title: "A. O. Smith HPV10-50H01DV 2** (3 UEF, 46 gal)"
url: https://gcsradheat.com/water-heaters/a-o-smith/hpv10-50h01dv-2/
description: "In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPV10-50H01DV 2** (Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal."
---

ENERGY STAR water heater model · PD 2862509

# A. O. Smith HPV10-50H01DV 2** Water Heater Specifications (3 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPV10-50H01DV 2** (Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 52 gal First Hour Rating (rank #666 of 706, PD 2862509) and verifies as Pass: +0.70 / +30.4% for 2029 DOE floors. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10250H009DV 2** (3.0 UEF).

- **Uniform Energy Factor**: 3.0 UEF

- **Cohort UEF Rank**: #666 of 706

- **First Hour Rating**: 52 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.70 / +30.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPV10-50H01DV 2** relative to the cohort median.

Efficiency comparison & rule summary

A. O. Smith HPV10-50H01DV 2** records 3.0 UEF efficiency, putting it #666 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith HPV10-50H01DV 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.70 UEF (+30.4%). At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for A. O. Smith HPV10-50H01DV 2** runs ~$281/yr vs. ~$918/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for A. O. Smith HPV10-50H01DV 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith HPV10-50H01DV 2** (3.0 UEF) are American HPV10250H009DV 2** (3.0 UEF, at parity) and Lochinvar HPV050KD 2** (3.0 UEF, at parity).

## Which Specs Set A. O. Smith HPV10-50H01DV 2** Apart From Cohort Averages?

Ranked #666 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPV10-50H01DV 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 2862509 |
| Model Number | HPV10-50H01DV 2** | Draw pattern: Medium-Usage | HPV10-50H01DV 2** |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 52 gal | -20 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,550 kWh/yr | +478 kWh/yr vs. 1,072 kWh/yr median | Est. $281/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 45 dBA | top 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## How Do Regional kWh Prices Impact HPV10-50H01DV 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, A. O. Smith HPV10-50H01DV 2**'s 1,550 kWh/yr draw translates to roughly $281/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $281/yr | $2,815 | $6,363 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $731/yr | $7,313 | $16,532 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $461/yr | $4,611 | $10,424 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $247/yr | $2,466 | $5,575 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $227/yr | $2,268 | $5,126 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,550 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should A. O. Smith Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPV10-50H01DV 2** production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American HPV10250H009DV 2**](https://gcsradheat.com/water-heaters/american/hpv10250h009dv-2/) | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| [Lochinvar HPV050KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpv050kd-2/) | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| [RELIANCE WATER HEATERS 10-50-DHPTV 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-50-dhptv-2/) | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| [State HPVX-50-DHPT 2**](https://gcsradheat.com/water-heaters/state/hpvx-50-dhpt-2/) | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| [Friedrich PROH50 T0 FD120](https://gcsradheat.com/water-heaters/friedrich/proh50-t0-fd120/) | Hybrid/Electric Heat Pump | 46 gal | 51 gal | 3.0 (at parity) | 1,082 |

## What Installation Caveats Apply Before Buying A. O. Smith HPV10-50H01DV 2**?

Even high-UEF units like A. O. Smith HPV10-50H01DV 2** (3.0 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- A. O. Smith HPV10-50H01DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 45 dBA; avoid mounting A. O. Smith HPV10-50H01DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing A. O. Smith HPV10-50H01DV 2 Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare American HPV10250H009DV 2** footprint.

## Frequently Asked Technical Questions: A. O. Smith HPV10-50H01DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is A. O. Smith HPV10-50H01DV 2** eligible for continued manufacture past May 6, 2029?

At 3.0 UEF, A. O. Smith HPV10-50H01DV 2** achieves Pass: +0.70 / +30.4% for the 2029 DOE standard and stands #666 of 706 against American HPV10250H009DV 2** and Lochinvar HPV050KD 2**.

### How tall and wide is A. O. Smith HPV10-50H01DV 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith HPV10-50H01DV 2** are 63 in. height and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)); verify stair turns and drain pan width before delivery.

### Will A. O. Smith HPV10-50H01DV 2** require upgrading household electrical panels or gas piping?

A. O. Smith HPV10-50H01DV 2** draws 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is A. O. Smith HPV10-50H01DV 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $281/yr ($2,810 over 10 years) to power A. O. Smith HPV10-50H01DV 2** at 1,550 kWh/yr under the 18.16 cents/kWh US average (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii).

### Which installation bottlenecks limit A. O. Smith HPV10-50H01DV 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith HPV10-50H01DV 2** drops into resistance mode more often.

### How does A. O. Smith HPV10-50H01DV 2** handle simultaneous showers and laundry?

Delivering 52 gal in the first hour (-20 gal vs. 72 gal median), A. O. Smith HPV10-50H01DV 2** combines 46 gal tank storage with rapid burner/element recovery.

### How long is the warranty on A. O. Smith HPV10-50H01DV 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying A. O. Smith HPV10-50H01DV 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPV10250H009DV 2** (3.0 UEF).

## Essential Pre-Install Guides for A. O. Smith HPV10-50H01DV 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American HPV10250H009DV 2** (3.0 UEF)→](https://gcsradheat.com/water-heaters/american/hpv10250h009dv-2/)
- [Compare Lochinvar HPV050KD 2** (3.0 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/hpv050kd-2/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)