title: "Avenue CTL-623A-YL Grant (Toilets)"
url: https://gcsradheat.com/fixtures/tank-type-toilet/avenue/grant/
description: "Avenue Grant (rep. SKU CTL-623A-YL) is an EPA WaterSense toilets series certified at 1.60 Full/0.80 Reduced (Dual-Flush) GPF, grouping 3 finish and trim."
---

EPA WaterSense toilets · Avenue (CTL-623A-YL)

# Avenue Grant WaterSense Toilet Specs (CTL-623A-YL)

Avenue Grant (rep. SKU CTL-623A-YL) is an EPA WaterSense toilets series certified at 1.60 Full/0.80 Reduced (Dual-Flush) GPF, grouping 3 finish and trim variants merged cleanly under this model platform. Compared to the federal 1.6 GPF limit, it trims water demand by 20.0% (~2,336 gal/yr in a 4-person home) and meets strict California Title 20 / CO / WA limits.

- **Certified Rating** : 1.60 Full/0.80 Reduced (Dual-Flush) GPF

- **EPAct Flow Savings** : 20.0%

- **Finish SKUs Merged** : 3

- **CA Title 20 Fit** : Compliant

- **Rep. SKU** : CTL-623A-YL

Flow savings & state code fit for Avenue Grant

Stepping down from federal 1.6 GPF hardware to 1.60 Full/0.80 Reduced (Dual-Flush) GPF on Avenue Grant delivers 20.0% lower usage per cycle—translating to 1,168 gal/yr saved for couples and 2,336 gal/yr for four-person households.

Dual hydraulic geometry (Gravity) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 3 consolidated trim SKUs.

## How Does Avenue Grant Compare to Federal 1.6 GPF Caps?

Core hydraulic measurements, strict state compliance status, and consolidated trim counts for the Avenue Grant platform (CTL-623A-YL) are audited below.

Verified EPA WaterSense & federal flow-rate benchmarks for Avenue Grant

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Avenue Grant | 807 cat. peers | Primary SKU: CTL-623A-YL |
| Rated Hydraulic Efficiency | 1.60 Full/0.80 Reduced (Dual-Flush) GPF | 1.6 GPF EPAct | 20.0% reduction vs federal ceiling |
| State Title 20 Status | Compliant | <= 1.28 GPF | Eligible in CA, CO, WA, NY & VT |
| Consolidated Trim Count | 3 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Dual | ASME A112.19.2 | Gravity |
| Matched Bowl / Tank SKUs | LL-623A-Y, LL-8359A-Y | CT-1031DF | Verify rough-in (10 or 12 in.) before purchase |

## How Much Water and Money Does Grant Save Annually?

Projected tap volume, sewer tariff, and hot water heating reductions below benchmark Avenue Grant against older EPAct baseline fixtures.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,168 gal/yr | $17/yr | $0/yr | **$17/yr** |
| 4-Person Family (US Avg Rate) | 2,336 gal/yr | $34/yr | $0/yr | **$34/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 2,336 gal/yr | $51/yr | $0/yr | **$51/yr** |
| 10-Year Cumulative Savings (4-Person) | 23,360 gal | $340 | $0 | **$340** |

## Which Trim SKUs Share the Avenue Grant Hydraulic Design?

We merged 3 finish or rough-in SKUs under this single Avenue engineering platform; up to 10 verified SKU codes are listed below.

Finish & trim SKUs sharing the Grant certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| CTL-623A-YL | Avenue Grant (Representative SKU) | 1.60 Full/0.80 Reduced (Dual-Flush) GPF | EPA WaterSense |
| CTL-8359A-YL | Avenue Grant (Alternate Trim / Rough-In) | 1.60 Full/0.80 Reduced (Dual-Flush) GPF | EPA WaterSense |
| TL-1261A-YL | Avenue Grant (Alternate Trim / Rough-In) | 1.60 Full/0.80 Reduced (Dual-Flush) GPF | EPA WaterSense |

## Which Toilets Series Compare Closest to Avenue Grant?

Compare four nearby WaterSense toilets series alongside rated flow, EPAct savings percentage, and trim counts.

Comparable WaterSense fixture series in WaterSense Tank-Type Toilets

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [American Standard Yorkville Vormax](https://gcsradheat.com/fixtures/tank-type-toilet/american-standard/yorkville-vormax/) | 209AA137.XXX | 1.28 GPF | 20.0% | 2 |
| [Avenue Eglinton](https://gcsradheat.com/fixtures/tank-type-toilet/avenue/eglinton/) | N/A | 1.28 GPF | 20.0% | 3 |
| [Avenue Grove](https://gcsradheat.com/fixtures/tank-type-toilet/avenue/grove/) | TL-1263A-YL | 1.28 GPF | 20.0% | 2 |
| [Axent Intelligent Toilet](https://gcsradheat.com/fixtures/tank-type-toilet/axent/intelligent-toilet/) | R60-E | 1.00 GPF | 37.5% | 3 |

## When Should Homeowners Double-Check Fitment Before Installing Avenue Grant?

Low-flow fixtures save money across 3 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 20.0% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Installation & Code Questions for Avenue Grant

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Avenue Grant (CTL-623A-YL) meet California Title 20 and federal WaterSense flow rules?

Yes—Avenue Grant carries EPA WaterSense certification at 1.60 Full/0.80 Reduced (Dual-Flush) GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

### What is the difference between trim variants listed under Avenue Grant?

All 3 consolidated SKUs share identical WaterSense hydraulic specs (1.60 Full/0.80 Reduced (Dual-Flush) GPF) and differ mainly by exterior finish, handle style, or packaging.

## Related Fixture & Plumbing Guides for Avenue

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American Standard Yorkville Vormax→](https://gcsradheat.com/fixtures/tank-type-toilet/american-standard/yorkville-vormax/)
- [Compare Avenue Eglinton→](https://gcsradheat.com/fixtures/tank-type-toilet/avenue/eglinton/)
- [Browse All WaterSense Toilets→](https://gcsradheat.com/fixtures/tank-type-toilet/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installer note · CTL-623A-YL

### Avenue Grant Fit Check

Confirm drain line slope, pressure balancing or supply stop sizes before installing a 1.60 Full/0.80 Reduced (Dual-Flush) GPF toilet.
[All WaterSense Tank-Type Toilets](https://gcsradheat.com/fixtures/tank-type-toilet/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)