title: "AET FF-80-42 (6.7 SUEF, 50 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/aet/ff-80-42/
description: "Certified at 6.7 SUEF across its 50-gallon nominal tank, AET FF-80-42 (Solar with Electric Backup, Solar + Electric Backup) places #19 of 30 out of 30 ENERGY."
---

ENERGY STAR water heater model · PD 2407986

# AET FF-80-42 Water Heater Specifications (6.7 SUEF)

Certified at 6.7 SUEF across its 50-gallon nominal tank, AET FF-80-42 (Solar with Electric Backup, Solar + Electric Backup) places #19 of 30 out of 30 ENERGY STAR models (PD 2407986). Its May 6, 2029 10 CFR 430.32 status reads Exempt — Solar SUEF. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is GREENoneTEC L-Extra (3.3 SUEF).

- **Solar UEF (SUEF)**: 6.7 SUEF

- **Cohort SUEF Rank**: #19 of 30

- **First Hour Rating**: On-Demand

- **Storage Volume**: 50 gal

- **Fuel / Type**: Solar + Electric Backup / Solar with Electric Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows AET FF-80-42 relative to the cohort median.

Efficiency comparison & rule summary

Tested at 6.7 SUEF, AET FF-80-42 places #19 of 30 across 30 certified Solar with Electric Backup configurations (-4.15 SUEF vs. 10.85 SUEF median).

Solar collector & storage profile, OG-300 #2011052D for AET FF-80-42: Direct Thermosyphon architecture; 43 sq ft Flat Plate collector; 50 gal storage tank; freeze limit -58 deg F.

Closest alternatives to AET FF-80-42 include GREENoneTEC L-Extra (3.3 SUEF, delta -3.40) alongside Solahart 181BTC (99.0 SUEF, delta +92.30).

## How Complete Are the Certified Metrics for AET FF-80-42?

Standing at #19 of 30 among 30 certified Solar with Electric Backup heaters, AET FF-80-42 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [AET](https://gcsradheat.com/brands/aet/) | 7 certified listings | ENERGY STAR PD 2407986 |
| Model Number | FF-80-42 | Draw pattern: Medium-Usage | FF-80-42 |
| Solar Uniform Energy Factor (SUEF) | 6.7 | -4.15 SUEF vs. 10.85 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct Thermosyphon (Flat Plate) | 43 sq ft aperture | OG-300 #2011052D |
| Collector Freeze Tolerance | -58 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Electrical Circuit Requirements | 240 V | Collector loop pump / controller + backup element check | NEC / Branch circuit check |
| Certification Date | 2019-11-12 | Certified 2019-11-12 | Markets: United States |

## Are AET Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched AET in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to FF-80-42?

Ordered by minimal capacity and SUEF spread relative to AET FF-80-42, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [GREENoneTEC L-Extra](https://gcsradheat.com/water-heaters/greenonetec/l-extra/) | Solar with Electric Backup | 51 gal | — | 3.3 (-3.40) | — |
| [Solahart 181BTC](https://gcsradheat.com/water-heaters/solahart/181btc/) | Solar with Electric Backup | 48 gal | — | 99.0 (+92.30) | — |
| [Heliodyne HF 1 406 G 40 AC S E](https://gcsradheat.com/water-heaters/heliodyne/hf-1-406-g-40-ac-s-e/) | Solar with Electric Backup | 40 gal | — | 3.3 (-3.40) | — |
| [Dimas 300-2](https://gcsradheat.com/water-heaters/dimas/300-2/) | Solar with Electric Backup | 79 gal | — | 99.0 (+92.30) | — |
| [GREENoneTEC Double E](https://gcsradheat.com/water-heaters/greenonetec/double-e/) | Solar with Electric Backup | 52 gal | — | 3.3 (-3.40) | — |

## What Installation Caveats Apply Before Buying AET FF-80-42?

Even high-UEF units like AET FF-80-42 (6.7 SUEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- AET FF-80-42 logs 6.7 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect AET FF-80-42's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 50 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for AET FF-80-42** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like GREENoneTEC L-Extra.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Practical Specs & Code Questions for AET FF-80-42

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is AET FF-80-42 eligible for continued manufacture past May 6, 2029?

AET FF-80-42 holds 6.7 SUEF certification in the 30-unit Solar with Electric Backup tier, remaining unaffected by the May 6, 2029 electric storage UEF mandate.

### How tall and wide is AET FF-80-42, and what service clearance is needed?

AET FF-80-42 saves floor space via its solar with electric backup layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

### Will AET FF-80-42 require upgrading household electrical panels or gas piping?

AET FF-80-42 draws 240V (Collector loop pump / controller + backup element check); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is AET FF-80-42 economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for AET FF-80-42 (Solar + Electric Backup, 6.7 SUEF) hinge on household gallon demand and local gas utility tariffs compared with GREENoneTEC L-Extra.

### Which installation bottlenecks limit AET FF-80-42?

Check local 10 CFR 430.32(d)(2) phase-in timing (Exempt — Solar SUEF) and physical doorway clearances before choosing AET FF-80-42 over GREENoneTEC L-Extra.

### How does AET FF-80-42 handle simultaneous showers and laundry?

AET FF-80-42 supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

### How long is the warranty on AET FF-80-42 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for AET as of 2026-11-23. Confirm install proof and serial manufacture year on AET FF-80-42 before calling service.

### How do 2026 post-OBBBA rebates affect buying AET FF-80-42?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Solar with Electric Backup is GREENoneTEC L-Extra (3.3 SUEF).

## Installation, Serial & DOE 2029 Links for FF-80-42

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare GREENoneTEC L-Extra (3.3 SUEF)→](https://gcsradheat.com/water-heaters/greenonetec/l-extra/)
- [Compare Solahart 181BTC (99.0 SUEF)→](https://gcsradheat.com/water-heaters/solahart/181btc/)
- [View All AET Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/aet/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Check SRCC collector freeze protection, backup tank wiring, and available post-OBBBA state DOE HEAR / utility solar incentives before replacement.
[Check 2026 State Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Model Replacement Labor](https://gcsradheat.com/costs/water-heater-replacement/)