title: "Willoughby Industries UW-1317-HEU-BS Contoured High-Efficiency"
url: https://gcsradheat.com/fixtures/flushing-urinal/willoughby-industries/contoured-high-efficiency-urinals/
description: "Willoughby Industries Contoured High-Efficiency Urinals (rep. SKU UW-1317-HEU-BS) is an EPA WaterSense flushing urinals series certified at 0.5 GPF, grouping 4."
---

EPA WaterSense flushing urinals · Willoughby Industries (UW-1317-HEU-BS)

# Willoughby Industries Contoured High-Efficiency Urinals WaterSense Flushing Urinal Specs (UW-1317-HEU-BS)

Willoughby Industries Contoured High-Efficiency Urinals (rep. SKU UW-1317-HEU-BS) is an EPA WaterSense flushing urinals series certified at 0.5 GPF, grouping 4 finish and trim variants merged cleanly under this model platform. Compared to the federal 1.0 GPF limit, it trims water demand by 50.0% (~2,192 gal/yr in a 4-person home) and passes federal WaterSense, though exceeds California Title 20 (0.125 GPF).

- **Certified Rating** : 0.5 GPF

- **EPAct Flow Savings** : 50.0%

- **Finish SKUs Merged** : 4

- **CA Title 20 Fit** : Federal Only

- **Rep. SKU** : UW-1317-HEU-BS

Flow savings & state code fit for Willoughby Industries Contoured High-Efficiency Urinals

Stepping down from federal 1.0 GPF hardware to 0.5 GPF on Willoughby Industries Contoured High-Efficiency Urinals delivers 50.0% lower usage per cycle—translating to 1,096 gal/yr saved for couples and 2,192 gal/yr for four-person households.

Fixture hydraulic geometry (standard valve) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 4 consolidated trim SKUs.

## How Does Willoughby Industries Contoured High-Efficiency Urinals Compare to Federal 1.0 GPF Caps?

Core hydraulic measurements, strict state compliance status, and consolidated trim counts for the Willoughby Industries Contoured High-Efficiency Urinals platform (UW-1317-HEU-BS) are audited below.

Verified EPA WaterSense & federal flow-rate benchmarks for Willoughby Industries Contoured High-Efficiency Urinals

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Willoughby Industries Contoured High-Efficiency Urinals | 154 cat. peers | Primary SKU: UW-1317-HEU-BS |
| Rated Hydraulic Efficiency | 0.5 GPF | 1.0 GPF EPAct | 50.0% reduction vs federal ceiling |
| State Title 20 Status | Exceeds Strict State Cap | <= 0.125 GPF | Installable outside 1.28/1.8/1.2 cap states |
| Consolidated Trim Count | 4 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Fixture | ASME A112.19.2 | Standard trapway |

## How Much Water and Money Does Contoured High-Efficiency Urinals Save Annually?

Projected tap volume, sewer tariff, and hot water heating reductions below benchmark Willoughby Industries Contoured High-Efficiency Urinals against older EPAct baseline fixtures.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,096 gal/yr | $16/yr | $0/yr | **$16/yr** |
| 4-Person Family (US Avg Rate) | 2,192 gal/yr | $32/yr | $0/yr | **$32/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 2,192 gal/yr | $48/yr | $0/yr | **$48/yr** |
| 10-Year Cumulative Savings (4-Person) | 21,920 gal | $320 | $0 | **$320** |

## Which Trim SKUs Share the Willoughby Industries Contoured High-Efficiency Urinals Hydraulic Design?

We merged 4 finish or rough-in SKUs under this single Willoughby Industries engineering platform; up to 10 verified SKU codes are listed below.

Finish & trim SKUs sharing the Contoured High-Efficiency Urinals certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| UW-1317-HEU-BS | Willoughby Industries Contoured High-Efficiency Urinals (Representative SKU) | 0.5 GPF | EPA WaterSense |
| UW-1317-HEU-FA-BS | Willoughby Industries Contoured High-Efficiency Urinals (Alternate Trim / Rough-In) | 0.5 GPF | EPA WaterSense |
| UW-1317-HEU-FA-TS | Willoughby Industries Contoured High-Efficiency Urinals (Alternate Trim / Rough-In) | 0.5 GPF | EPA WaterSense |
| UW-1317-HEU-TS | Willoughby Industries Contoured High-Efficiency Urinals (Alternate Trim / Rough-In) | 0.5 GPF | EPA WaterSense |

## Which Flushing Urinals Series Compare Closest to Willoughby Industries Contoured High-Efficiency Urinals?

Compare four nearby WaterSense flushing urinals series alongside rated flow, EPAct savings percentage, and trim counts.

Comparable WaterSense fixture series in WaterSense Flushing Urinals

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Toto EcoPower](https://gcsradheat.com/fixtures/flushing-urinal/toto/ecopower/) | TEU1LA* | 0.125 GPF | 87.5% | 15 |
| [Toto Urinal with Automatic Flush Valve](https://gcsradheat.com/fixtures/flushing-urinal/toto/urinal-with-automatic-flush-valve/) | UE906EVG* | 0.5 GPF | 87.5% | 2 |
| [Willoughby Industries Ligature-Resistant Contoured High-Efficiency Urinals](https://gcsradheat.com/fixtures/flushing-urinal/willoughby-industries/ligature-resistant-contoured-high-efficiency-uri/) | ASUW-1314-HEU-BS | 0.5 GPF | 50.0% | 2 |
| [Zurn Z6001](https://gcsradheat.com/fixtures/flushing-urinal/zurn/z6001/) | Z6001-x-EWS-y | 0.5 GPF | 87.5% | 2 |

## When Should Homeowners Double-Check Fitment Before Installing Willoughby Industries Contoured High-Efficiency Urinals?

Low-flow fixtures save money across 4 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 50.0% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Installation & Code Questions for Willoughby Industries Contoured High-Efficiency Urinals

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Willoughby Industries Contoured High-Efficiency Urinals (UW-1317-HEU-BS) meet California Title 20 and federal WaterSense flow rules?

Partially—Willoughby Industries Contoured High-Efficiency Urinals carries EPA WaterSense certification at 0.5 GPF, which passes federal rules though states capping flow at 0.125 GPF require a lower-flow trim.

### What is the difference between trim variants listed under Willoughby Industries Contoured High-Efficiency Urinals?

All 4 consolidated SKUs share identical WaterSense hydraulic specs (0.5 GPF) and differ mainly by exterior finish, handle style, or packaging.

## Related Fixture & Plumbing Guides for Willoughby Industries

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Toto EcoPower→](https://gcsradheat.com/fixtures/flushing-urinal/toto/ecopower/)
- [Compare Toto Urinal with Automatic Flush Valve→](https://gcsradheat.com/fixtures/flushing-urinal/toto/urinal-with-automatic-flush-valve/)
- [Browse All WaterSense Flushing Urinals→](https://gcsradheat.com/fixtures/flushing-urinal/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installer note · UW-1317-HEU-BS

### Willoughby Industries Contoured High-Efficiency Urinals Fit Check

Confirm drain line slope, pressure balancing or supply stop sizes before installing a 0.5 GPF flushing urinal.
[All WaterSense Flushing Urinals](https://gcsradheat.com/fixtures/flushing-urinal/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)