title: "A. O. Smith FPTU-80 1** (3.45 UEF, 82 gal)"
url: https://gcsradheat.com/water-heaters/a-o-smith/fptu-80-1/
description: "Certified at 3.45 UEF across its 82-gallon nominal tank, 84 gal First Hour Rating, A. O. Smith FPTU-80 1** (Hybrid/Electric Heat Pump, Electric) places #563 of."
---

ENERGY STAR water heater model · PD 2408886

# A. O. Smith FPTU-80 1** Water Heater Specifications (3.45 UEF)

Certified at 3.45 UEF across its 82-gallon nominal tank, 84 gal First Hour Rating, A. O. Smith FPTU-80 1** (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 2408886). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,396 kWh/yr equates to roughly $254/yr ($2,535 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE6280H045DV 1** (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 84 gal

- **Storage Volume**: 82 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.95 / +38.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith FPTU-80 1** relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.45 UEF, A. O. Smith FPTU-80 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).

A. O. Smith FPTU-80 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,396 kWh/yr for A. O. Smith FPTU-80 1** runs ~$254/yr vs. ~$951/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith FPTU-80 1**: 10-year operating spend spans $2,042 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to A. O. Smith FPTU-80 1** include American HPHE6280H045DV 1** (3.45 UEF, at parity) alongside RELIANCE WATER HEATERS 6-80-DHPHT 1** (3.45 UEF, at parity).

## How Do A. O. Smith FPTU-80 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

A. O. Smith FPTU-80 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 2408886 |
| Model Number | FPTU-80 1** | Draw pattern: High-Usage | FPTU-80 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 84 gal | +12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,396 kWh/yr | +324 kWh/yr vs. 1,072 kWh/yr median | Est. $254/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 233% | -196.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |

## What Does FPTU-80 1** Cost to Operate Across State Electricity Rates?

At 1,396 kWh/yr, A. O. Smith FPTU-80 1** runs roughly $254/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $254/yr | $2,535 | $6,972 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $659/yr | $6,586 | $18,112 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $415/yr | $4,153 | $11,421 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $222/yr | $2,221 | $6,108 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $204/yr | $2,042 | $5,616 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,396 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match FPTU-80 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith FPTU-80 1** by storage capacity and 3.45 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American HPHE6280H045DV 1**](https://gcsradheat.com/water-heaters/american/hphe6280h045dv-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [RELIANCE WATER HEATERS 6-80-DHPHT 1**](https://gcsradheat.com/water-heaters/reliance-water-heaters/6-80-dhpht-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [State HP6-80-DHPT 1**](https://gcsradheat.com/water-heaters/state/hp6-80-dhpt-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [U.S. Craftmaster HPHE2F80HD045VU 1**](https://gcsradheat.com/water-heaters/u-s-craftmaster/hphe2f80hd045vu-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [American HPHE10280H045DVCTA-1**](https://gcsradheat.com/water-heaters/american/hphe10280h045dvcta-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |

## What Installation Caveats Apply Before Buying A. O. Smith FPTU-80 1**?

Even high-UEF units like A. O. Smith FPTU-80 1** (3.45 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- A. O. Smith FPTU-80 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith FPTU-80 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing A. O. Smith FPTU-80 1 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare American HPHE6280H045DV 1** footprint.

## What Are the Key Questions About A. O. Smith FPTU-80 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is A. O. Smith FPTU-80 1** eligible for continued manufacture past May 6, 2029?

At 3.45 UEF, A. O. Smith FPTU-80 1** achieves Pass: +0.95 / +38.0% for the 2029 DOE standard and stands #563 of 706 against American HPHE6280H045DV 1** and RELIANCE WATER HEATERS 6-80-DHPHT 1**.

### How tall and wide is A. O. Smith FPTU-80 1**, and what service clearance is needed?

Physical dimensions for A. O. Smith FPTU-80 1** are 69 in. height and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)); verify stair turns and drain pan width before delivery.

### Will A. O. Smith FPTU-80 1** require upgrading household electrical panels or gas piping?

A. O. Smith FPTU-80 1** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is A. O. Smith FPTU-80 1** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $254/yr ($2,540 over 10 years) to power A. O. Smith FPTU-80 1** at 1,396 kWh/yr under the 18.16 cents/kWh US average (ranging from $204/yr in Washington hydro tiers up to $659/yr in Hawaii).

### Which installation bottlenecks limit A. O. Smith FPTU-80 1**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith FPTU-80 1** drops into resistance mode more often.

### How does A. O. Smith FPTU-80 1** handle simultaneous showers and laundry?

Delivering 84 gal in the first hour (+12 gal vs. 72 gal median), A. O. Smith FPTU-80 1** combines 82 gal tank storage with rapid burner/element recovery.

### How long is the warranty on A. O. Smith FPTU-80 1** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying A. O. Smith FPTU-80 1**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPHE6280H045DV 1** (3.45 UEF).

## Which Sizing and Compliance Guides Pair with FPTU-80 1**?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American HPHE6280H045DV 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/american/hphe6280h045dv-1/)
- [Compare RELIANCE WATER HEATERS 6-80-DHPHT 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/reliance-water-heaters/6-80-dhpht-1/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)