title: "Mansfield 410HE Cascade (Flushing Urinals)"
url: https://gcsradheat.com/fixtures/flushing-urinal/mansfield/cascade/
description: "Mansfield Cascade (rep. SKU 410HE) is an EPA WaterSense flushing urinals series certified at 0.5 GPF, grouping 2 finish and trim variants merged cleanly under."
---

EPA WaterSense flushing urinals · Mansfield (410HE)

# Mansfield Cascade WaterSense Flushing Urinal Specs (410HE)

Mansfield Cascade (rep. SKU 410HE) is an EPA WaterSense flushing urinals series certified at 0.5 GPF, grouping 2 finish and trim variants merged cleanly under this model platform. Compared to the federal 1.0 GPF limit, it trims water demand by 87.5% (~3,832 gal/yr in a 4-person home) and meets strict California Title 20 / CO / WA limits.

- **Certified Rating** : 0.5 GPF

- **EPAct Flow Savings** : 87.5%

- **Finish SKUs Merged** : 2

- **CA Title 20 Fit** : Compliant

- **Rep. SKU** : 410HE

Flow savings & state code fit for Mansfield Cascade

Stepping down from federal 1.0 GPF hardware to 0.5 GPF on Mansfield Cascade delivers 87.5% lower usage per cycle—translating to 1,916 gal/yr saved for couples and 3,832 gal/yr for four-person households.

Fixture hydraulic geometry (standard valve) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 2 consolidated trim SKUs.

## How Does Mansfield Cascade Compare to Federal 1.0 GPF Caps?

Core hydraulic measurements, strict state compliance status, and consolidated trim counts for the Mansfield Cascade platform (410HE) are audited below.

Verified EPA WaterSense & federal flow-rate benchmarks for Mansfield Cascade

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Mansfield Cascade | 154 cat. peers | Primary SKU: 410HE |
| Rated Hydraulic Efficiency | 0.5 GPF | 1.0 GPF EPAct | 87.5% reduction vs federal ceiling |
| State Title 20 Status | Compliant | <= 0.125 GPF | Eligible in CA, CO, WA, NY & VT |
| Consolidated Trim Count | 2 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Fixture | ASME A112.19.2 | Standard trapway |

## How Much Water and Money Does Cascade Save Annually?

Projected tap volume, sewer tariff, and hot water heating reductions below benchmark Mansfield Cascade against older EPAct baseline fixtures.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,916 gal/yr | $28/yr | $0/yr | **$28/yr** |
| 4-Person Family (US Avg Rate) | 3,832 gal/yr | $56/yr | $0/yr | **$56/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 3,832 gal/yr | $84/yr | $0/yr | **$84/yr** |
| 10-Year Cumulative Savings (4-Person) | 38,320 gal | $560 | $0 | **$560** |

## Which Trim SKUs Share the Mansfield Cascade Hydraulic Design?

We merged 2 finish or rough-in SKUs under this single Mansfield engineering platform; up to 10 verified SKU codes are listed below.

Finish & trim SKUs sharing the Cascade certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| 410HE | Mansfield Cascade (Representative SKU) | 0.5 GPF | EPA WaterSense |
| 410 UHE | Mansfield Cascade (Alternate Trim / Rough-In) | 0.5 GPF | EPA WaterSense |

## Which Flushing Urinals Series Compare Closest to Mansfield Cascade?

Compare four nearby WaterSense flushing urinals series alongside rated flow, EPAct savings percentage, and trim counts.

Comparable WaterSense fixture series in WaterSense Flushing Urinals

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Kohler Tend Touchless](https://gcsradheat.com/fixtures/flushing-urinal/kohler/tend-touchless/) | K-28082-1DC-** | 0.125 GPF | 87.5% | 2 |
| [Kohler Touchless](https://gcsradheat.com/fixtures/flushing-urinal/kohler/touchless/) | K-10949-YY | 0.125 GPF | 87.5% | 2 |
| [Sloan CX-8198](https://gcsradheat.com/fixtures/flushing-urinal/sloan/cx-8198/) | CX 8198-0.25*** | 0.25 GPF | 75.0% | 2 |
| [Sloan TruFlush](https://gcsradheat.com/fixtures/flushing-urinal/sloan/truflush/) | TRF-196-0.25*** | 0.25 GPF | 75.0% | 4 |

## When Should Homeowners Double-Check Fitment Before Installing Mansfield Cascade?

Low-flow fixtures save money across 2 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 87.5% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Installation & Code Questions for Mansfield Cascade

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Mansfield Cascade (410HE) meet California Title 20 and federal WaterSense flow rules?

Yes—Mansfield Cascade carries EPA WaterSense certification at 0.5 GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

### What is the difference between trim variants listed under Mansfield Cascade?

All 2 consolidated SKUs share identical WaterSense hydraulic specs (0.5 GPF) and differ mainly by exterior finish, handle style, or packaging.

## Related Fixture & Plumbing Guides for Mansfield

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Kohler Tend Touchless→](https://gcsradheat.com/fixtures/flushing-urinal/kohler/tend-touchless/)
- [Compare Kohler Touchless→](https://gcsradheat.com/fixtures/flushing-urinal/kohler/touchless/)
- [Browse All WaterSense Flushing Urinals→](https://gcsradheat.com/fixtures/flushing-urinal/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installer note · 410HE

### Mansfield Cascade Fit Check

Confirm drain line slope, pressure balancing or supply stop sizes before installing a 0.5 GPF flushing urinal.
[All WaterSense Flushing Urinals](https://gcsradheat.com/fixtures/flushing-urinal/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)