title: "A. O. Smith HPS10-66H45DV 2** (3.7 UEF, 67 gal)"
url: https://gcsradheat.com/water-heaters/a-o-smith/hps10-66h45dv-2/
description: "The A. O. Smith HPS10-66H45DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First."
---

ENERGY STAR water heater model · PD 2408845

# A. O. Smith HPS10-66H45DV 2** Water Heater Specifications (3.7 UEF)

The A. O. Smith HPS10-66H45DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating, ranking #347 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408845). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.20 / +48.0%. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10266H045DV 2** (3.7 UEF).

- **Uniform Energy Factor**: 3.7 UEF

- **Cohort UEF Rank**: #347 of 706

- **First Hour Rating**: 82 gal

- **Storage Volume**: 67 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +48.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPS10-66H45DV 2** relative to the cohort median.

Efficiency comparison & rule summary

A. O. Smith HPS10-66H45DV 2** (3.7 UEF) ranks #347 of 706 Hybrid/Electric Heat Pump models — 42-way tie; more efficient than 45% of Hybrid/Electric Heat Pump models, at the 3.70 UEF median.

Federal 2029 margin for A. O. Smith HPS10-66H45DV 2**: +1.20 UEF (+48.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for A. O. Smith HPS10-66H45DV 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPS10-66H45DV 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: A. O. Smith HPS10-66H45DV 2** (3.7 UEF) compares closely with American HPS10266H045DV 2** (3.7 UEF, at parity) and Lochinvar HPSA065KD 2** (3.7 UEF, at parity).

## How Complete Are the Certified Metrics for A. O. Smith HPS10-66H45DV 2**?

Standing at #347 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, A. O. Smith HPS10-66H45DV 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 2408845 |
| Model Number | HPS10-66H45DV 2** | Draw pattern: High-Usage | HPS10-66H45DV 2** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,233 kWh/yr | +161 kWh/yr vs. 1,072 kWh/yr median | Est. $224/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 425% | -4.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## What Is the Projected Utility Bill for HPS10-66H45DV 2** by State?

At 1,233 kWh/yr, A. O. Smith HPS10-66H45DV 2** averages about $224/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $224/yr | $2,239 | $6,766 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $582/yr | $5,817 | $17,579 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $367/yr | $3,668 | $11,085 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,962 | $5,928 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $180/yr | $1,804 | $5,451 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,233 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which 5 Models Offer Similar Output to HPS10-66H45DV 2**?

Ordered by minimal capacity and UEF spread relative to A. O. Smith HPS10-66H45DV 2**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American HPS10266H045DV 2**](https://gcsradheat.com/water-heaters/american/hps10266h045dv-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [Lochinvar HPSA065KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpsa065kd-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [RELIANCE WATER HEATERS 10-66-DHPTS 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-66-dhpts-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [State HPSX-66-DHPT 2**](https://gcsradheat.com/water-heaters/state/hpsx-66-dhpt-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [American HPHE10266H045DVCTA-1**](https://gcsradheat.com/water-heaters/american/hphe10266h045dvcta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (-0.25) | 1,381 |

## Who Is A. O. Smith HPS10-66H45DV 2** Best For — and When Should You Pick American HPS10266H045DV 2**?

Evaluate whether A. O. Smith HPS10-66H45DV 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- A. O. Smith HPS10-66H45DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPS10-66H45DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing A. O. Smith HPS10-66H45DV 2 Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare American HPS10266H045DV 2** footprint.

## Practical Specs & Code Questions for A. O. Smith HPS10-66H45DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does A. O. Smith HPS10-66H45DV 2** (3.7 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith HPS10-66H45DV 2** records 3.7 UEF (Pass: +1.20 / +48.0%), placing #347 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does A. O. Smith HPS10-66H45DV 2** fit inside a tight hallway closet or low-headroom utility room?

A. O. Smith HPS10-66H45DV 2** requires room for its 61 in. vertical shell and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern A. O. Smith HPS10-66H45DV 2**?

For A. O. Smith HPS10-66H45DV 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for A. O. Smith HPS10-66H45DV 2**?

Using 1,233 kWh/yr, A. O. Smith HPS10-66H45DV 2** generates an estimated $224/yr electric bill at 18.16 cents/kWh (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of A. O. Smith HPS10-66H45DV 2** (3.7 UEF)?

A. O. Smith HPS10-66H45DV 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or American HPS10266H045DV 2**.

### What hot-water delivery rating governs A. O. Smith HPS10-66H45DV 2**?

Rated for 82 gal FHR (+10 gal vs. 72 gal median), A. O. Smith HPS10-66H45DV 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen A. O. Smith HPS10-66H45DV 2** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to A. O. Smith HPS10-66H45DV 2** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is American HPS10266H045DV 2** (3.7 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Installation, Serial & DOE 2029 Links for HPS10-66H45DV 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American HPS10266H045DV 2** (3.7 UEF)→](https://gcsradheat.com/water-heaters/american/hps10266h045dv-2/)
- [Compare Lochinvar HPSA065KD 2** (3.7 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/hpsa065kd-2/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)