# Niagara N2430RB WaterSense Toilet Specs (N2430R)

Niagara N2430RB (rep. SKU N2430R) is an EPA WaterSense toilets series certified at 1.28 Full/1.00 Reduced (Dual-Flush) GPF, grouping 2 finish and trim variants merged cleanly under this model platform. Compared to the federal 1.6 GPF limit, it trims water demand by 20.0% (~2,336 gal/yr in a 4-person home) and meets strict California Title 20 / CO / WA limits.

- **Certified Rating** : 1.28 Full/1.00 Reduced (Dual-Flush) GPF

- **EPAct Flow Savings** : 20.0%

- **Finish SKUs Merged** : 2

- **CA Title 20 Fit** : Compliant

- **Rep. SKU** : N2430R

Flow savings & state code fit for Niagara N2430RB

Stepping down from federal 1.6 GPF hardware to 1.28 Full/1.00 Reduced (Dual-Flush) GPF on Niagara N2430RB delivers 20.0% lower usage per cycle—translating to 1,168 gal/yr saved for couples and 2,336 gal/yr for four-person households.

Dual hydraulic geometry (Gravity) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 2 consolidated trim SKUs.

## How Does Niagara N2430RB Compare to Federal 1.6 GPF Caps?

Core hydraulic measurements, strict state compliance status, and consolidated trim counts for the Niagara N2430RB platform (N2430R) are audited below.

Verified EPA WaterSense & federal flow-rate benchmarks for Niagara N2430RB

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Niagara N2430RB | 807 cat. peers | Primary SKU: N2430R |
| Rated Hydraulic Efficiency | 1.28 Full/1.00 Reduced (Dual-Flush) GPF | 1.6 GPF EPAct | 20.0% reduction vs federal ceiling |
| State Title 20 Status | Compliant | <= 1.28 GPF | Eligible in CA, CO, WA, NY & VT |
| Consolidated Trim Count | 2 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Dual | ASME A112.19.2 | Gravity |
| Matched Bowl / Tank SKUs | N2430RB | N2430T, N2430T-SF | Verify rough-in (10 or 12 in.) before purchase |

## How Much Water and Money Does N2430RB Save Annually?

Projected tap volume, sewer tariff, and hot water heating reductions below benchmark Niagara N2430RB against older EPAct baseline fixtures.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 1,168 gal/yr | $17/yr | $0/yr | **$17/yr** |
| 4-Person Family (US Avg Rate) | 2,336 gal/yr | $34/yr | $0/yr | **$34/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 2,336 gal/yr | $51/yr | $0/yr | **$51/yr** |
| 10-Year Cumulative Savings (4-Person) | 23,360 gal | $340 | $0 | **$340** |

## Which Trim SKUs Share the Niagara N2430RB Hydraulic Design?

We merged 2 finish or rough-in SKUs under this single Niagara engineering platform; up to 10 verified SKU codes are listed below.

Finish & trim SKUs sharing the N2430RB certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| N2430R | Niagara N2430RB (Representative SKU) | 1.28 Full/1.00 Reduced (Dual-Flush) GPF | EPA WaterSense |
| N2430R-SF | Niagara N2430RB (Alternate Trim / Rough-In) | 1.28 Full/1.00 Reduced (Dual-Flush) GPF | EPA WaterSense |

## Which Toilets Series Compare Closest to Niagara N2430RB?

Compare four nearby WaterSense toilets series alongside rated flow, EPAct savings percentage, and trim counts.

Comparable WaterSense fixture series in WaterSense Tank-Type Toilets

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Niagara N2316RB-10](https://gcsradheat.com/fixtures/tank-type-toilet/niagara/n2316rb-10/) | N2316R-10 | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | 20.0% | 2 |
| [Niagara N2430EB](https://gcsradheat.com/fixtures/tank-type-toilet/niagara/n2430eb/) | N2430E* | 1.28 Full/1.00 Reduced (Dual-Flush) GPF | 20.0% | 2 |
| [Niagara Phantom](https://gcsradheat.com/fixtures/tank-type-toilet/niagara/phantom/) | 33.1010.01LWH | 0.80 GPF | 50.0% | 2 |
| [Niagara Power Flush](https://gcsradheat.com/fixtures/tank-type-toilet/niagara/power-flush/) | N2450E*-19 | 1.28 GPF | 20.0% | 8 |

## When Should Homeowners Double-Check Fitment Before Installing Niagara N2430RB?

Low-flow fixtures save money across 2 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 20.0% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Installation & Code Questions for Niagara N2430RB

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Niagara N2430RB (N2430R) meet California Title 20 and federal WaterSense flow rules?

Yes—Niagara N2430RB carries EPA WaterSense certification at 1.28 Full/1.00 Reduced (Dual-Flush) GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

### What is the difference between trim variants listed under Niagara N2430RB?

All 2 consolidated SKUs share identical WaterSense hydraulic specs (1.28 Full/1.00 Reduced (Dual-Flush) GPF) and differ mainly by exterior finish, handle style, or packaging.

## Related Fixture & Plumbing Guides for Niagara

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Niagara N2316RB-10→](https://gcsradheat.com/fixtures/tank-type-toilet/niagara/n2316rb-10/)
- [Compare Niagara N2430EB→](https://gcsradheat.com/fixtures/tank-type-toilet/niagara/n2430eb/)
- [Browse All WaterSense Toilets→](https://gcsradheat.com/fixtures/tank-type-toilet/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installer note · N2430R

### Niagara N2430RB Fit Check

Confirm drain line slope, pressure balancing or supply stop sizes before installing a 1.28 Full/1.00 Reduced (Dual-Flush) GPF toilet.
[All WaterSense Tank-Type Toilets](https://gcsradheat.com/fixtures/tank-type-toilet/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)