title: "A. O. Smith CAHP-50 2** (3.68 UEF, 46 gal)"
url: https://gcsradheat.com/water-heaters/a-o-smith/cahp-50-2/
description: "In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith CAHP-50 2** (Electric) achieves a certified 3.68 UEF rating across its 46-gallon nominal tank, 65."
---

ENERGY STAR water heater model · PD 4689619

# A. O. Smith CAHP-50 2** Water Heater Specifications (3.68 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith CAHP-50 2** (Electric) achieves a certified 3.68 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating (rank #389 of 706, PD 4689619) and verifies as Pass: +1.38 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 883 kWh/yr equates to roughly $160/yr ($1,604 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPA10250H045DV 2** (3.68 UEF).

- **Uniform Energy Factor**: 3.68 UEF

- **Cohort UEF Rank**: #389 of 706

- **First Hour Rating**: 65 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.38 / +60.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith CAHP-50 2** relative to the cohort median.

Efficiency comparison & rule summary

A. O. Smith CAHP-50 2** records 3.68 UEF efficiency, putting it #389 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith CAHP-50 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.38 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 883 kWh/yr for A. O. Smith CAHP-50 2** runs ~$160/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith CAHP-50 2**: 10-year operating spend spans $1,292 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,166 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith CAHP-50 2** (3.68 UEF) are American HPA10250H045DV 2** (3.68 UEF, at parity) and Lochinvar CHPA-50 2** (3.68 UEF, at parity).

## How Do A. O. Smith CAHP-50 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

A. O. Smith CAHP-50 2** places #389 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 4689619 |
| Model Number | CAHP-50 2** | Draw pattern: Medium-Usage | CAHP-50 2** |
| Uniform Energy Factor (UEF) | 3.68 | -0.02 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 883 kWh/yr | -189 kWh/yr vs. 1,072 kWh/yr median | Est. $160/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 416% | -13.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-08-13 | Certified 2026-08-13 | Markets: United States |

## What Does CAHP-50 2** Cost to Operate Across State Electricity Rates?

At 883 kWh/yr, A. O. Smith CAHP-50 2** runs roughly $160/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $160/yr | $1,604 | $4,811 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $417/yr | $4,166 | $12,498 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $263/yr | $2,627 | $7,881 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $140/yr | $1,405 | $4,215 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $129/yr | $1,292 | $3,875 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (883 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match CAHP-50 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith CAHP-50 2** by storage capacity and 3.68 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American HPA10250H045DV 2**](https://gcsradheat.com/water-heaters/american/hpa10250h045dv-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [Lochinvar CHPA-50 2**](https://gcsradheat.com/water-heaters/lochinvar/chpa-50-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [RELIANCE WATER HEATERS 10-50-DHPTA 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-50-dhpta-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [State CSHP-50 2**](https://gcsradheat.com/water-heaters/state/cshp-50-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [Lochinvar HPPA050KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hppa050kd-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |

## When Should Homeowners Skip A. O. Smith CAHP-50 2** (Hybrid/Electric Heat Pump)?

Check A. O. Smith CAHP-50 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.38 / +60.0% status—against typical residential installations.

### Key Limitations & Exclusions

- A. O. Smith CAHP-50 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith CAHP-50 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing A. O. Smith CAHP-50 2 Strong Fit — 3.68 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare American HPA10250H045DV 2** footprint.

## What Are the Key Questions About A. O. Smith CAHP-50 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will A. O. Smith CAHP-50 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.68 UEF, A. O. Smith CAHP-50 2** shows Pass: +1.38 / +60.0% relative to May 6, 2029 federal DOE limits while placing #389 of 706 among 706 Hybrid/Electric Heat Pump peers like American HPA10250H045DV 2**.

### Will A. O. Smith CAHP-50 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 63 in. tall by 15 in. diameter, A. O. Smith CAHP-50 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support A. O. Smith CAHP-50 2** during replacement?

Electrical specs for A. O. Smith CAHP-50 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for A. O. Smith CAHP-50 2**?

At 18.16 cents/kWh national residential pricing, A. O. Smith CAHP-50 2**'s 883 kWh/yr draw equals roughly $160 annually or $1,600 across a 10-year horizon (ranging from $129/yr in Washington hydro tiers up to $417/yr in Hawaii).

### When is A. O. Smith CAHP-50 2** a poor fit for a residential replacement?

Avoid placing A. O. Smith CAHP-50 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does A. O. Smith CAHP-50 2** deliver?

With 65 gal FHR (-7 gal vs. 72 gal median), A. O. Smith CAHP-50 2** fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on A. O. Smith CAHP-50 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Does A. O. Smith CAHP-50 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith CAHP-50 2**. Closest peer in Hybrid/Electric Heat Pump is American HPA10250H045DV 2** (3.68 UEF).

## Which Sizing and Compliance Guides Pair with CAHP-50 2**?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American HPA10250H045DV 2** (3.68 UEF)→](https://gcsradheat.com/water-heaters/american/hpa10250h045dv-2/)
- [Compare Lochinvar CHPA-50 2** (3.68 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/chpa-50-2/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)