title: "Zurn Wilkins 350XL / RK34-350 Cartridge Specs & Fitment"
url: https://gcsradheat.com/parts/zurn/zurn-350xl-double-check/
description: "Verified fitment for Zurn Wilkins 350XL Double Check Valve Backflow Assembly (DCVA) (350XL / RK34-350) covers Zurn 350XL / 350AST 3/4 in. and 1 in. assemblies."
---

OEM part specification · Zurn Wilkins

# Zurn Wilkins 350XL Double Check Valve Backflow Assembly (DCVA)

Verified fitment for Zurn Wilkins 350XL Double Check Valve Backflow Assembly (DCVA) (350XL / RK34-350) covers Zurn 350XL / 350AST 3/4 in. and 1 in. assemblies; verify Pop-out modular cartridge allows rapid winterization & annual gauge test before ordering. Verify exact stem geometry (Pop-out modular cartridge allows rapid winterization & annual gauge test) and shut off hot and cold isolation stops before removing retaining clips.

- **OEM Part Number**: 350XL / RK34-350

- **Operating / Join Action**: Two spring-loaded check valves inside removable composite pressure vessel

- **Retainer / Seal Style**: Flush-mount threaded top check-module cover

- **Compatible Series**: 1 Platform

Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip

How to tell this part apart

Mechanical checks for Zurn Wilkins 350XL / RK34-350: motion — Two spring-loaded check valves inside removable composite pressure vessel; retainer — Flush-mount threaded top check-module cover (tool-free cartridge pull). Stem cue: Pop-out modular cartridge allows rapid winterization & annual gauge test.

NOT approved for high-hazard chemical/fertilizer injection systems (requires 975XL RPZ).

## How Do You Identify the Zurn Wilkins 350XL / RK34-350 Retainer?

Verify handle motion (Two spring-loaded check valves inside removable composite pressure vessel) and retaining hardware (Flush-mount threaded top check-module cover) under the trim plate before pulling the cartridge or shutting off supply stops.

Mechanical retainer anatomy: verify retainer style and handle action (rotate-only vs. pull-turn) before shutting water off or ordering OEM cartridges.

## What Valves Fit Zurn Wilkins 350XL / RK34-350?

Review complete OEM fitment specifications, body construction, non-interchangeable warnings, and federal WaterSense flow ceilings (45,604 certified fixtures) for 350XL / RK34-350 below.

Verified OEM technical attributes for Zurn Wilkins 350XL / RK34-350

| Attribute | Verified Specification |
|---|---|
| Primary Application | Low-to-medium hazard potable water backflow protection (residential lawn irrigation & fire lines) |
| Handle Action | Two spring-loaded check valves inside removable composite pressure vessel |
| Retainer Mechanism | Flush-mount threaded top check-module cover (tool-free cartridge pull) |
| Body & Seal Construction | Lead-free bronze shutoff valves + replaceable polymer check vessel |
| Stem / Fitment Note | Pop-out modular cartridge allows rapid winterization & annual gauge test |
| Compatible Valve Platforms | Zurn 350XL / 350AST 3/4 in. and 1 in. assemblies |
| Non-Interchangeable Warning | NOT approved for high-hazard chemical/fertilizer injection systems (requires 975XL RPZ). |
| Federal Fixture Flow Rules | Faucets ≤2.2 gpm @ 60 psi under 10 CFR 430.32(o); WaterSense ≤1.5 gpm across 45,604 certified fixtures |

## How Does 350XL / RK34-350 Compare to Peer OEM Parts?

Cross-check 6 adjacent residential OEM shower cartridges, push-to-connect couplings, and RPZ backflow repair assemblies to avoid incompatible part orders.

Cross-reference matrix of indexed residential OEM cartridges, connectors, and backflow kits

| Brand & Part # | Application | Handle / Join Action | Retainer Mechanism |
|---|---|---|---|
| [Zurn Wilkins 975XL / RK34-975XL](https://gcsradheat.com/parts/zurn/zurn-975xl-backflow/) | RPZ potable backflow protection (irrigation & boilers) | Two independent spring-loaded check valves + differential relief valve | Threaded brass check covers and relief seat |
| [Moen 1222](https://gcsradheat.com/parts/moen/moen-1222-posi-temp/) | Posi-Temp tub and shower pressure-balancing valves | Rotate-only | Vertical wire/U-clip inserted through top of brass valve body |
| [Moen 1225](https://gcsradheat.com/parts/moen/moen-1225-magnum/) | Single-handle kitchen, bath, and Chateau shower faucets | Pull out for volume, turn left/right for temperature | Top brass/wire retainer clip behind escutcheon sleeve |
| [Moen 1255](https://gcsradheat.com/parts/moen/moen-1255-duralast/) | Post-2009 single-handle kitchen and bath sink faucets | Lift/tilt lever forward-back + swivel left-right | Threaded plastic locking nut |
| [Delta RP46074](https://gcsradheat.com/parts/delta/delta-rp46074-multichoice/) | Post-2007 Delta 13/14 Series MultiChoice shower valves | Rotate-only single handle | Large threaded chrome/brass bonnet nut over valve body |
| [Delta RP19804](https://gcsradheat.com/parts/delta/delta-rp19804-legacy/) | Pre-2007 Monitor 1300 and 1400 tub/shower valves | Rotate-only single lever | Threaded bonnet nut |

## What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Which rough-in valves fit Zurn Wilkins 350XL / RK34-350?

Zurn Wilkins 350XL / RK34-350 fits Zurn 350XL / 350AST 3/4 in. and 1 in. assemblies. Cross-check Lead-free bronze shutoff valves + replaceable polymer check vessel before ordering.

### How do I identify Zurn Wilkins 350XL / RK34-350 without removing it first?

Test handle motion (Two spring-loaded check valves inside removable composite pressure vessel) and inspect under the sleeve for Flush-mount threaded top check-module cover (tool-free cartridge pull).

### Where do the engineering metrics for Zurn Wilkins 350XL / RK34-350 originate?

Data provenance for Zurn Wilkins 350XL / RK34-350 links straight to verified agency releases and OEM installation bulletins. Confirmed fitment applies across Zurn 350XL / 350AST 3/4 in. and 1 in. assemblies.

### When should homeowners stop and call 911 or a pro on Zurn Wilkins 350XL / RK34-350?

Online tables clarify baseline engineering limits, not site-specific hazards like live gas odors or corroded service mains. Shut off house or local isolation valves and release pressure before removing retaining clips or bonnet nuts.

### Which federal regulatory baselines intersect with Zurn Wilkins 350XL / RK34-350?

Check local Authority Having Jurisdiction amendments to IPC/UPC codes alongside federal EPA drinking water and 10 CFR 430 efficiency mandates.

### Which incentives remain open in 2026 for plumbing equipment?

Verify active state DOE HEAR allocations (up to $1,750 for heat pump water heaters) and local utility rebates following the Dec 31, 2025 25C expiration.

### When should a homeowner escalate Zurn Wilkins 350XL / RK34-350 to a state-licensed plumber?

Escalate whenever tasks involve fuel-gas piping, Category IV exhaust venting, 240V electrical circuits, main shutoff valves, or permitted sewer excavations.

### Does TapAndPipe accept paid placements inside Zurn Wilkins 350XL / RK34-350?

No. All specifications, state benchmarks, and contractor lists derive strictly from official public records and OEM manuals with zero paid ranking boosts.

## Which Related Cartridges and Wizards Should You Check?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Launch Photo-Less Cartridge Identifier Wizard→](https://gcsradheat.com/tools/cartridge-pipe-identifier/)
- [Open Moen Shower Cartridge Technical Comparison→](https://gcsradheat.com/compare/moen-1222-vs-1225-vs-1255/)
- [Open Delta MultiChoice Cartridge Comparison→](https://gcsradheat.com/compare/delta-rp46074-vs-rp19804/)
- [Compare Moen 1222→](https://gcsradheat.com/parts/moen/moen-1222-posi-temp/)
- [Compare Moen 1225→](https://gcsradheat.com/parts/moen/moen-1225-magnum/)

## Sources

1. [Zurn Backflow, Uponor PEX-a Expansion & SharkBite Push-to-Connect Insertion Specs](https://www.sharkbite.com/us/en/resources/installation-instructions) — Zurn Elkay / Uponor / Reliance Worldwide Corp (SharkBite), 2026 OEM Installation Specifications (retrieved 2026-11-23)
2. [ASTM B88 Copper Water Tube & ASME B1.20.1 Pipe Threads](https://www.astm.org/b0088-22.html) — ASTM International & ASME, ASTM B88 / F876 / ASME B1.20.1 (retrieved 2026-11-23)
3. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
4. [EPA WaterSense Labeled Plumbing Products Registry](https://lookforwatersense.epa.gov/products/) — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)

Safe removal reminder

Always shut off both hot and cold isolation stops and relieve water pressure before removing retainer clips or bonnet nuts.
[Launch Cartridge Wizard](https://gcsradheat.com/tools/cartridge-pipe-identifier/)