title: "American Standard 6045SM.013 Side Mount (Flushing Urinals)"
url: https://gcsradheat.com/fixtures/flushing-urinal/american-standard/side-mount/
description: "American Standard Side Mount (rep. SKU 6045SM.013) is an EPA WaterSense flushing urinals series certified at 0.125 GPF, grouping 2 finish and trim variants."
---

EPA WaterSense flushing urinals · American Standard (6045SM.013)

# American Standard Side Mount WaterSense Flushing Urinal Specs (6045SM.013)

American Standard Side Mount (rep. SKU 6045SM.013) is an EPA WaterSense flushing urinals series certified at 0.125 GPF, grouping 2 finish and trim variants merged cleanly under this model platform. Compared to the federal 1.0 GPF limit, it trims water demand by 87.5% (~3,832 gal/yr in a 4-person home) and meets strict California Title 20 / CO / WA limits.

- **Certified Rating** : 0.125 GPF

- **EPAct Flow Savings** : 87.5%

- **Finish SKUs Merged** : 2

- **CA Title 20 Fit** : Compliant

- **Rep. SKU** : 6045SM.013

Flow savings & state code fit for American Standard Side Mount

Stepping down from federal 1.0 GPF hardware to 0.125 GPF on American Standard Side Mount delivers 87.5% lower usage per cycle—translating to 1,916 gal/yr saved for couples and 3,832 gal/yr for four-person households.

Valve hydraulic geometry (Pressurized) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 2 consolidated trim SKUs.

## How Does American Standard Side Mount Compare to Federal 1.0 GPF Caps?

Core hydraulic measurements, strict state compliance status, and consolidated trim counts for the American Standard Side Mount platform (6045SM.013) are audited below.

Verified EPA WaterSense & federal flow-rate benchmarks for American Standard Side Mount

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | American Standard Side Mount | 154 cat. peers | Primary SKU: 6045SM.013 |
| Rated Hydraulic Efficiency | 0.125 GPF | 1.0 GPF EPAct | 87.5% reduction vs federal ceiling |
| State Title 20 Status | Compliant | <= 0.125 GPF | Eligible in CA, CO, WA, NY & VT |
| Consolidated Trim Count | 2 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Valve | ASME A112.19.2 | Pressurized |

## How Much Water and Money Does Side Mount Save Annually?

Projected tap volume, sewer tariff, and hot water heating reductions below benchmark American Standard Side Mount against older EPAct baseline fixtures.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,916 gal/yr | $28/yr | $0/yr | **$28/yr** |
| 4-Person Family (US Avg Rate) | 3,832 gal/yr | $56/yr | $0/yr | **$56/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 3,832 gal/yr | $84/yr | $0/yr | **$84/yr** |
| 10-Year Cumulative Savings (4-Person) | 38,320 gal | $560 | $0 | **$560** |

## Which Trim SKUs Share the American Standard Side Mount Hydraulic Design?

We merged 2 finish or rough-in SKUs under this single American Standard engineering platform; up to 10 verified SKU codes are listed below.

Finish & trim SKUs sharing the Side Mount certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| 6045SM.013 | American Standard Side Mount (Representative SKU) | 0.125 GPF | EPA WaterSense |
| 6045SM.051 | American Standard Side Mount (Alternate Trim / Rough-In) | 0.125 GPF | EPA WaterSense |

## Which Flushing Urinals Series Compare Closest to American Standard Side Mount?

Compare four nearby WaterSense flushing urinals series alongside rated flow, EPAct savings percentage, and trim counts.

Comparable WaterSense fixture series in WaterSense Flushing Urinals

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [American Standard Pintbrook](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/pintbrook/) | 6002.001 | 0.125 GPF | 87.5% | 10 |
| [American Standard Selectronic](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/selectronic/) | 6061.013-xxx | 0.5 GPF | 87.5% | 44 |
| [American Standard Ultima](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/ultima/) | 6145.013 | 0.125 GPF | 87.5% | 4 |
| [American Standard Washbrook](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/washbrook/) | 6590001USMCA.XXX | 0.125 GPF | 87.5% | 3 |

## When Should Homeowners Double-Check Fitment Before Installing American Standard Side Mount?

Low-flow fixtures save money across 2 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 87.5% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Installation & Code Questions for American Standard Side Mount

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does American Standard Side Mount (6045SM.013) meet California Title 20 and federal WaterSense flow rules?

Yes—American Standard Side Mount carries EPA WaterSense certification at 0.125 GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

### What is the difference between trim variants listed under American Standard Side Mount?

All 2 consolidated SKUs share identical WaterSense hydraulic specs (0.125 GPF) and differ mainly by exterior finish, handle style, or packaging.

## Related Fixture & Plumbing Guides for American Standard

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American Standard Pintbrook→](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/pintbrook/)
- [Compare American Standard Selectronic→](https://gcsradheat.com/fixtures/flushing-urinal/american-standard/selectronic/)
- [Browse All WaterSense Flushing Urinals→](https://gcsradheat.com/fixtures/flushing-urinal/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installer note · 6045SM.013

### American Standard Side Mount Fit Check

Confirm drain line slope, pressure balancing or supply stop sizes before installing a 0.125 GPF flushing urinal.
[All WaterSense Flushing Urinals](https://gcsradheat.com/fixtures/flushing-urinal/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)