# SharkBite Max vs. 1st-Gen Push-to-Connect Insertion Depth & Liner Spec

Designed for Copper (ASTM B88 K/L/M), PEX-A/B/C (ASTM F876), CPVC (ASTM D2846), PE-RT transition couplings, SharkBite UR008A vs U008LF uses Push-to-connect tool-free join (no solder/crimp); requires full deburring action with 316 stainless steel teeth ring + EPDM O-ring. NOT rated for galvanized steel, Polybutylene (requires PB transition fitting U4008LF), or schedule 40 PVC supply.

- **OEM Part Number**: UR008A vs U008LF

- **Operating / Join Action**: Push-to-connect tool-free join

- **Retainer / Seal Style**: 316 stainless steel teeth ring + EPDM O-ring

- **Compatible Series**: 3 Platforms

Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip

How to tell this part apart

Mechanical checks for SharkBite UR008A vs U008LF: motion — Push-to-connect tool-free join (no solder/crimp); requires full deburring; retainer — 316 stainless steel teeth ring + EPDM O-ring. Stem cue: Insertion depth: 1/2 in. = 1.00 in. (Max) vs 0.95 in. (Gen1); 3/4 in. = 1.25 in. (Max) vs 1.13 in. (Gen1).

NOT rated for galvanized steel, Polybutylene (requires PB transition fitting U4008LF), or schedule 40 PVC supply.

## How Do You Identify the SharkBite UR008A vs U008LF Retainer?

Verify handle motion (Push-to-connect tool-free join) and retaining hardware (316 stainless steel teeth ring + EPDM O-ring) under the trim plate before pulling the cartridge or shutting off supply stops.

Mechanical retainer anatomy: verify retainer style and handle action (rotate-only vs. pull-turn) before shutting water off or ordering OEM cartridges.

## What Valves Fit SharkBite UR008A vs U008LF?

Review complete OEM fitment specifications, body construction, non-interchangeable warnings, and federal WaterSense flow ceilings (45,604 certified fixtures) for UR008A vs U008LF below.

Verified OEM technical attributes for SharkBite UR008A vs U008LF

| Attribute | Verified Specification |
|---|---|
| Primary Application | Copper (ASTM B88 K/L/M), PEX-A/B/C (ASTM F876), CPVC (ASTM D2846), PE-RT transition couplings |
| Handle Action | Push-to-connect tool-free join (no solder/crimp); requires full deburring |
| Retainer Mechanism | 316 stainless steel teeth ring + EPDM O-ring |
| Body & Seal Construction | Lead-free DZR forged brass; SharkBite Max eliminates PEX tube stiffener on 1/2-3/4 in. via reinforced collar |
| Stem / Fitment Note | Insertion depth: 1/2 in. = 1.00 in. (Max) vs 0.95 in. (Gen1); 3/4 in. = 1.25 in. (Max) vs 1.13 in. (Gen1) |
| Compatible Valve Platforms | Copper 1/2-1 in. / PEX CTS 1/2-1 in. / CPVC CTS 1/2-1 in. |
| Non-Interchangeable Warning | NOT rated for galvanized steel, Polybutylene (requires PB transition fitting U4008LF), or schedule 40 PVC supply. |
| Federal Fixture Flow Rules | Faucets ≤2.2 gpm @ 60 psi under 10 CFR 430.32(o); WaterSense ≤1.5 gpm across 45,604 certified fixtures |

## How Does UR008A vs U008LF Compare to Peer OEM Parts?

Cross-check 6 adjacent residential OEM shower cartridges, push-to-connect couplings, and RPZ backflow repair assemblies to avoid incompatible part orders.

Cross-reference matrix of indexed residential OEM cartridges, connectors, and backflow kits

| Brand & Part # | Application | Handle / Join Action | Retainer Mechanism |
|---|---|---|---|
| [Moen 1222](https://gcsradheat.com/parts/moen/moen-1222-posi-temp/) | Posi-Temp tub and shower pressure-balancing valves | Rotate-only | Vertical wire/U-clip inserted through top of brass valve body |
| [Moen 1225](https://gcsradheat.com/parts/moen/moen-1225-magnum/) | Single-handle kitchen, bath, and Chateau shower faucets | Pull out for volume, turn left/right for temperature | Top brass/wire retainer clip behind escutcheon sleeve |
| [Moen 1255](https://gcsradheat.com/parts/moen/moen-1255-duralast/) | Post-2009 single-handle kitchen and bath sink faucets | Lift/tilt lever forward-back + swivel left-right | Threaded plastic locking nut |
| [Delta RP46074](https://gcsradheat.com/parts/delta/delta-rp46074-multichoice/) | Post-2007 Delta 13/14 Series MultiChoice shower valves | Rotate-only single handle | Large threaded chrome/brass bonnet nut over valve body |
| [Delta RP19804](https://gcsradheat.com/parts/delta/delta-rp19804-legacy/) | Pre-2007 Monitor 1300 and 1400 tub/shower valves | Rotate-only single lever | Threaded bonnet nut |
| [Kohler GP800820 / GP500520](https://gcsradheat.com/parts/kohler/kohler-gp800820-rite-temp/) | Kohler Rite-Temp K-304 and K-8304 shower valves | Rotate-only single handle | 4-bolt stainless plate |

## What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Which rough-in valves fit SharkBite UR008A vs U008LF?

SharkBite UR008A vs U008LF fits Copper 1/2-1 in., PEX CTS 1/2-1 in., CPVC CTS 1/2-1 in.. Cross-check Lead-free DZR forged brass; SharkBite Max eliminates PEX tube stiffener on 1/2-3/4 in. via reinforced collar before ordering.

### How do I identify SharkBite UR008A vs U008LF without removing it first?

Test handle motion (Push-to-connect tool-free join (no solder/crimp); requires full deburring) and inspect under the sleeve for 316 stainless steel teeth ring + EPDM O-ring.

### Which official agencies and manuals back SharkBite UR008A vs U008LF?

All figures for SharkBite UR008A vs U008LF trace directly to public federal datasets, model IPC/UPC codes, and published manufacturer sheets. Confirmed fitment applies across Copper 1/2-1 in., PEX CTS 1/2-1 in., CPVC CTS 1/2-1 in..

### When does SharkBite UR008A vs U008LF require an on-site licensed inspection?

General benchmarks never replace municipal building rules or licensed diagnostics on pressurized fuel gas, sealed burners, or electrical panels. Shut off house or local isolation valves and release pressure before removing retaining clips or bonnet nuts.

### Which 2026–2029 federal and IPC/UPC limits affect SharkBite UR008A vs U008LF?

Residential compliance spans IPC/UPC trap-arm and pressure caps (<=80 psi), NFPA 54 / IFGC fuel gas capacities, EPA 10 ppb LCRI lead rules, and 2029 DOE UEF standards.

### What replaced the $2,000 federal 25C credit in 2026?

IRC Section 25C expired December 31, 2025 under OBBBA; state-administered DOE HEAR grants (up to $1,750 income-qualified) and municipal utility rebates remain.

### When should a homeowner escalate SharkBite UR008A vs U008LF to a state-licensed plumber?

Escalate whenever tasks involve fuel-gas piping, Category IV exhaust venting, 240V electrical circuits, main shutoff valves, or permitted sewer excavations.

### Does TapAndPipe accept paid placements inside SharkBite UR008A vs U008LF?

No. All specifications, state benchmarks, and contractor lists derive strictly from official public records and OEM manuals with zero paid ranking boosts.

## Which Related Cartridges and Wizards Should You Check?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Launch Photo-Less Cartridge Identifier Wizard→](https://gcsradheat.com/tools/cartridge-pipe-identifier/)
- [Open Moen Shower Cartridge Technical Comparison→](https://gcsradheat.com/compare/moen-1222-vs-1225-vs-1255/)
- [Open Delta MultiChoice Cartridge Comparison→](https://gcsradheat.com/compare/delta-rp46074-vs-rp19804/)
- [Compare Zurn Wilkins 975XL / RK34-975XL→](https://gcsradheat.com/parts/zurn/zurn-975xl-backflow/)
- [Compare Moen 1200 / 1200B→](https://gcsradheat.com/parts/moen/moen-1200-brass/)

## Sources

1. [Zurn Backflow, Uponor PEX-a Expansion & SharkBite Push-to-Connect Insertion Specs](https://www.sharkbite.com/us/en/resources/installation-instructions) — Zurn Elkay / Uponor / Reliance Worldwide Corp (SharkBite), 2026 OEM Installation Specifications (retrieved 2026-11-23)
2. [ASTM B88 Copper Water Tube & ASME B1.20.1 Pipe Threads](https://www.astm.org/b0088-22.html) — ASTM International & ASME, ASTM B88 / F876 / ASME B1.20.1 (retrieved 2026-11-23)
3. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
4. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)

Safe removal reminder

Always shut off both hot and cold isolation stops and relieve water pressure before removing retainer clips or bonnet nuts.
[Launch Cartridge Wizard](https://gcsradheat.com/tools/cartridge-pipe-identifier/)