title: "AET DX-80-64 (99 SUEF, 80 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/aet/dx-80-64/
description: "Certified at 99.0 SUEF across its 80-gallon nominal tank, AET DX-80-64 (Solar with Electric Backup, Solar + Electric Backup) places #1 of 30 out of 30 ENERGY."
---

ENERGY STAR water heater model · PD 2407946

# AET DX-80-64 Water Heater Specifications (99 SUEF)

Certified at 99.0 SUEF across its 80-gallon nominal tank, AET DX-80-64 (Solar with Electric Backup, Solar + Electric Backup) places #1 of 30 out of 30 ENERGY STAR models (PD 2407946). Its May 6, 2029 10 CFR 430.32 status reads Exempt — Solar SUEF. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Acevedo Unit 2-20 (99.0 SUEF).

- **Solar UEF (SUEF)**: 99.0 SUEF

- **Cohort SUEF Rank**: #1 of 30 (top 40%)

- **First Hour Rating**: On-Demand

- **Storage Volume**: 80 gal

- **Fuel / Type**: Solar + Electric Backup / Solar with Electric Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows AET DX-80-64 relative to the cohort median.

Efficiency comparison & rule summary

Tested at 99.0 SUEF, AET DX-80-64 places #1 of 30 across 30 certified Solar with Electric Backup configurations (+88.15 SUEF vs. 10.85 SUEF median).

Solar collector & storage profile, OG-300 #2006007C for AET DX-80-64: Indirect Forced Circulation architecture; 65.3 sq ft Flat Plate collector; 80 gal storage tank; freeze limit -58 deg F.

Closest alternatives to AET DX-80-64 include Acevedo Unit 2-20 (99.0 SUEF, at parity) alongside Heliodyne HF 1 410 G 80 AC S E (6.6 SUEF, delta -92.40).

## Which Specs Set AET DX-80-64 Apart From Cohort Averages?

Ranked #1 of 30 (top 40%) inside the 30-model Solar with Electric Backup cohort, AET DX-80-64 is evaluated row by row below against category medians.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [AET](https://gcsradheat.com/brands/aet/) | 7 certified listings | ENERGY STAR PD 2407946 |
| Model Number | DX-80-64 | Draw pattern: High-Usage | DX-80-64 |
| Solar Uniform Energy Factor (SUEF) | 99.0 | +88.15 SUEF vs. 10.85 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Indirect Forced Circulation (Flat Plate) | 65.3 sq ft aperture | OG-300 #2006007C |
| Collector Freeze Tolerance | -58 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Electrical Circuit Requirements | 240 V | Collector loop pump / controller + backup element check | NEC / Branch circuit check |
| Certification Date | 2019-11-12 | Certified 2019-11-12 | Markets: United States |

## What Should AET Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for AET; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Solar with Electric Backup Models Stack Up?

Five alternative Solar with Electric Backup units with nearly identical gallon storage and SUEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Acevedo Unit 2-20](https://gcsradheat.com/water-heaters/acevedo/unit-2-20/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [Heliodyne HF 1 410 G 80 AC S E](https://gcsradheat.com/water-heaters/heliodyne/hf-1-410-g-80-ac-s-e/) | Solar with Electric Backup | 80 gal | — | 6.6 (-92.40) | — |
| [MC Green A80-20](https://gcsradheat.com/water-heaters/mc-green/a80-20/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [Rheem RS80-40BP](https://gcsradheat.com/water-heaters/rheem/rs80-40bp/) | Solar with Electric Backup | 80 gal | — | 4.8 (-94.20) | — |
| [MC Green B80-20](https://gcsradheat.com/water-heaters/mc-green/b80-20/) | Solar with Electric Backup | 80 gal | — | 23.3 (-75.70) | — |

## When Should Homeowners Skip AET DX-80-64 (Solar with Electric Backup)?

Check AET DX-80-64's mechanical constraints—including utility space, Solar + Electric Backup capacity, and Exempt — Solar SUEF status—against typical residential installations.

### Key Limitations & Exclusions

- AET DX-80-64 logs 99.0 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect AET DX-80-64's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 80 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for AET DX-80-64** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Acevedo Unit 2-20.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Frequently Asked Technical Questions: AET DX-80-64

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will AET DX-80-64 stay compliant after the May 6, 2029 DOE standard takes effect?

Rated at 99.0 SUEF, AET DX-80-64 uses SRCC solar collector physics exempt from the May 6, 2029 tank UEF rules, keeping it compliant alongside Acevedo Unit 2-20.

### Will AET DX-80-64 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted solar with electric backup chassis, AET DX-80-64 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

### Do existing utility hookups support AET DX-80-64 during replacement?

Electrical specs for AET DX-80-64 call for 240V (Collector loop pump / controller + backup element check). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for AET DX-80-64?

Because AET DX-80-64 burns Solar + Electric Backup at 99.0 SUEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 30 peers.

### When is AET DX-80-64 a poor fit for a residential replacement?

Avoid AET DX-80-64 if household peak demand surpasses 80 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

### What First Hour Rating or flow capacity does AET DX-80-64 deliver?

As an on-demand Solar with Electric Backup model, AET DX-80-64 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

### How do you verify manufacturing age and recall status on AET DX-80-64?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for AET; verify exact manufacturing week for AET DX-80-64 using the Serial Number Lookup tool.

### Does AET DX-80-64 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for AET DX-80-64. Closest peer in Solar with Electric Backup is Acevedo Unit 2-20 (99.0 SUEF).

## Essential Pre-Install Guides for AET DX-80-64

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Acevedo Unit 2-20 (99.0 SUEF)→](https://gcsradheat.com/water-heaters/acevedo/unit-2-20/)
- [Compare Heliodyne HF 1 410 G 80 AC S E (6.6 SUEF)→](https://gcsradheat.com/water-heaters/heliodyne/hf-1-410-g-80-ac-s-e/)
- [View All AET Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/aet/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Check SRCC collector freeze protection, backup tank wiring, and available post-OBBBA state DOE HEAR / utility solar incentives before replacement.
[Check 2026 State Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Model Replacement Labor](https://gcsradheat.com/costs/water-heater-replacement/)