title: "Acevedo Unit 2-20 (99 SUEF, 80 gal)"
url: https://gcsradheat.com/water-heaters/acevedo/unit-2-20/
description: "Certified at 99.0 SUEF across its 80-gallon nominal tank, Acevedo Unit 2-20 (Solar with Electric Backup, Solar + Electric Backup) places #1 of 30 out of 30."
---

ENERGY STAR water heater model · PD 2408406

# Acevedo Unit 2-20 Water Heater Specifications (99 SUEF)

Certified at 99.0 SUEF across its 80-gallon nominal tank, Acevedo Unit 2-20 (Solar with Electric Backup, Solar + Electric Backup) places #1 of 30 out of 30 ENERGY STAR models (PD 2408406). Its May 6, 2029 10 CFR 430.32 status reads Exempt — Solar SUEF. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is AET DX-80-64 (99.0 SUEF).

- **Solar UEF (SUEF)**: 99.0 SUEF

- **Cohort SUEF Rank**: #1 of 30 (top 40%)

- **First Hour Rating**: On-Demand

- **Storage Volume**: 80 gal

- **Fuel / Type**: Solar + Electric Backup / Solar with Electric Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows Acevedo Unit 2-20 relative to the cohort median.

Efficiency comparison & rule summary

Tested at 99.0 SUEF, Acevedo Unit 2-20 places #1 of 30 across 30 certified Solar with Electric Backup configurations (+88.15 SUEF vs. 10.85 SUEF median).

Solar collector & storage profile, OG-300 #30004355 for Acevedo Unit 2-20: Direct Thermosyphon architecture; 36.3 sq ft Flat Plate collector; 80 gal storage tank; freeze limit 39 deg F.

Closest alternatives to Acevedo Unit 2-20 include AET DX-80-64 (99.0 SUEF, at parity) alongside Heliodyne HF 1 410 G 80 AC S E (6.6 SUEF, delta -92.40).

## Where Does Acevedo Unit 2-20 Rank Against Peer Solar with Electric Backup Units?

Audited against 30 ENERGY STAR Solar with Electric Backup listings, Acevedo Unit 2-20 holds #1 of 30 (top 40%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Acevedo | 1 certified listing | ENERGY STAR PD 2408406 |
| Model Number | Unit 2-20 | Draw pattern: Low-Usage | Unit 2-20 |
| Solar Uniform Energy Factor (SUEF) | 99.0 | +88.15 SUEF vs. 10.85 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct Thermosyphon (Flat Plate) | 36.3 sq ft aperture | OG-300 #30004355 |
| Collector Freeze Tolerance | 39 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Electrical Circuit Requirements | 240 V | Collector loop pump / controller + backup element check | NEC / Branch circuit check |
| Certification Date | 2021-07-06 | Certified 2021-07-06 | Markets: United States |

## Does CPSC Flag Any Safety Notices on Acevedo Units?

No open CPSC recall alerts appeared for Acevedo as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Solar with Electric Backup Models Compare Closest to Unit 2-20?

Compare five nearby ENERGY STAR Solar with Electric Backup options matched closely to Acevedo Unit 2-20's gallon capacity and 99.0 SUEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [AET DX-80-64](https://gcsradheat.com/water-heaters/aet/dx-80-64/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [Heliodyne HF 1 410 G 80 AC S E](https://gcsradheat.com/water-heaters/heliodyne/hf-1-410-g-80-ac-s-e/) | Solar with Electric Backup | 80 gal | — | 6.6 (-92.40) | — |
| [MC Green A80-20](https://gcsradheat.com/water-heaters/mc-green/a80-20/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [Rheem RS80-40BP](https://gcsradheat.com/water-heaters/rheem/rs80-40bp/) | Solar with Electric Backup | 80 gal | — | 4.8 (-94.20) | — |
| [MC Green B80-20](https://gcsradheat.com/water-heaters/mc-green/b80-20/) | Solar with Electric Backup | 80 gal | — | 23.3 (-75.70) | — |

## What Installation Caveats Apply Before Buying Acevedo Unit 2-20?

Even high-UEF units like Acevedo Unit 2-20 (99.0 SUEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Acevedo Unit 2-20 logs 99.0 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Acevedo Unit 2-20's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 80 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Acevedo Unit 2-20** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like AET DX-80-64.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Common Homeowner Questions for Acevedo Unit 2-20

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Acevedo Unit 2-20 eligible for continued manufacture past May 6, 2029?

Acevedo Unit 2-20 holds 99.0 SUEF certification in the 30-unit Solar with Electric Backup tier, remaining unaffected by the May 6, 2029 electric storage UEF mandate.

### How tall and wide is Acevedo Unit 2-20, and what service clearance is needed?

Acevedo Unit 2-20 saves floor space via its solar with electric backup layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

### Will Acevedo Unit 2-20 require upgrading household electrical panels or gas piping?

Acevedo Unit 2-20 draws 240V (Collector loop pump / controller + backup element check); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Acevedo Unit 2-20 economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Acevedo Unit 2-20 (Solar + Electric Backup, 99.0 SUEF) hinge on household gallon demand and local gas utility tariffs compared with AET DX-80-64.

### Which installation bottlenecks limit Acevedo Unit 2-20?

Check local 10 CFR 430.32(d)(2) phase-in timing (Exempt — Solar SUEF) and physical doorway clearances before choosing Acevedo Unit 2-20 over AET DX-80-64.

### How does Acevedo Unit 2-20 handle simultaneous showers and laundry?

Acevedo Unit 2-20 supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

### How long is the warranty on Acevedo Unit 2-20 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Acevedo as of 2026-11-23. Confirm install proof and serial manufacture year on Acevedo Unit 2-20 before calling service.

### How do 2026 post-OBBBA rebates affect buying Acevedo Unit 2-20?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Solar with Electric Backup is AET DX-80-64 (99.0 SUEF).

## Next Engineering Checks for Acevedo Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare AET DX-80-64 (99.0 SUEF)→](https://gcsradheat.com/water-heaters/aet/dx-80-64/)
- [Compare Heliodyne HF 1 410 G 80 AC S E (6.6 SUEF)→](https://gcsradheat.com/water-heaters/heliodyne/hf-1-410-g-80-ac-s-e/)
- [View All Acevedo Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Check SRCC collector freeze protection, backup tank wiring, and available post-OBBBA state DOE HEAR / utility solar incentives before replacement.
[Check 2026 State Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Model Replacement Labor](https://gcsradheat.com/costs/water-heater-replacement/)