# Pfister 910-0300 Reversible Ceramic Disc Stem Cartridge

OEM specification for Pfister 910-0300: built for Pfister two-handle bathroom widespread, centerset, and Roman tub faucets (Brass housing with ceramic discs and lower EPDM seat washer), identifiable by Quarter-turn 90-degree rotation (reversible hot/cold stop). Verify exact stem geometry (12-point spline broach with reversible plastic stop clip) and shut off hot and cold isolation stops before removing retaining clips.

- **OEM Part Number**: 910-0300

- **Operating / Join Action**: Quarter-turn 90-degree rotation

- **Retainer / Seal Style**: Threaded brass stem nut

- **Compatible Series**: 1 Platform

Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip

How to tell this part apart

Mechanical checks for Pfister 910-0300: motion — Quarter-turn 90-degree rotation (reversible hot/cold stop); retainer — Threaded brass stem nut. Stem cue: 12-point spline broach with reversible plastic stop clip.

Not interchangeable with older compression washer stems (910-374 / 910-385).

## How Do You Identify the Pfister 910-0300 Retainer?

Verify handle motion (Quarter-turn 90-degree rotation) and retaining hardware (Threaded brass stem nut) under the trim plate before pulling the cartridge or shutting off supply stops.

Mechanical retainer anatomy: verify retainer style and handle action (rotate-only vs. pull-turn) before shutting water off or ordering OEM cartridges.

## What Valves Fit Pfister 910-0300?

Review complete OEM fitment specifications, body construction, non-interchangeable warnings, and federal WaterSense flow ceilings (45,604 certified fixtures) for 910-0300 below.

Verified OEM technical attributes for Pfister 910-0300

| Attribute | Verified Specification |
|---|---|
| Primary Application | Pfister two-handle bathroom widespread, centerset, and Roman tub faucets |
| Handle Action | Quarter-turn 90-degree rotation (reversible hot/cold stop) |
| Retainer Mechanism | Threaded brass stem nut |
| Body & Seal Construction | Brass housing with ceramic discs and lower EPDM seat washer |
| Stem / Fitment Note | 12-point spline broach with reversible plastic stop clip |
| Compatible Valve Platforms | Pfister Bedford, Pasadena, Kenzo, Contempra two-handle faucets |
| Non-Interchangeable Warning | Not interchangeable with older compression washer stems (910-374 / 910-385). |
| Federal Fixture Flow Rules | Faucets ≤2.2 gpm @ 60 psi under 10 CFR 430.32(o); WaterSense ≤1.5 gpm across 45,604 certified fixtures |

## How Does 910-0300 Compare to Peer OEM Parts?

Cross-check 6 adjacent residential OEM shower cartridges, push-to-connect couplings, and RPZ backflow repair assemblies to avoid incompatible part orders.

Cross-reference matrix of indexed residential OEM cartridges, connectors, and backflow kits

| Brand & Part # | Application | Handle / Join Action | Retainer Mechanism |
|---|---|---|---|
| [Pfister 974-0420 / 974-5319](https://gcsradheat.com/parts/pfister/pfister-974-042-pressure-balance/) | Pfister 0X8 / JX8 single-handle shower valves | Rotate-only single lever | 4-screw retainer collar or threaded nut |
| [Moen 1222](https://gcsradheat.com/parts/moen/moen-1222-posi-temp/) | Posi-Temp tub and shower pressure-balancing valves | Rotate-only | Vertical wire/U-clip inserted through top of brass valve body |
| [Moen 1225](https://gcsradheat.com/parts/moen/moen-1225-magnum/) | Single-handle kitchen, bath, and Chateau shower faucets | Pull out for volume, turn left/right for temperature | Top brass/wire retainer clip behind escutcheon sleeve |
| [Moen 1255](https://gcsradheat.com/parts/moen/moen-1255-duralast/) | Post-2009 single-handle kitchen and bath sink faucets | Lift/tilt lever forward-back + swivel left-right | Threaded plastic locking nut |
| [Delta RP46074](https://gcsradheat.com/parts/delta/delta-rp46074-multichoice/) | Post-2007 Delta 13/14 Series MultiChoice shower valves | Rotate-only single handle | Large threaded chrome/brass bonnet nut over valve body |
| [Delta RP19804](https://gcsradheat.com/parts/delta/delta-rp19804-legacy/) | Pre-2007 Monitor 1300 and 1400 tub/shower valves | Rotate-only single lever | Threaded bonnet nut |

## What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Which rough-in valves fit Pfister 910-0300?

Pfister 910-0300 fits Pfister Bedford, Pasadena, Kenzo, Contempra two-handle faucets. Cross-check Brass housing with ceramic discs and lower EPDM seat washer before ordering.

### How do I identify Pfister 910-0300 without removing it first?

Test handle motion (Quarter-turn 90-degree rotation (reversible hot/cold stop)) and inspect under the sleeve for Threaded brass stem nut.

### Are the specifications on Pfister 910-0300 sourced from public records?

Numbers cited in Pfister 910-0300 originate from U.S. federal agencies, state licensing portals, or manufacturer specifications without invented scores. Confirmed fitment applies across Pfister Bedford, Pasadena, Kenzo, Contempra two-handle faucets.

### Which conditions override general reference data for Pfister 910-0300?

Always confirm city-level code amendments and call 911 outdoors for gas odors before performing work related to Pfister 910-0300. Shut off house or local isolation valves and release pressure before removing retaining clips or bonnet nuts.

### What national code ceilings govern Pfister 910-0300?

Homeowners must balance municipal IPC/UPC amendments (80 psi PRV limits, backflow testing) alongside EPA water caps and 2029 DOE heater rules.

### Are DOE HEAR rebates still available after 25C expired?

Because P.L. 119-21 terminated 25C on Dec 31, 2025, 2026 incentives come through state DOE HEAR portals (<=150% AMI) and electric or water district rebates.

### When should a homeowner escalate Pfister 910-0300 to a state-licensed plumber?

Escalate whenever tasks involve fuel-gas piping, Category IV exhaust venting, 240V electrical circuits, main shutoff valves, or permitted sewer excavations.

### Does TapAndPipe accept paid placements inside Pfister 910-0300?

No. All specifications, state benchmarks, and contractor lists derive strictly from official public records and OEM manuals with zero paid ranking boosts.

## Which Related Cartridges and Wizards Should You Check?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Launch Photo-Less Cartridge Identifier Wizard→](https://gcsradheat.com/tools/cartridge-pipe-identifier/)
- [Open Moen Shower Cartridge Technical Comparison→](https://gcsradheat.com/compare/moen-1222-vs-1225-vs-1255/)
- [Open Delta MultiChoice Cartridge Comparison→](https://gcsradheat.com/compare/delta-rp46074-vs-rp19804/)
- [Compare Grohe 46048000→](https://gcsradheat.com/parts/grohe/grohe-46048000-silkmove/)
- [Compare Grohe 47439000 / 47175000→](https://gcsradheat.com/parts/grohe/grohe-34331-turbostat/)

## Sources

1. [Pfister, Grohe & American Standard Ceramic Disc Cartridge & Flush Valve Specifications](https://www.pfisterfaucets.com/parts-support) — Pfister / Grohe / LIXIL American Standard, 2026 OEM Replacement Parts Matrix (retrieved 2026-11-25)
2. [ASTM B88 Copper Water Tube & ASME B1.20.1 Pipe Threads](https://www.astm.org/b0088-22.html) — ASTM International & ASME, ASTM B88 / F876 / ASME B1.20.1 (retrieved 2026-11-23)
3. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
4. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)

Safe removal reminder

Always shut off both hot and cold isolation stops and relieve water pressure before removing retainer clips or bonnet nuts.