---
title: "CANTON 572-6794 & 572-6193 572-6193 (Toilets)"
url: https://gcsradheat.com/fixtures/tank-type-toilet/canton/572-6193/
description: "CANTON 572-6193 (rep. SKU 572-6794 & 572-6193) is an EPA WaterSense toilets series certified at 1.28 GPF, grouping 4 finish and trim variants merged cleanly."
---

EPA WaterSense toilets · CANTON (572-6794 & 572-6193)

# CANTON 572-6193 WaterSense Toilet Specs (572-6794 & 572-6193)

CANTON 572-6193 (rep. SKU 572-6794 & 572-6193) is an EPA WaterSense toilets series certified at 1.28 GPF, grouping 4 finish and trim variants merged cleanly under this model platform. Compared to the federal 1.6 GPF limit, it trims water demand by 20.0% (~2,336 gal/yr in a 4-person home) and meets strict California Title 20 / CO / WA limits.

- **Certified Rating** : 1.28 GPF

- **EPAct Flow Savings** : 20.0%

- **Finish SKUs Merged** : 4

- **CA Title 20 Fit** : Compliant

- **Rep. SKU** : 572-6794 & 572-6193

Flow savings & state code fit for CANTON 572-6193

Stepping down from federal 1.6 GPF hardware to 1.28 GPF on CANTON 572-6193 delivers 20.0% lower usage per cycle—translating to 1,168 gal/yr saved for couples and 2,336 gal/yr for four-person households.

Single hydraulic geometry (Gravity) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 4 consolidated trim SKUs.

## How Does CANTON 572-6193 Compare to Federal 1.6 GPF Caps?

Core hydraulic measurements, strict state compliance status, and consolidated trim counts for the CANTON 572-6193 platform (572-6794 & 572-6193) are audited below.

Verified EPA WaterSense & federal flow-rate benchmarks for CANTON 572-6193

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | CANTON 572-6193 | 807 cat. peers | Primary SKU: 572-6794 & 572-6193 |
| Rated Hydraulic Efficiency | 1.28 GPF | 1.6 GPF EPAct | 20.0% reduction vs federal ceiling |
| State Title 20 Status | Compliant | <= 1.28 GPF | Eligible in CA, CO, WA, NY & VT |
| Consolidated Trim Count | 4 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Single | ASME A112.19.2 | Gravity |
| Matched Bowl / Tank SKUs | 572-6193 | 572-6794, 572-6195, 572-6196, 572-6191 | Verify rough-in (10 or 12 in.) before purchase |

## How Much Water and Money Does 572-6193 Save Annually?

Projected tap volume, sewer tariff, and hot water heating reductions below benchmark CANTON 572-6193 against older EPAct baseline fixtures.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,168 gal/yr | $17/yr | $0/yr | **$17/yr** |
| 4-Person Family (US Avg Rate) | 2,336 gal/yr | $34/yr | $0/yr | **$34/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 2,336 gal/yr | $51/yr | $0/yr | **$51/yr** |
| 10-Year Cumulative Savings (4-Person) | 23,360 gal | $340 | $0 | **$340** |

## Which Trim SKUs Share the CANTON 572-6193 Hydraulic Design?

We merged 4 finish or rough-in SKUs under this single CANTON engineering platform; up to 10 verified SKU codes are listed below.

Finish & trim SKUs sharing the 572-6193 certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| 572-6794 & 572-6193 | CANTON 572-6193 (Representative SKU) | 1.28 GPF | EPA WaterSense |
| N/A | CANTON 572-6193 (Alternate Trim / Rough-In) | 1.28 GPF | EPA WaterSense |

## Which Toilets Series Compare Closest to CANTON 572-6193?

Compare four nearby WaterSense toilets series alongside rated flow, EPAct savings percentage, and trim counts.

Comparable WaterSense fixture series in WaterSense Tank-Type Toilets

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [CANTON 572-5789](https://gcsradheat.com/fixtures/tank-type-toilet/canton/572-5789/) | 572-6234 & 572-5789 | 1.28 GPF | 20.0% | 2 |
| [CANTON 572-6192](https://gcsradheat.com/fixtures/tank-type-toilet/canton/572-6192/) | 572-6794 & 572-6192 | 1.28 GPF | 20.0% | 4 |
| [CANTON 572-6194](https://gcsradheat.com/fixtures/tank-type-toilet/canton/572-6194/) | 572-6794 & 572-6194 | 1.28 GPF | 20.0% | 4 |
| [Caroma Bondi 270 Easy Height](https://gcsradheat.com/fixtures/tank-type-toilet/caroma/bondi-270-easy-height/) | N/A | 1.60 Full/0.90 Reduced (Dual-Flush) GPF | 0.0% | 2 |

## When Should Homeowners Double-Check Fitment Before Installing CANTON 572-6193?

Low-flow fixtures save money across 4 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 20.0% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Installation & Code Questions for CANTON 572-6193

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does CANTON 572-6193 (572-6794 & 572-6193) meet California Title 20 and federal WaterSense flow rules?

Yes—CANTON 572-6193 carries EPA WaterSense certification at 1.28 GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

### What is the difference between trim variants listed under CANTON 572-6193?

All 4 consolidated SKUs share identical WaterSense hydraulic specs (1.28 GPF) and differ mainly by exterior finish, handle style, or packaging.

## Related Fixture & Plumbing Guides for CANTON

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare CANTON 572-5789→](https://gcsradheat.com/fixtures/tank-type-toilet/canton/572-5789/)
- [Compare CANTON 572-6192→](https://gcsradheat.com/fixtures/tank-type-toilet/canton/572-6192/)
- [Browse All WaterSense Toilets→](https://gcsradheat.com/fixtures/tank-type-toilet/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installer note · 572-6794 & 572-6193

### CANTON 572-6193 Fit Check

Confirm drain line slope, pressure balancing or supply stop sizes before installing a 1.28 GPF toilet.
[All WaterSense Tank-Type Toilets](https://gcsradheat.com/fixtures/tank-type-toilet/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)
