# A. O. Smith GPCC-40L 1** Water Heater Specifications (0.9 UEF)

Certified at 0.9 UEF across its 38-gallon nominal tank, 86 gal First Hour Rating, A. O. Smith GPCC-40L 1** (Gas Storage, Natural Gas, Propane) places #1 of 71 out of 71 ENERGY STAR models (PD 2408766). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.32 / +55.2%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is American PCG62-40S50L 1** (0.9 UEF).

- **Uniform Energy Factor**: 0.9 UEF

- **Cohort UEF Rank**: #1 of 71

- **First Hour Rating**: 86 gal

- **Storage Volume**: 38 gal

- **Fuel / Type**: Natural Gas, Propane / Gas Storage

- **DOE 2029 Rule Status**: Pass: +0.32 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows A. O. Smith GPCC-40L 1** relative to the cohort median.

Efficiency comparison & rule summary

Tested at 0.9 UEF, A. O. Smith GPCC-40L 1** places #1 of 71 across 71 certified Gas Storage configurations (At 0.90 UEF median).

A. o. smith gpcc-40l 1** stores 38 gal nominal; 86 gal first hour rating (-9 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

Closest alternatives to A. O. Smith GPCC-40L 1** include American PCG62-40S50L 1** (0.9 UEF, at parity) alongside Envirosense Enercare ENV-40N-ENER 1** (0.9 UEF, at parity).

## What Physical and Thermal Ratings Define A. O. Smith GPCC-40L 1**?

Positioning at #1 of 71 out of 71 Gas Storage peers, A. O. Smith GPCC-40L 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 2408766 |
| Model Number | GPCC-40L 1** | Draw pattern: High-Usage | GPCC-40L 1** |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | -9 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 91% | -3.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 44.7" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 2 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any A. O. Smith Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## What Are 5 Direct Alternatives to A. O. Smith GPCC-40L 1**?

Homeowners cross-shopping A. O. Smith GPCC-40L 1** frequently review these five Gas Storage models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American PCG62-40S50L 1**](https://gcsradheat.com/water-heaters/american/pcg62-40s50l-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Envirosense Enercare ENV-40N-ENER 1**](https://gcsradheat.com/water-heaters/envirosense-enercare/env-40n-ener-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Envirosense Reliance Home Comfort ENV-40N-RHC 1**](https://gcsradheat.com/water-heaters/envirosense-reliance-home-comfort/env-40n-rhc-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Envirosense ENV-40N 1**](https://gcsradheat.com/water-heaters/envirosense/env-40n-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [American PCG82-40S50L 1**](https://gcsradheat.com/water-heaters/american/pcg82-40s50l-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |

## Which Home Setups Are NOT a Fit for A. O. Smith GPCC-40L 1**?

Comparing A. O. Smith GPCC-40L 1** against American PCG62-40S50L 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- A. O. Smith GPCC-40L 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect A. O. Smith GPCC-40L 1**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 86 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for A. O. Smith GPCC-40L 1 Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like American PCG62-40S50L 1**.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Sizing, Efficiency & Recall Answers for A. O. Smith GPCC-40L 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does A. O. Smith GPCC-40L 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith GPCC-40L 1** logs 0.9 UEF (Pass: +0.32 / +55.2%) within the 71-unit Gas Storage group.

### What physical clearance dimensions apply when installing A. O. Smith GPCC-40L 1**?

With a 44.7 in. height and 22 in. diameter, A. O. Smith GPCC-40L 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits A. O. Smith GPCC-40L 1**?

A. O. Smith GPCC-40L 1** utilizes Natural Gas, Propane combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

### How do state electricity prices change annual costs for A. O. Smith GPCC-40L 1**?

A. O. Smith GPCC-40L 1** operates on Natural Gas, Propane (0.9 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

### What homeowner setups should avoid choosing A. O. Smith GPCC-40L 1**?

Homes with >10.5 GPG Very Hard well water without regular 6-month sediment draining will shorten the tank life of A. O. Smith GPCC-40L 1** (Pass: +0.32 / +55.2%).

### Is A. O. Smith GPCC-40L 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies A. O. Smith GPCC-40L 1** at 86 gal First Hour Rating (-9 gal vs. 95 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does A. O. Smith have active CPSC SaferProducts notices affecting GPCC-40L 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches A. O. Smith GPCC-40L 1** (0.9 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith GPCC-40L 1**. Closest peer in Gas Storage is American PCG62-40S50L 1** (0.9 UEF).

## Related Rebate, Gas-Line & Serial Tools for GPCC-40L 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American PCG62-40S50L 1** (0.9 UEF)→](https://gcsradheat.com/water-heaters/american/pcg62-40s50l-1/)
- [Compare Envirosense Enercare ENV-40N-ENER 1** (0.9 UEF)→](https://gcsradheat.com/water-heaters/envirosense-enercare/env-40n-ener-1/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)