title: "A. O. Smith GT15-340-NI 1** (0.95 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/a-o-smith/gt15-340-ni-1/
description: "In the 464-unit Gas Tankless class, A. O. Smith GT15-340-NI 1** (Natural Gas) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 2408799) and verifies."
---

ENERGY STAR water heater model · PD 2408799

# A. O. Smith GT15-340-NI 1** Water Heater Specifications (0.95 UEF)

In the 464-unit Gas Tankless class, A. O. Smith GT15-340-NI 1** (Natural Gas) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 2408799) and verifies as Pass: +0.04 / +4.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is American GT-240-NEH 1** (0.95 UEF).

- **Uniform Energy Factor**: 0.95 UEF

- **Cohort UEF Rank**: #159 of 464

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Natural Gas / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.04 / +4.4%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows A. O. Smith GT15-340-NI 1** relative to the cohort median.

Efficiency comparison & rule summary

A. O. Smith GT15-340-NI 1** records 0.95 UEF efficiency, putting it #159 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: A. O. Smith GT15-340-NI 1** sits +0.04 UEF (+4.4%) above 0.91 UEF.

Competing options beside A. O. Smith GT15-340-NI 1** (0.95 UEF) are American GT-240-NEH 1** (0.95 UEF, at parity) and Bosch T9800 SE 160 (0.95 UEF, at parity).

## How Do A. O. Smith GT15-340-NI 1** Specs Compare to Gas Tankless Medians?

A. O. Smith GT15-340-NI 1** places #159 of 464 across 464 certified Gas Tankless configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 2408799 |
| Model Number | GT15-340-NI 1** | Draw pattern: High-Usage | GT15-340-NI 1** |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match GT15-340-NI 1** Most Closely?

These 5 competing Gas Tankless units sit nearest to A. O. Smith GT15-340-NI 1** by storage capacity and 0.95 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American GT-240-NEH 1**](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bosch T9800 SE 160](https://gcsradheat.com/water-heaters/bosch/t9800-se-160/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bradford White RTG-K-160N1](https://gcsradheat.com/water-heaters/bradford-white/rtg-k-160n1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Elios EROD150N0000](https://gcsradheat.com/water-heaters/elios/erod150n0000/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [American GT-240-PEH 1*1](https://gcsradheat.com/water-heaters/american/gt-240-peh-1-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |

## What Are the Limitations of A. O. Smith GT15-340-NI 1** and Who Should Not Install It?

Before ordering A. O. Smith GT15-340-NI 1** (Gas Tankless, 0.95 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Converting a 40K tank to A. O. Smith GT15-340-NI 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect A. O. Smith GT15-340-NI 1**'s heat exchanger.
- Condensing A. O. Smith GT15-340-NI 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — A. O. Smith GT15-340-NI 1** delivers continuous 0.95 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## What Are the Key Questions About A. O. Smith GT15-340-NI 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does A. O. Smith GT15-340-NI 1** pass the May 6, 2029 federal DOE efficiency rule?

A. O. Smith GT15-340-NI 1** carries a verified 0.95 UEF rating (Pass: +0.04 / +4.4%), ranking #159 of 464 across 464 ENERGY STAR Gas Tankless models under 10 CFR 430.32.

### What doorway width and ceiling height does A. O. Smith GT15-340-NI 1** need?

A. O. Smith GT15-340-NI 1** mounts as a gas tankless without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

### What gas pipe size or electrical breaker does A. O. Smith GT15-340-NI 1** require?

A. O. Smith GT15-340-NI 1** runs on Natural Gas (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does A. O. Smith GT15-340-NI 1** cost per year to run?

ENERGY STAR rates A. O. Smith GT15-340-NI 1** as a Natural Gas heater (0.95 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Tankless draw.

### Who should NOT install A. O. Smith GT15-340-NI 1**, and what are its limits?

A. O. Smith GT15-340-NI 1** (0.95 UEF) is rarely a drop-in swap over a 40K tank if existing 1/2 in. gas pipe cannot supply 199,000 BTU/h or hardness exceeds 7.0 GPG without descaling.

### How many bathrooms or people can A. O. Smith GT15-340-NI 1** serve at peak demand?

A. O. Smith GT15-340-NI 1** provides continuous Gas Tankless delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

### Are there CPSC safety recalls or serial checks for A. O. Smith GT15-340-NI 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to A. O. Smith GT15-340-NI 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Tankless is American GT-240-NEH 1** (0.95 UEF).

## Which Sizing and Compliance Guides Pair with GT15-340-NI 1**?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American GT-240-NEH 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/)
- [Compare Bosch T9800 SE 160 (0.95 UEF)→](https://gcsradheat.com/water-heaters/bosch/t9800-se-160/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)