title: "Globe Union DF-20-117 SE-21-128 (Toilets)"
url: https://gcsradheat.com/fixtures/tank-type-toilet/globe-union/se-21-128/
description: "Engineered as a WaterSense-listed toilets series, Globe Union SE-21-128 (starting at DF-20-117) operates at 1.60 Full/1.10 Reduced (Dual-Flush) GPF across 3."
---

Canonical series spec · Globe Union DF-20-117

# Globe Union SE-21-128 WaterSense Toilet Specs (DF-20-117)

Engineered as a WaterSense-listed toilets series, Globe Union SE-21-128 (starting at DF-20-117) operates at 1.60 Full/1.10 Reduced (Dual-Flush) GPF across 3 finish and trim variants merged cleanly under this model platform. Replacing a standard 1.6 GPF unit saves 0.0% annually on tap volume; performance passes federal WaterSense, though exceeds California Title 20 (1.28 GPF).

- **Certified Rating** : 1.60 Full/1.10 Reduced (Dual-Flush) GPF

- **EPAct Flow Savings** : 0.0%

- **Finish SKUs Merged** : 3

- **CA Title 20 Fit** : Federal Only

- **Rep. SKU** : DF-20-117

Plumbing impact — SE-21-128

Stepping down from federal 1.6 GPF hardware to 1.60 Full/1.10 Reduced (Dual-Flush) GPF on Globe Union SE-21-128 delivers 0.0% lower usage per cycle—translating to 0 gal/yr saved for couples and 0 gal/yr for four-person households.

Dual hydraulic geometry (Gravity) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 3 consolidated trim SKUs.

## Is Globe Union SE-21-128 Compliant With 2026 State Flow Caps?

Check federal EPAct ceilings versus strict California Title 20, Colorado, Washington, and New York flow limits for Globe Union SE-21-128 (DF-20-117) in this specification audit.

Verified EPA WaterSense & federal flow-rate benchmarks for Globe Union SE-21-128

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Globe Union SE-21-128 | 807 cat. peers | Primary SKU: DF-20-117 |
| Rated Hydraulic Efficiency | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | 1.6 GPF EPAct | 0.0% reduction vs federal ceiling |
| State Title 20 Status | Exceeds Strict State Cap | <= 1.28 GPF | Installable outside 1.28/1.8/1.2 cap states |
| Consolidated Trim Count | 3 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Dual | ASME A112.19.2 | Gravity |
| Matched Bowl / Tank SKUs | SE-21-128 | DF-28-195, DF-28-190, DF-28-192 | Verify rough-in (10 or 12 in.) before purchase |

## What Does Globe Union SE-21-128 Save Over 10 Years?

Cumulative decade savings below quantify avoided tap gallons and combined utility bills when stepping down older fixtures to 1.60 Full/1.10 Reduced (Dual-Flush) GPF.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 0 gal/yr | $0/yr | $0/yr | **$0/yr** |
| 4-Person Family (US Avg Rate) | 0 gal/yr | $0/yr | $0/yr | **$0/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 0 gal/yr | $0/yr | $0/yr | **$0/yr** |
| 10-Year Cumulative Savings (4-Person) | 0 gal | $0 | $0 | **$0** |

## Which Representative SKUs Are Covered Under SE-21-128?

Verify representative model numbers, finish codes, and certified flow ratings consolidated cleanly under the Globe Union SE-21-128 EPA WaterSense product certificate below.

Finish & trim SKUs sharing the SE-21-128 certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| DF-20-117 | Globe Union SE-21-128 (Representative SKU) | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | EPA WaterSense |
| DF-20-118 | Globe Union SE-21-128 (Alternate Trim / Rough-In) | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | EPA WaterSense |
| DF-20-118(INSULATED) | Globe Union SE-21-128 (Alternate Trim / Rough-In) | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | EPA WaterSense |

## What Comparable Toilets Models Should You Cross-Shop?

Evaluate four comparable WaterSense toilets series ranked nearby in our catalog before finalizing valve compatibility or rough-in orders.

Comparable WaterSense fixture series in WaterSense Tank-Type Toilets

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Globe Union GWS21528](https://gcsradheat.com/fixtures/tank-type-toilet/globe-union/gws21528/) | GLF20517(LF-20-517) | 0.80 GPF | 50.0% | 2 |
| [Globe Union MAXWELL®](https://gcsradheat.com/fixtures/tank-type-toilet/globe-union/maxwell/) | DF-20-102(GDF20102)(INSULATED) | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | 0.0% | 2 |
| [Globe Union ULTRA FLUSH®](https://gcsradheat.com/fixtures/tank-type-toilet/globe-union/ultra-flush/) | GHE20300(HE-20-300) | 1.28 GPF | 20.0% | 12 |
| [Globe Union VIPER®](https://gcsradheat.com/fixtures/tank-type-toilet/globe-union/viper/) | C211132** | 1.28 GPF | 37.5% | 5 |

## When Should Homeowners Double-Check Fitment Before Installing Globe Union SE-21-128?

Low-flow fixtures save money across 3 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 0.0% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Homeowner & Contractor Questions: SE-21-128

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Globe Union SE-21-128 (DF-20-117) meet California Title 20 and federal WaterSense flow rules?

Partially—Globe Union SE-21-128 carries EPA WaterSense certification at 1.60 Full/1.10 Reduced (Dual-Flush) GPF, which passes federal rules though states capping flow at 1.28 GPF require a lower-flow trim.

### What is the difference between trim variants listed under Globe Union SE-21-128?

All 3 consolidated SKUs share identical WaterSense hydraulic specs (1.60 Full/1.10 Reduced (Dual-Flush) GPF) and differ mainly by exterior finish, handle style, or packaging.

## More Toilets & Plumbing Standards

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Globe Union GWS21528→](https://gcsradheat.com/fixtures/tank-type-toilet/globe-union/gws21528/)
- [Compare Globe Union MAXWELL®→](https://gcsradheat.com/fixtures/tank-type-toilet/globe-union/maxwell/)
- [Browse All WaterSense Toilets→](https://gcsradheat.com/fixtures/tank-type-toilet/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Toilets Fit

### 3 Trim SKUs Consolidated

Confirm valve stem compatibility or porcelain rough-in clearances prior to ordering DF-20-117.
[All WaterSense Tank-Type Toilets](https://gcsradheat.com/fixtures/tank-type-toilet/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)