title: "A. O. Smith HPTS-66 2** (3.7 UEF, 67 gal)"
url: https://gcsradheat.com/water-heaters/a-o-smith/hpts-66-2/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith HPTS-66 2** achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal."
---

ENERGY STAR water heater model · PD 2408852

# A. O. Smith HPTS-66 2** Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith HPTS-66 2** achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 2408852), recording Pass: +1.20 / +48.0% under 2029 DOE rules. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10266H045DV 2** (3.7 UEF).

- **Uniform Energy Factor**: 3.7 UEF

- **Cohort UEF Rank**: #347 of 706

- **First Hour Rating**: 82 gal

- **Storage Volume**: 67 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +48.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTS-66 2** relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, A. O. Smith HPTS-66 2** logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), A. O. Smith HPTS-66 2** holds a +1.20 UEF (+48.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for A. O. Smith HPTS-66 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPTS-66 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping A. O. Smith HPTS-66 2** (3.7 UEF)? Check American HPS10266H045DV 2** (3.7 UEF, at parity) and Lochinvar HPSA065KD 2** (3.7 UEF, at parity).

## How Complete Are the Certified Metrics for A. O. Smith HPTS-66 2**?

Standing at #347 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, A. O. Smith HPTS-66 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 2408852 |
| Model Number | HPTS-66 2** | Draw pattern: High-Usage | HPTS-66 2** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,233 kWh/yr | +161 kWh/yr vs. 1,072 kWh/yr median | Est. $224/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 425% | -4.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |

## What Is the Projected Utility Bill for HPTS-66 2** by State?

At 1,233 kWh/yr, A. O. Smith HPTS-66 2** averages about $224/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $224/yr | $2,239 | $6,766 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $582/yr | $5,817 | $17,579 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $367/yr | $3,668 | $11,085 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,962 | $5,928 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $180/yr | $1,804 | $5,451 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,233 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which 5 Models Offer Similar Output to HPTS-66 2**?

Ordered by minimal capacity and UEF spread relative to A. O. Smith HPTS-66 2**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American HPS10266H045DV 2**](https://gcsradheat.com/water-heaters/american/hps10266h045dv-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [Lochinvar HPSA065KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpsa065kd-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [RELIANCE WATER HEATERS 10-66-DHPTS 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-66-dhpts-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [State HPSX-66-DHPT 2**](https://gcsradheat.com/water-heaters/state/hpsx-66-dhpt-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [American HPHE10266H045DVCTA-1**](https://gcsradheat.com/water-heaters/american/hphe10266h045dvcta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (-0.25) | 1,381 |

## What Installation Caveats Apply Before Buying A. O. Smith HPTS-66 2**?

Even high-UEF units like A. O. Smith HPTS-66 2** (3.7 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- A. O. Smith HPTS-66 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTS-66 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing A. O. Smith HPTS-66 2 Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare American HPS10266H045DV 2** footprint.

## Practical Specs & Code Questions for A. O. Smith HPTS-66 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is A. O. Smith HPTS-66 2** eligible for continued manufacture past May 6, 2029?

At 3.7 UEF, A. O. Smith HPTS-66 2** achieves Pass: +1.20 / +48.0% for the 2029 DOE standard and stands #347 of 706 against American HPS10266H045DV 2** and Lochinvar HPSA065KD 2**.

### How tall and wide is A. O. Smith HPTS-66 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith HPTS-66 2** are 61 in. height and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)); verify stair turns and drain pan width before delivery.

### Will A. O. Smith HPTS-66 2** require upgrading household electrical panels or gas piping?

A. O. Smith HPTS-66 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is A. O. Smith HPTS-66 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $224/yr ($2,240 over 10 years) to power A. O. Smith HPTS-66 2** at 1,233 kWh/yr under the 18.16 cents/kWh US average (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).

### Which installation bottlenecks limit A. O. Smith HPTS-66 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith HPTS-66 2** drops into resistance mode more often.

### How does A. O. Smith HPTS-66 2** handle simultaneous showers and laundry?

Delivering 82 gal in the first hour (+10 gal vs. 72 gal median), A. O. Smith HPTS-66 2** combines 67 gal tank storage with rapid burner/element recovery.

### How long is the warranty on A. O. Smith HPTS-66 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying A. O. Smith HPTS-66 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPS10266H045DV 2** (3.7 UEF).

## Installation, Serial & DOE 2029 Links for HPTS-66 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American HPS10266H045DV 2** (3.7 UEF)→](https://gcsradheat.com/water-heaters/american/hps10266h045dv-2/)
- [Compare Lochinvar HPSA065KD 2** (3.7 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/hpsa065kd-2/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)