title: "Kohler K-20713-ET-** Tend (Flushing Urinals)"
url: https://gcsradheat.com/fixtures/flushing-urinal/kohler/tend/
description: "Engineered as a WaterSense-listed flushing urinals series, Kohler Tend (starting at K-20713-ET-**) operates at 0.125 GPF across 10 finish and trim variants."
---

Canonical series spec · Kohler K-20713-ET-**

# Kohler Tend WaterSense Flushing Urinal Specs (K-20713-ET-**)

Engineered as a WaterSense-listed flushing urinals series, Kohler Tend (starting at K-20713-ET-**) operates at 0.125 GPF across 10 finish and trim variants merged cleanly under this model platform. Replacing a standard 1.0 GPF unit saves 87.5% annually on tap volume; performance meets strict California Title 20 / CO / WA limits. Inspect full SKU variations, regional bill savings across 2-person and 4-person homes, and 154 peer flushing urinals series below.

- **Certified Rating** : 0.125 GPF

- **EPAct Flow Savings** : 87.5%

- **Finish SKUs Merged** : 10

- **CA Title 20 Fit** : Compliant

- **Rep. SKU** : K-20713-ET-**

Plumbing impact — Tend

Stepping down from federal 1.0 GPF hardware to 0.125 GPF on Kohler Tend delivers 87.5% lower usage per cycle—translating to 1,916 gal/yr saved for couples and 3,832 gal/yr for four-person households.

Fixture hydraulic geometry (standard valve) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 10 consolidated trim SKUs.

## Is Kohler Tend Compliant With 2026 State Flow Caps?

Check federal EPAct ceilings versus strict California Title 20, Colorado, Washington, and New York flow limits for Kohler Tend (K-20713-ET-**) in this specification audit.

Verified EPA WaterSense & federal flow-rate benchmarks for Kohler Tend

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Kohler Tend | 154 cat. peers | Primary SKU: K-20713-ET-** |
| Rated Hydraulic Efficiency | 0.125 GPF | 1.0 GPF EPAct | 87.5% reduction vs federal ceiling |
| State Title 20 Status | Compliant | <= 0.125 GPF | Eligible in CA, CO, WA, NY & VT |
| Consolidated Trim Count | 10 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Fixture | ASME A112.19.2 | Standard trapway |

## What Does Kohler Tend Save Over 10 Years?

Cumulative decade savings below quantify avoided tap gallons and combined utility bills when stepping down older fixtures to 0.125 GPF.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,916 gal/yr | $28/yr | $0/yr | **$28/yr** |
| 4-Person Family (US Avg Rate) | 3,832 gal/yr | $56/yr | $0/yr | **$56/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 3,832 gal/yr | $84/yr | $0/yr | **$84/yr** |
| 10-Year Cumulative Savings (4-Person) | 38,320 gal | $560 | $0 | **$560** |

## Which Representative SKUs Are Covered Under Tend?

Verify representative model numbers, finish codes, and certified flow ratings consolidated cleanly under the Kohler Tend EPA WaterSense product certificate below.

Finish & trim SKUs sharing the Tend certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| K-20713-ET-** | Kohler Tend (Representative SKU) | 0.125 GPF | EPA WaterSense |
| K-20713-ET125-** | Kohler Tend (Alternate Trim / Rough-In) | 0.125 GPF | EPA WaterSense |
| K-20713-ETS25-** | Kohler Tend (Alternate Trim / Rough-In) | 0.125 GPF | EPA WaterSense |
| K-28079-ER-** | Kohler Tend (Alternate Trim / Rough-In) | 0.125 GPF | EPA WaterSense |
| K-28079-ET-** | Kohler Tend (Alternate Trim / Rough-In) | 0.125 GPF | EPA WaterSense |

## What Comparable Flushing Urinals Models Should You Cross-Shop?

Evaluate four comparable WaterSense flushing urinals series ranked nearby in our catalog before finalizing valve compatibility or rough-in orders.

Comparable WaterSense fixture series in WaterSense Flushing Urinals

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Kohler Stanwell](https://gcsradheat.com/fixtures/flushing-urinal/kohler/stanwell/) | K-25048-ER-** | 0.5 GPF | 50.0% | 2 |
| [Kohler Steward Hybrid](https://gcsradheat.com/fixtures/flushing-urinal/kohler/steward-hybrid/) | K-5244-ER-** | 0.125 GPF | 87.5% | 2 |
| [Kohler Tend Touchless](https://gcsradheat.com/fixtures/flushing-urinal/kohler/tend-touchless/) | K-28082-1DC-** | 0.125 GPF | 87.5% | 2 |
| [Kohler Touchless](https://gcsradheat.com/fixtures/flushing-urinal/kohler/touchless/) | K-10949-YY | 0.125 GPF | 87.5% | 2 |

## When Should Homeowners Double-Check Fitment Before Installing Kohler Tend?

Low-flow fixtures save money across 10 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 87.5% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Homeowner & Contractor Questions: Tend

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Kohler Tend (K-20713-ET-**) meet California Title 20 and federal WaterSense flow rules?

Yes—Kohler Tend carries EPA WaterSense certification at 0.125 GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

### What is the difference between trim variants listed under Kohler Tend?

All 10 consolidated SKUs share identical WaterSense hydraulic specs (0.125 GPF) and differ mainly by exterior finish, handle style, or packaging.

## More Flushing Urinals & Plumbing Standards

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Kohler Stanwell→](https://gcsradheat.com/fixtures/flushing-urinal/kohler/stanwell/)
- [Compare Kohler Steward Hybrid→](https://gcsradheat.com/fixtures/flushing-urinal/kohler/steward-hybrid/)
- [Browse All WaterSense Flushing Urinals→](https://gcsradheat.com/fixtures/flushing-urinal/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Flushing Urinals Fit

### 10 Trim SKUs Consolidated

Confirm valve stem compatibility or porcelain rough-in clearances prior to ordering K-20713-ET-**.
[All WaterSense Flushing Urinals](https://gcsradheat.com/fixtures/flushing-urinal/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)