Expect 31.8% lower flow than EPAct benchmarks (~4,088 gal/yr in a 4-person household), where it passes federal WaterSense, though exceeds California Title 20 (1.2 GPM).

- **Certified Rating** : 1.5 GPM

- **EPAct Flow Savings** : 31.8%

- **Finish SKUs Merged** : 3

- **CA Title 20 Fit** : Federal Only

- **Rep. SKU** : WWG50-E35-317XKAB

Engineering summary for WWG50-E35-317XKAB

Stepping down from federal 2.2 GPM hardware to 1.5 GPM on Chicago Faucet WWG50 delivers 31.8% lower usage per cycle—translating to 2,044 gal/yr saved for couples and 4,088 gal/yr for four-person households.

Because 55% of bathroom faucets draw relies on heated water, a 4-person home using electric water heating at $0.18/kWh saves an estimated $53/yr in electricity on top of $59/yr in municipal water and sewer charges.

## Where Does Chicago Faucet WWG50 Sit Against Category Baselines?

Audited against official EPA WaterSense product registries, Chicago Faucet WWG50 engineering specifications below cover rated output, variant scope, and strict state compliance.

Verified EPA WaterSense & federal flow-rate benchmarks for Chicago Faucet WWG50

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Chicago Faucet WWG50 | 1,944 cat. peers | Primary SKU: WWG50-E35-317XKAB |
| Rated Hydraulic Efficiency | 1.5 GPM | 2.2 GPM EPAct | 31.8% reduction vs federal ceiling |
| State Title 20 Status | Exceeds Strict State Cap | <= 1.2 GPM | Installable outside 1.28/1.8/1.2 cap states |
| Consolidated Trim Count | 3 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Faucet | ASME A112.19.2 | Standard trapway |

## Why Does Upgrading to 1.5 GPM Lower Monthly Costs?

Model estimated gallon and dollar reductions across 2-person and 4-person homes using Chicago Faucet WWG50 compared with legacy federal baseline plumbing hardware.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 2,044 gal/yr | $30/yr | $27/yr | **$57/yr** |
| 4-Person Family (US Avg Rate) | 4,088 gal/yr | $59/yr | $53/yr | **$112/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 4,088 gal/yr | $88/yr | $85/yr | **$173/yr** |
| 10-Year Cumulative Savings (4-Person) | 40,880 gal | $590 | $530 | **$1,120** |

## Which Trim & Rough-In SKUs Belong to WWG50?

Confirm exact SKU ordering codes and representative finish trims sharing Chicago Faucet WWG50's EPA-certified internal valve body or trapway geometry below.

Finish & trim SKUs sharing the WWG50 certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| WWG50-E35-317XKAB | Chicago Faucet WWG50 (Representative SKU) | 1.5 GPM | EPA WaterSense |
| WWG50-E35ABCP | Chicago Faucet WWG50 (Alternate Trim / Rough-In) | 1.5 GPM | EPA WaterSense |
| WWG50-E35XKABCP | Chicago Faucet WWG50 (Alternate Trim / Rough-In) | 1.5 GPM | EPA WaterSense |

## Which Other Brands Match Chicago Faucet WWG50's Flow Class?

Four peer bathroom faucets series from our deduplicated EPA WaterSense catalog appear below for quick side-by-side flow and savings verification.

Comparable WaterSense fixture series in WaterSense Bathroom Sink Faucets

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Chicago Faucet WWG420](https://gcsradheat.com/fixtures/bathroom-sink-faucet/chicago-faucet/wwg420/) | WWG420-ABCP | 1.5 GPM | 54.5% | 8 |
| [Chicago Faucet WWG445](https://gcsradheat.com/fixtures/bathroom-sink-faucet/chicago-faucet/wwg445/) | WWG445-DJ13E35ABCP | 1.5 GPM | 31.8% | 5 |
| [Chicago Faucet WWG540](https://gcsradheat.com/fixtures/bathroom-sink-faucet/chicago-faucet/wwg540/) | WWG540-LDE35ABCP | 1.5 GPM | 31.8% | 3 |
| [Chicago Faucet WWG786](https://gcsradheat.com/fixtures/bathroom-sink-faucet/chicago-faucet/wwg786/) | WWG786-E35ABCP | 1.5 GPM | 54.5% | 8 |

## When Should Homeowners Double-Check Fitment Before Installing Chicago Faucet WWG50?

Low-flow fixtures save money across 3 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 31.8% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Common Questions About Chicago Faucet WWG50

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Chicago Faucet WWG50 (WWG50-E35-317XKAB) meet California Title 20 and federal WaterSense flow rules?

Partially—Chicago Faucet WWG50 carries EPA WaterSense certification at 1.5 GPM, which passes federal rules though states capping flow at 1.2 GPM require a lower-flow trim.

### What is the difference between trim variants listed under Chicago Faucet WWG50?

All 3 consolidated SKUs share identical WaterSense hydraulic specs (1.5 GPM) and differ mainly by exterior finish, handle style, or packaging.

## Check Local Water Hardness & Plumbing Tools

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Chicago Faucet WWG420→](https://gcsradheat.com/fixtures/bathroom-sink-faucet/chicago-faucet/wwg420/)
- [Compare Chicago Faucet WWG445→](https://gcsradheat.com/fixtures/bathroom-sink-faucet/chicago-faucet/wwg445/)
- [Browse All WaterSense Bathroom Faucets→](https://gcsradheat.com/fixtures/bathroom-sink-faucet/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Pre-Order Check

### Chicago Faucet WWG50-E35-317XKAB Summary

Meets federal EPA WaterSense at 1.5 GPM.
[All WaterSense Bathroom Sink Faucets](https://gcsradheat.com/fixtures/bathroom-sink-faucet/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)
