title: "AMERICAN STANDARD WATER HEATERS ASHPWH-50***** (3.75 UEF, 45"
url: https://gcsradheat.com/water-heaters/american-standard-water-heaters/ashpwh-50/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-50***** achieves a certified 3.75 UEF rating across its."
---

ENERGY STAR water heater model · PD 2408487

# AMERICAN STANDARD WATER HEATERS ASHPWH-50* Water Heater Specifications (3.75 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-50* achieves a certified 3.75 UEF rating across its 45-gallon nominal tank, 68 gal First Hour Rating and ranks #297 of 706 in its 706-model cohort (PD 2408487), recording Pass: +1.45 / +63.0% under 2029 DOE rules. Rated annual electricity draw of 867 kWh/yr equates to roughly $157/yr ($1,574 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-50 (3.75 UEF).

- **Uniform Energy Factor**: 3.75 UEF

- **Cohort UEF Rank**: #297 of 706

- **First Hour Rating**: 68 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.45 / +63.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows AMERICAN STANDARD WATER HEATERS ASHPWH-50* relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-50* logs 3.75 UEF and ranks #297 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), AMERICAN STANDARD WATER HEATERS ASHPWH-50* holds a +1.45 UEF (+63.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 867 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-50* runs ~$157/yr vs. ~$642/yr for a 0.92 UEF electric tank.

State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-50*: 10-year operating spend spans $1,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,091 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-50* (3.75 UEF)? Check Ariston ARIHPWH-50 (3.75 UEF, at parity) and Friedrich PROH50 T2 FD400-15 (3.75 UEF, at parity).

## Where Does AMERICAN STANDARD WATER HEATERS ASHPWH-50* Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, AMERICAN STANDARD WATER HEATERS ASHPWH-50* holds #297 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [AMERICAN STANDARD WATER HEATERS](https://gcsradheat.com/brands/american-standard-water-heaters/) | 4 certified listings | ENERGY STAR PD 2408487 |
| Model Number | ASHPWH-50* | Draw pattern: Medium-Usage | ASHPWH-50* |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 68 gal | -4 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 867 kWh/yr | -205 kWh/yr vs. 1,072 kWh/yr median | Est. $157/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.8" H x 18.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-04 | Certified 2026-02-04 | Markets: United States, Canada |

## How Much Electricity Does ASHPWH-50* Use in Different States?

Estimated at $157/yr nationally (867 kWh/yr), 10-year utility spending for AMERICAN STANDARD WATER HEATERS ASHPWH-50* shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $157/yr | $1,574 | $4,843 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $409/yr | $4,091 | $12,583 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $258/yr | $2,579 | $7,934 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $138/yr | $1,379 | $4,243 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $127/yr | $1,268 | $3,902 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (867 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on AMERICAN STANDARD WATER HEATERS Units?

Checking 2026-11-23 SaferProducts data shows 2 notices mentioning AMERICAN STANDARD WATER HEATERS; always cross-reference affected serial prefixes before ordering components. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ASHPWH-50*?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to AMERICAN STANDARD WATER HEATERS ASHPWH-50*'s gallon capacity and 3.75 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Ariston ARIHPWH-50](https://gcsradheat.com/water-heaters/ariston/arihpwh-50/) | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.75 (at parity) | 867 |
| [Friedrich PROH50 T2 FD400-15](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-15/) | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| [Rheem CPROPH50 T2 RH400-15](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh400-15/) | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| [Richmond 10CE50-HP5U15](https://gcsradheat.com/water-heaters/richmond/10ce50-hp5u15/) | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| [Rheem CXE50T10H22U1](https://gcsradheat.com/water-heaters/rheem/cxe50t10h22u1/) | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |

## What Are the Limitations of AMERICAN STANDARD WATER HEATERS ASHPWH-50* and Who Should Not Install It?

Before ordering AMERICAN STANDARD WATER HEATERS ASHPWH-50* (Hybrid/Electric Heat Pump, 3.75 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- AMERICAN STANDARD WATER HEATERS ASHPWH-50* needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-50* directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing AMERICAN STANDARD WATER HEATERS ASHPWH-50*** Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Ariston ARIHPWH-50 footprint.

## Common Homeowner Questions for AMERICAN STANDARD WATER HEATERS ASHPWH-50*

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does AMERICAN STANDARD WATER HEATERS ASHPWH-50* pass the May 6, 2029 federal DOE efficiency rule?

AMERICAN STANDARD WATER HEATERS ASHPWH-50* carries a verified 3.75 UEF rating (Pass: +1.45 / +63.0%), ranking #297 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does AMERICAN STANDARD WATER HEATERS ASHPWH-50* need?

AMERICAN STANDARD WATER HEATERS ASHPWH-50* stands 45.8 in. high with a 18.2 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does AMERICAN STANDARD WATER HEATERS ASHPWH-50* require?

AMERICAN STANDARD WATER HEATERS ASHPWH-50* uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does AMERICAN STANDARD WATER HEATERS ASHPWH-50* cost per year to run?

Rated at 867 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-50* costs about $157/yr ($1,570 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $127/yr in Washington hydro tiers up to $409/yr in Hawaii).

### Who should NOT install AMERICAN STANDARD WATER HEATERS ASHPWH-50*, and what are its limits?

AMERICAN STANDARD WATER HEATERS ASHPWH-50* (3.75 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can AMERICAN STANDARD WATER HEATERS ASHPWH-50* serve at peak demand?

AMERICAN STANDARD WATER HEATERS ASHPWH-50* achieves a 68 gal First Hour Rating (-4 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for AMERICAN STANDARD WATER HEATERS ASHPWH-50*?

CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to AMERICAN STANDARD WATER HEATERS ASHPWH-50*, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-50 (3.75 UEF).

## Next Engineering Checks for AMERICAN STANDARD WATER HEATERS Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Ariston ARIHPWH-50 (3.75 UEF)→](https://gcsradheat.com/water-heaters/ariston/arihpwh-50/)
- [Compare Friedrich PROH50 T2 FD400-15 (3.75 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-15/)
- [View All AMERICAN STANDARD WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american-standard-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)