---
title: "A. O. Smith HPV10-80H01DV 2** (3 UEF, 82 gal)"
url: https://gcsradheat.com/water-heaters/a-o-smith/hpv10-80h01dv-2/
description: "With PD 2546243 certification, A. O. Smith HPV10-80H01DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 82-gallon."
---

ENERGY STAR water heater model · PD 2546243

# A. O. Smith HPV10-80H01DV 2** Water Heater Specifications (3 UEF)

With PD 2546243 certification, A. O. Smith HPV10-80H01DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 82-gallon nominal tank, 93 gal First Hour Rating, standing #666 of 706 across 706 peers with Pass: +0.50 / +20.0% for May 6, 2029. Rated annual electricity draw of 1,654 kWh/yr equates to roughly $300/yr ($3,004 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10280H009DV 2** (3.0 UEF).

- **Uniform Energy Factor**: 3.0 UEF

- **Cohort UEF Rank**: #666 of 706

- **First Hour Rating**: 93 gal

- **Storage Volume**: 82 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.50 / +20.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPV10-80H01DV 2** relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places A. O. Smith HPV10-80H01DV 2** at 3.0 UEF (#666 of 706; -0.70 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: A. O. Smith HPV10-80H01DV 2** stands +0.50 UEF (+20.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,654 kWh/yr for A. O. Smith HPV10-80H01DV 2** runs ~$300/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for A. O. Smith HPV10-80H01DV 2**: 10-year operating spend spans $2,420 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,804 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, American HPV10280H009DV 2** (3.0 UEF, at parity) and Lochinvar HPV080KD 2** (3.0 UEF, at parity) bracket A. O. Smith HPV10-80H01DV 2**.

## How Do A. O. Smith HPV10-80H01DV 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

A. O. Smith HPV10-80H01DV 2** places #666 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [A. O. Smith](https://gcsradheat.com/brands/a-o-smith/) | 144 certified listings | ENERGY STAR PD 2546243 |
| Model Number | HPV10-80H01DV 2** | Draw pattern: High-Usage | HPV10-80H01DV 2** |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 93 gal | +21 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,654 kWh/yr | +582 kWh/yr vs. 1,072 kWh/yr median | Est. $300/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 92" H x 27" D | Needs >72 in. overhead clearance; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 45 dBA | top 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## What Does HPV10-80H01DV 2** Cost to Operate Across State Electricity Rates?

At 1,654 kWh/yr, A. O. Smith HPV10-80H01DV 2** runs roughly $300/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $300/yr | $3,004 | $6,790 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $780/yr | $7,804 | $17,641 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $492/yr | $4,921 | $11,124 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $263/yr | $2,632 | $5,949 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $242/yr | $2,420 | $5,470 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,654 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19030 (2018-11-08):** A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-30-Gallon-Gas-Water-Heaters-Due-to-Fire-Hazard-Sold-Exclusively-at-Lowes))
- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match HPV10-80H01DV 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith HPV10-80H01DV 2** by storage capacity and 3.0 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [American HPV10280H009DV 2**](https://gcsradheat.com/water-heaters/american/hpv10280h009dv-2/) | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| [Lochinvar HPV080KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpv080kd-2/) | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| [RELIANCE WATER HEATERS 10-80-DHPTV 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-80-dhptv-2/) | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| [State HPVX-80-DHPT 2**](https://gcsradheat.com/water-heaters/state/hpvx-80-dhpt-2/) | Hybrid/Electric Heat Pump | 82 gal | 93 gal | 3.0 (at parity) | 1,654 |
| [American HPHE10280H045DVCTA-1**](https://gcsradheat.com/water-heaters/american/hphe10280h045dvcta-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (+0.45) | 1,387 |

## What Are the Limitations of A. O. Smith HPV10-80H01DV 2** and Who Should Not Install It?

Before ordering A. O. Smith HPV10-80H01DV 2** (Hybrid/Electric Heat Pump, 3.0 UEF), weigh space clearances, fuel piping, noise (45 dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- A. O. Smith HPV10-80H01DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 45 dBA; avoid mounting A. O. Smith HPV10-80H01DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing A. O. Smith HPV10-80H01DV 2 Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare American HPV10280H009DV 2** footprint.

## What Are the Key Questions About A. O. Smith HPV10-80H01DV 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does A. O. Smith HPV10-80H01DV 2** pass the May 6, 2029 federal DOE efficiency rule?

A. O. Smith HPV10-80H01DV 2** carries a verified 3.0 UEF rating (Pass: +0.50 / +20.0%), ranking #666 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does A. O. Smith HPV10-80H01DV 2** need?

A. O. Smith HPV10-80H01DV 2** stands 92 in. high with a 27 in. diameter; needs >72 in. overhead clearance; tight at 28 in. door (27" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does A. O. Smith HPV10-80H01DV 2** require?

A. O. Smith HPV10-80H01DV 2** uses a 120V branch circuit at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does A. O. Smith HPV10-80H01DV 2** cost per year to run?

Rated at 1,654 kWh/yr, A. O. Smith HPV10-80H01DV 2** costs about $300/yr ($3,000 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $242/yr in Washington hydro tiers up to $780/yr in Hawaii).

### Who should NOT install A. O. Smith HPV10-80H01DV 2**, and what are its limits?

A. O. Smith HPV10-80H01DV 2** (3.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 45 dBA.

### How many bathrooms or people can A. O. Smith HPV10-80H01DV 2** serve at peak demand?

A. O. Smith HPV10-80H01DV 2** achieves a 93 gal First Hour Rating (+21 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for A. O. Smith HPV10-80H01DV 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to A. O. Smith HPV10-80H01DV 2**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American HPV10280H009DV 2** (3.0 UEF).

## Which Sizing and Compliance Guides Pair with HPV10-80H01DV 2**?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare American HPV10280H009DV 2** (3.0 UEF)→](https://gcsradheat.com/water-heaters/american/hpv10280h009dv-2/)
- [Compare Lochinvar HPV080KD 2** (3.0 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/hpv080kd-2/)
- [View All A. O. Smith Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/a-o-smith/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
