# Delta RP25513 Two-Handle Stem Assembly with RP4993 Seats & Springs

Designed for Two-handle Delta bathroom, kitchen, and laundry faucets, Delta RP25513 uses Quarter-turn stop rotation (1/4 turn hot/cold) action with Threaded brass bonnet nut over stem collar. Always replace RP4993 seats/springs simultaneously; not for DST ceramic faucets. Verify exact stem geometry (D-shaped brass stem shaft with quarter-turn stop plate) and shut off hot and cold isolation stops before removing retaining clips.

- **OEM Part Number**: RP25513

- **Operating / Join Action**: Quarter-turn stop rotation

- **Retainer / Seal Style**: Threaded brass bonnet nut over stem collar

- **Compatible Series**: 1 Platform

Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip

How to tell this part apart

Mechanical checks for Delta RP25513: motion — Quarter-turn stop rotation (1/4 turn hot/cold); retainer — Threaded brass bonnet nut over stem collar. Stem cue: D-shaped brass stem shaft with quarter-turn stop plate.

Always replace RP4993 seats/springs simultaneously; not for DST ceramic faucets.

## How Do You Identify the Delta RP25513 Retainer?

Verify handle motion (Quarter-turn stop rotation) and retaining hardware (Threaded brass bonnet nut over stem collar) under the trim plate before pulling the cartridge or shutting off supply stops.

Mechanical retainer anatomy: verify retainer style and handle action (rotate-only vs. pull-turn) before shutting water off or ordering OEM cartridges.

## What Valves Fit Delta RP25513?

Review complete OEM fitment specifications, body construction, non-interchangeable warnings, and federal WaterSense flow ceilings (45,604 certified fixtures) for RP25513 below.

Verified OEM technical attributes for Delta RP25513

| Attribute | Verified Specification |
|---|---|
| Primary Application | Two-handle Delta bathroom, kitchen, and laundry faucets |
| Handle Action | Quarter-turn stop rotation (1/4 turn hot/cold) |
| Retainer Mechanism | Threaded brass bonnet nut over stem collar |
| Body & Seal Construction | Brass/polymer stem paired with rubber RP4993 cup seats and stainless springs |
| Stem / Fitment Note | D-shaped brass stem shaft with quarter-turn stop plate |
| Compatible Valve Platforms | Delta 2500, 2100, 3500 two-handle lavatory and kitchen platforms |
| Non-Interchangeable Warning | Always replace RP4993 seats/springs simultaneously; not for DST ceramic faucets. |
| Federal Fixture Flow Rules | Faucets ≤2.2 gpm @ 60 psi under 10 CFR 430.32(o); WaterSense ≤1.5 gpm across 45,604 certified fixtures |

## How Does RP25513 Compare to Peer OEM Parts?

Cross-check 6 adjacent residential OEM shower cartridges, push-to-connect couplings, and RPZ backflow repair assemblies to avoid incompatible part orders.

Cross-reference matrix of indexed residential OEM cartridges, connectors, and backflow kits

| Brand & Part # | Application | Handle / Join Action | Retainer Mechanism |
|---|---|---|---|
| [Delta RP46074](https://gcsradheat.com/parts/delta/delta-rp46074-multichoice/) | Post-2007 Delta 13/14 Series MultiChoice shower valves | Rotate-only single handle | Large threaded chrome/brass bonnet nut over valve body |
| [Delta RP19804](https://gcsradheat.com/parts/delta/delta-rp19804-legacy/) | Pre-2007 Monitor 1300 and 1400 tub/shower valves | Rotate-only single lever | Threaded bonnet nut |
| [Delta RP46463](https://gcsradheat.com/parts/delta/delta-rp46463-multichoice-17/) | Post-2006 Delta 17 Series dual-handle shower valves | Dual-function: outer paddle controls volume, inner knob sets temperature | Threaded MultiChoice R10000 chrome/brass bonnet nut |
| [Delta RP32104](https://gcsradheat.com/parts/delta/delta-rp32104-legacy-1700/) | Pre-2006 Delta Monitor 1700 dual-control shower valves | Dual concentric lever | Threaded brass bonnet nut |
| [Delta RP50587](https://gcsradheat.com/parts/delta/delta-rp50587-diamond-seal/) | Delta DST single-handle kitchen and lavatory faucets | Single lever lift-for-volume and tilt-left/right for temperature | Threaded brass/polymer retaining nut + cap |
| [Delta RP70 / RP3614](https://gcsradheat.com/parts/delta/delta-rp70-ball-valve/) | Legacy Delta ball-handle kitchen and 600 Series valves | Joystick ball motion | Threaded chrome adjusting ring + slotted cam cap |

## What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Which rough-in valves fit Delta RP25513?

Delta RP25513 fits Delta 2500, 2100, 3500 two-handle lavatory and kitchen platforms. Cross-check Brass/polymer stem paired with rubber RP4993 cup seats and stainless springs before ordering.

### How do I identify Delta RP25513 without removing it first?

Test handle motion (Quarter-turn stop rotation (1/4 turn hot/cold)) and inspect under the sleeve for Threaded brass bonnet nut over stem collar.

### Where do the engineering metrics for Delta RP25513 originate?

Data provenance for Delta RP25513 links straight to verified agency releases and OEM installation bulletins. Confirmed fitment applies across Delta 2500, 2100, 3500 two-handle lavatory and kitchen platforms.

### When should homeowners stop and call 911 or a pro on Delta RP25513?

Online tables clarify baseline engineering limits, not site-specific hazards like live gas odors or corroded service mains. Shut off house or local isolation valves and release pressure before removing retaining clips or bonnet nuts.

### Which federal regulatory baselines intersect with Delta RP25513?

Check local Authority Having Jurisdiction amendments to IPC/UPC codes alongside federal EPA drinking water and 10 CFR 430 efficiency mandates.

### Which incentives remain open in 2026 for plumbing equipment?

Verify active state DOE HEAR allocations (up to $1,750 for heat pump water heaters) and local utility rebates following the Dec 31, 2025 25C expiration.

### When should a homeowner escalate Delta RP25513 to a state-licensed plumber?

Escalate whenever tasks involve fuel-gas piping, Category IV exhaust venting, 240V electrical circuits, main shutoff valves, or permitted sewer excavations.

### Does TapAndPipe accept paid placements inside Delta RP25513?

No. All specifications, state benchmarks, and contractor lists derive strictly from official public records and OEM manuals with zero paid ranking boosts.

## Which Related Cartridges and Wizards Should You Check?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Launch Photo-Less Cartridge Identifier Wizard→](https://gcsradheat.com/tools/cartridge-pipe-identifier/)
- [Open Moen Shower Cartridge Technical Comparison→](https://gcsradheat.com/compare/moen-1222-vs-1225-vs-1255/)
- [Open Delta MultiChoice Cartridge Comparison→](https://gcsradheat.com/compare/delta-rp46074-vs-rp19804/)
- [Compare Delta RP70 / RP3614→](https://gcsradheat.com/parts/delta/delta-rp70-ball-valve/)
- [Compare Kohler GP876851→](https://gcsradheat.com/parts/kohler/kohler-gp876851-rite-temp-k8304/)

## Sources

1. [Delta Faucet MultiChoice Universal Valve & Cartridge Compatibility Guide](https://www.deltafaucet.com/customersupport) — Delta Faucet Company (Masco), Delta MultiChoice R10000 Tech Sheet (retrieved 2026-11-23)
2. [ASTM B88 Copper Water Tube & ASME B1.20.1 Pipe Threads](https://www.astm.org/b0088-22.html) — ASTM International & ASME, ASTM B88 / F876 / ASME B1.20.1 (retrieved 2026-11-23)
3. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
4. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)

Safe removal reminder

Always shut off both hot and cold isolation stops and relieve water pressure before removing retainer clips or bonnet nuts.
[Launch Cartridge Wizard](https://gcsradheat.com/tools/cartridge-pipe-identifier/)