title: "American Standard 624B.013.xxx 624B (Flushing Urinals)"
url: https://gcsradheat.com/fixtures/flushing-urinal/american-standard/624b/
description: "Consolidating 2 finish and trim variants merged cleanly under this model platform, American Standard's 624B (624B.013.xxx) delivers a verified 0.5 GPF flow."
---

WaterSense verified · American Standard 624B.013.xxx

# American Standard 624B WaterSense Flushing Urinal Specs (624B.013.xxx)

Consolidating 2 finish and trim variants merged cleanly under this model platform, American Standard's 624B (624B.013.xxx) delivers a verified 0.5 GPF flow rating in the flushing urinals category. That yields a 50.0% reduction below federal EPAct baselines (~1,096–2,192 gal saved yearly) and passes federal WaterSense, though exceeds California Title 20 (0.125 GPF).

- **Certified Rating** : 0.5 GPF

- **EPAct Flow Savings** : 50.0%

- **Finish SKUs Merged** : 2

- **CA Title 20 Fit** : Federal Only

- **Rep. SKU** : 624B.013.xxx

Efficiency breakdown — American Standard 624B

Stepping down from federal 1.0 GPF hardware to 0.5 GPF on American Standard 624B delivers 50.0% lower usage per cycle—translating to 1,096 gal/yr saved for couples and 2,192 gal/yr for four-person households.

Valve hydraulic geometry (Pressurized) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 2 consolidated trim SKUs.

## Which Hydraulic Specs Define American Standard 624B (624B.013.xxx)?

Inspect certified flow rating, federal baseline gap, strict California Title 20 status, and consolidation counts across the American Standard 624B product series below.

Verified EPA WaterSense & federal flow-rate benchmarks for American Standard 624B

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | American Standard 624B | 154 cat. peers | Primary SKU: 624B.013.xxx |
| Rated Hydraulic Efficiency | 0.5 GPF | 1.0 GPF EPAct | 50.0% reduction vs federal ceiling |
| State Title 20 Status | Exceeds Strict State Cap | <= 0.125 GPF | Installable outside 1.28/1.8/1.2 cap states |
| Consolidated Trim Count | 2 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Valve | ASME A112.19.2 | Pressurized |

## How Rapidly Does 624B Cut Household Water Bills?

Lower gallon usage reduces both municipal meter bills and water heating fuel loads—compare multi-year household cost scenarios for 624B.013.xxx below.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,096 gal/yr | $16/yr | $0/yr | **$16/yr** |
| 4-Person Family (US Avg Rate) | 2,192 gal/yr | $32/yr | $0/yr | **$32/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 2,192 gal/yr | $48/yr | $0/yr | **$48/yr** |
| 10-Year Cumulative Savings (4-Person) | 21,920 gal | $320 | $0 | **$320** |

## How Many Finish Variants Map to American Standard 624B?

Instead of repeating thin duplicate pages for identical internal valves, 2 verified American Standard hardware configurations roll up cleanly into this single benchmark.

Finish & trim SKUs sharing the 624B certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| 624B.013.xxx | American Standard 624B (Representative SKU) | 0.5 GPF | EPA WaterSense |
| 624B.051.xxx | American Standard 624B (Alternate Trim / Rough-In) | 0.5 GPF | EPA WaterSense |

## Which Peer WaterSense Series Offer Similar Output?

Four competing WaterSense flushing urinals alternatives sit alongside American Standard 624B in the sortable comparison matrix below for side-by-side homeowner vetting.

Comparable WaterSense fixture series in WaterSense Flushing Urinals

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Zurn Industries Small Pint](https://gcsradheat.com/fixtures/flushing-urinal/zurn-industries/small-pint/) | Z5738-U | 0.125 GPF | 87.5% | 4 |
| [American Standard 6245](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/6245/) | 6245.013.xxx | 0.125 GPF | 87.5% | 2 |
| [American Standard Decorum](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/decorum/) | 6042.453.020 | 0.125 GPF | 87.5% | 4 |
| [American Standard FloWise](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/flowise/) | 6045.013-xxx | 0.5 GPF | 87.5% | 3 |

## When Should Homeowners Double-Check Fitment Before Installing American Standard 624B?

Low-flow fixtures save money across 2 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 50.0% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Key Homeowner Answers for American Standard 624B.013.xxx

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does American Standard 624B (624B.013.xxx) meet California Title 20 and federal WaterSense flow rules?

Partially—American Standard 624B carries EPA WaterSense certification at 0.5 GPF, which passes federal rules though states capping flow at 0.125 GPF require a lower-flow trim.

### What is the difference between trim variants listed under American Standard 624B?

All 2 consolidated SKUs share identical WaterSense hydraulic specs (0.5 GPF) and differ mainly by exterior finish, handle style, or packaging.

## Cartridge, Hardness & Softener Guides

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Zurn Industries Small Pint→](https://gcsradheat.com/fixtures/flushing-urinal/zurn-industries/small-pint/)
- [Compare American Standard 6245→](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/6245/)
- [Browse All WaterSense Flushing Urinals→](https://gcsradheat.com/fixtures/flushing-urinal/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Spec Snapshot · American Standard

### 0.5 GPF Output

Cuts tap demand by 50.0% over baseline units across 2 finish options.
[All WaterSense Flushing Urinals](https://gcsradheat.com/fixtures/flushing-urinal/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)