title: "AMERICAN STANDARD WATER HEATERS ASHPWH-40***** (3.58 UEF, 37"
url: https://gcsradheat.com/water-heaters/american-standard-water-heaters/ashpwh-40/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-40***** achieves a certified 3.58 UEF rating across its."
---

ENERGY STAR water heater model · PD 2853327

# AMERICAN STANDARD WATER HEATERS ASHPWH-40* Water Heater Specifications (3.58 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-40* achieves a certified 3.58 UEF rating across its 37-gallon nominal tank, 66 gal First Hour Rating and ranks #412 of 706 in its 706-model cohort (PD 2853327), recording Pass: +1.28 / +55.7% under 2029 DOE rules. Rated annual electricity draw of 907 kWh/yr equates to roughly $165/yr ($1,647 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-40 (3.58 UEF).

- **Uniform Energy Factor**: 3.58 UEF

- **Cohort UEF Rank**: #412 of 706

- **First Hour Rating**: 66 gal

- **Storage Volume**: 37 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.28 / +55.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows AMERICAN STANDARD WATER HEATERS ASHPWH-40* relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-40* logs 3.58 UEF and ranks #412 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), AMERICAN STANDARD WATER HEATERS ASHPWH-40* holds a +1.28 UEF (+55.7%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 907 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-40* runs ~$165/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-40*: 10-year operating spend spans $1,327 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,279 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-40* (3.58 UEF)? Check Ariston ARIHPWH-40 (3.58 UEF, at parity) and Lennox WHHP040T45MD240S (3.55 UEF, delta -0.03).

## How Do AMERICAN STANDARD WATER HEATERS ASHPWH-40* Specs Compare to Hybrid/Electric Heat Pump Medians?

AMERICAN STANDARD WATER HEATERS ASHPWH-40* places #412 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [AMERICAN STANDARD WATER HEATERS](https://gcsradheat.com/brands/american-standard-water-heaters/) | 4 certified listings | ENERGY STAR PD 2853327 |
| Model Number | ASHPWH-40* | Draw pattern: Medium-Usage | ASHPWH-40* |
| Uniform Energy Factor (UEF) | 3.58 | -0.12 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 907 kWh/yr | -165 kWh/yr vs. 1,072 kWh/yr median | Est. $165/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 402% | -27.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 37.6" H x 18.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-10 | Certified 2026-02-10 | Markets: United States, Canada |

## What Does ASHPWH-40* Cost to Operate Across State Electricity Rates?

At 907 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-40* runs roughly $165/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $165/yr | $1,647 | $4,762 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $428/yr | $4,279 | $12,371 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $270/yr | $2,698 | $7,800 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,443 | $4,172 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $133/yr | $1,327 | $3,836 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (907 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for AMERICAN STANDARD WATER HEATERS Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with AMERICAN STANDARD WATER HEATERS; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match ASHPWH-40* Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to AMERICAN STANDARD WATER HEATERS ASHPWH-40* by storage capacity and 3.58 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Ariston ARIHPWH-40](https://gcsradheat.com/water-heaters/ariston/arihpwh-40/) | Hybrid/Electric Heat Pump | 37 gal | 66 gal | 3.58 (at parity) | 907 |
| [Lennox WHHP040T45MD240S](https://gcsradheat.com/water-heaters/lennox/whhp040t45md240s/) | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (-0.03) | 915 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.02) | 902 |
| [American HPA10240H045DV 2**](https://gcsradheat.com/water-heaters/american/hpa10240h045dv-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.02) | 902 |
| [Ariston ARIHPWH-40-T](https://gcsradheat.com/water-heaters/ariston/arihpwh-40-t/) | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (-0.03) | 915 |

## What Are the Limitations of AMERICAN STANDARD WATER HEATERS ASHPWH-40* and Who Should Not Install It?

Before ordering AMERICAN STANDARD WATER HEATERS ASHPWH-40* (Hybrid/Electric Heat Pump, 3.58 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- AMERICAN STANDARD WATER HEATERS ASHPWH-40* needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-40* directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing AMERICAN STANDARD WATER HEATERS ASHPWH-40*** Strong Fit — 3.58 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Ariston ARIHPWH-40 footprint.

## What Are the Key Questions About AMERICAN STANDARD WATER HEATERS ASHPWH-40*?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does AMERICAN STANDARD WATER HEATERS ASHPWH-40* pass the May 6, 2029 federal DOE efficiency rule?

AMERICAN STANDARD WATER HEATERS ASHPWH-40* carries a verified 3.58 UEF rating (Pass: +1.28 / +55.7%), ranking #412 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does AMERICAN STANDARD WATER HEATERS ASHPWH-40* need?

AMERICAN STANDARD WATER HEATERS ASHPWH-40* stands 37.6 in. high with a 18.2 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does AMERICAN STANDARD WATER HEATERS ASHPWH-40* require?

AMERICAN STANDARD WATER HEATERS ASHPWH-40* uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does AMERICAN STANDARD WATER HEATERS ASHPWH-40* cost per year to run?

Rated at 907 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-40* costs about $165/yr ($1,650 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $133/yr in Washington hydro tiers up to $428/yr in Hawaii).

### Who should NOT install AMERICAN STANDARD WATER HEATERS ASHPWH-40*, and what are its limits?

AMERICAN STANDARD WATER HEATERS ASHPWH-40* (3.58 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can AMERICAN STANDARD WATER HEATERS ASHPWH-40* serve at peak demand?

AMERICAN STANDARD WATER HEATERS ASHPWH-40* achieves a 66 gal First Hour Rating (-6 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for AMERICAN STANDARD WATER HEATERS ASHPWH-40*?

CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to AMERICAN STANDARD WATER HEATERS ASHPWH-40*, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-40 (3.58 UEF).

## Which Sizing and Compliance Guides Pair with ASHPWH-40*?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Ariston ARIHPWH-40 (3.58 UEF)→](https://gcsradheat.com/water-heaters/ariston/arihpwh-40/)
- [Compare Lennox WHHP040T45MD240S (3.55 UEF)→](https://gcsradheat.com/water-heaters/lennox/whhp040t45md240s/)
- [View All AMERICAN STANDARD WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american-standard-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)