---
title: "Sloan WETS-8009.8010 ST-8009 (Toilets)"
url: https://gcsradheat.com/fixtures/tank-type-toilet/sloan/st-8009/
description: "Consolidating 4 finish and trim variants merged cleanly under this model platform, Sloan's ST-8009 (WETS-8009.8010) delivers a verified 1.28 GPF flow rating in."
---

WaterSense verified · Sloan WETS-8009.8010

# Sloan ST-8009 WaterSense Toilet Specs (WETS-8009.8010)

Consolidating 4 finish and trim variants merged cleanly under this model platform, Sloan's ST-8009 (WETS-8009.8010) delivers a verified 1.28 GPF flow rating in the toilets category. That yields a 37.5% reduction below federal EPAct baselines (~2,190–4,380 gal saved yearly) and meets strict California Title 20 / CO / WA limits. Inspect full SKU variations, regional bill savings across 2-person and 4-person homes, and 807 peer toilets series below.

- **Certified Rating** : 1.28 GPF

- **EPAct Flow Savings** : 37.5%

- **Finish SKUs Merged** : 4

- **CA Title 20 Fit** : Compliant

- **Rep. SKU** : WETS-8009.8010

Efficiency breakdown — Sloan ST-8009

Stepping down from federal 1.6 GPF hardware to 1.28 GPF on Sloan ST-8009 delivers 37.5% lower usage per cycle—translating to 2,190 gal/yr saved for couples and 4,380 gal/yr for four-person households.

Single hydraulic geometry (Pressure Assist) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 4 consolidated trim SKUs.

## Which Hydraulic Specs Define Sloan ST-8009 (WETS-8009.8010)?

Inspect certified flow rating, federal baseline gap, strict California Title 20 status, and consolidation counts across the Sloan ST-8009 product series below.

Verified EPA WaterSense & federal flow-rate benchmarks for Sloan ST-8009

| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Sloan ST-8009 | 807 cat. peers | Primary SKU: WETS-8009.8010 |
| Rated Hydraulic Efficiency | 1.28 GPF | 1.6 GPF EPAct | 37.5% reduction vs federal ceiling |
| State Title 20 Status | Compliant | <= 1.28 GPF | Eligible in CA, CO, WA, NY & VT |
| Consolidated Trim Count | 4 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Single | ASME A112.19.2 | Pressure Assist |
| Matched Bowl / Tank SKUs | ST-8009 | ST-8010, ST-8016, ST-8110, ST-8116 | Verify rough-in (10 or 12 in.) before purchase |

## How Rapidly Does ST-8009 Cut Household Water Bills?

Lower gallon usage reduces both municipal meter bills and water heating fuel loads—compare multi-year household cost scenarios for WETS-8009.8010 below.

Projected annual water, sewer, and heating savings versus federal baseline fixtures

| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 2,190 gal/yr | $32/yr | $0/yr | **$32/yr** |
| 4-Person Family (US Avg Rate) | 4,380 gal/yr | $64/yr | $0/yr | **$64/yr** |
| 4-Person Family (High-Rate Metro, 1.5x) | 4,380 gal/yr | $96/yr | $0/yr | **$96/yr** |
| 10-Year Cumulative Savings (4-Person) | 43,800 gal | $640 | $0 | **$640** |

## How Many Finish Variants Map to Sloan ST-8009?

Instead of repeating thin duplicate pages for identical internal valves, 4 verified Sloan hardware configurations roll up cleanly into this single benchmark.

Finish & trim SKUs sharing the ST-8009 certified hydraulic design

| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| WETS-8009.8010 | Sloan ST-8009 (Representative SKU) | 1.28 GPF | EPA WaterSense |
| WETS-8009.8016 | Sloan ST-8009 (Alternate Trim / Rough-In) | 1.28 GPF | EPA WaterSense |
| WETS-8009.8110 | Sloan ST-8009 (Alternate Trim / Rough-In) | 1.28 GPF | EPA WaterSense |
| WETS-8009.8116 | Sloan ST-8009 (Alternate Trim / Rough-In) | 1.28 GPF | EPA WaterSense |

## Which Peer WaterSense Series Offer Similar Output?

Four competing WaterSense toilets alternatives sit alongside Sloan ST-8009 in the sortable comparison matrix below for side-by-side homeowner vetting.

Comparable WaterSense fixture series in WaterSense Tank-Type Toilets

| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| [Simas Spa Baden Baden](https://gcsradheat.com/fixtures/tank-type-toilet/simas-spa/baden-baden/) | BB01 | 1.60 Full/0.80 Reduced (Dual-Flush) GPF | 0.0% | 2 |
| [Simas Spa Vignoni](https://gcsradheat.com/fixtures/tank-type-toilet/simas-spa/vignoni/) | VI01 | 1.60 Full/0.80 Reduced (Dual-Flush) GPF | 0.0% | 2 |
| [Sloan ST-8029](https://gcsradheat.com/fixtures/tank-type-toilet/sloan/st-8029/) | WETS-8029.8016 | 1.00 GPF | 37.5% | 3 |
| [Sloan ST4009](https://gcsradheat.com/fixtures/tank-type-toilet/sloan/st4009/) | WETS-4009.4010 | 1.28 GPF | 31.2% | 8 |

## When Should Homeowners Double-Check Fitment Before Installing Sloan ST-8009?

Low-flow fixtures save money across 4 finish trims, but existing drain piping and static water pressure still govern real-world performance.

### Key Limitations & Exclusions

- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

### Which Option Fits Your Situation?

**Post-1990 Copper or PEX Supply Lines** Strong Fit — full flow performance and 37.5% bill reduction with clean drain slope.

**Pre-1970 Cast-Iron Sewer Laterals** Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

## Key Homeowner Answers for Sloan WETS-8009.8010

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Sloan ST-8009 (WETS-8009.8010) meet California Title 20 and federal WaterSense flow rules?

Yes—Sloan ST-8009 carries EPA WaterSense certification at 1.28 GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

### What is the difference between trim variants listed under Sloan ST-8009?

All 4 consolidated SKUs share identical WaterSense hydraulic specs (1.28 GPF) and differ mainly by exterior finish, handle style, or packaging.

## Cartridge, Hardness & Softener Guides

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Simas Spa Baden Baden→](https://gcsradheat.com/fixtures/tank-type-toilet/simas-spa/baden-baden/)
- [Compare Simas Spa Vignoni→](https://gcsradheat.com/fixtures/tank-type-toilet/simas-spa/vignoni/)
- [Browse All WaterSense Toilets→](https://gcsradheat.com/fixtures/tank-type-toilet/)
- [Check Complete WaterSense Series Index→](https://gcsradheat.com/fixtures/)
- [Decode Shower & Faucet Cartridge Stems→](https://gcsradheat.com/parts-cartridges/)

## Sources

1. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Spec Snapshot · Sloan

### 1.28 GPF Output

Cuts tap demand by 37.5% over baseline units across 4 finish options.
[All WaterSense Tank-Type Toilets](https://gcsradheat.com/fixtures/tank-type-toilet/) [EPA WaterSense Overview](https://gcsradheat.com/watersense/)
