title: "American HPA10266H045DV 2** (3.84 UEF, 68 gal)"
url: https://gcsradheat.com/water-heaters/american/hpa10266h045dv-2/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, American HPA10266H045DV 2** achieves a certified 3.84 UEF rating across its 68-gallon nominal tank, 83."
---

ENERGY STAR water heater model · PD 3417702

# American HPA10266H045DV 2** Water Heater Specifications (3.84 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, American HPA10266H045DV 2** achieves a certified 3.84 UEF rating across its 68-gallon nominal tank, 83 gal First Hour Rating and ranks #221 of 706 in its 706-model cohort (PD 3417702), recording Pass: +1.34 / +53.6% under 2029 DOE rules. Rated annual electricity draw of 1,292 kWh/yr equates to roughly $235/yr ($2,346 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-66 2** (3.84 UEF).

- **Uniform Energy Factor**: 3.84 UEF

- **Cohort UEF Rank**: #221 of 706 (top 32.4%)

- **First Hour Rating**: 83 gal

- **Storage Volume**: 68 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.34 / +53.6%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPA10266H045DV 2** relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, American HPA10266H045DV 2** logs 3.84 UEF and ranks #221 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), American HPA10266H045DV 2** holds a +1.34 UEF (+53.6%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,292 kWh/yr for American HPA10266H045DV 2** runs ~$235/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPA10266H045DV 2**: 10-year operating spend spans $1,890 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,096 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping American HPA10266H045DV 2** (3.84 UEF)? Check A. O. Smith CAHP-66 2** (3.84 UEF, at parity) and Lochinvar CHPA-66 2** (3.84 UEF, at parity).

## What Physical and Thermal Ratings Define American HPA10266H045DV 2**?

Positioning at #221 of 706 (top 32.4%) out of 706 Hybrid/Electric Heat Pump peers, American HPA10266H045DV 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [American](https://gcsradheat.com/brands/american/) | 79 certified listings | ENERGY STAR PD 3417702 |
| Model Number | HPA10266H045DV 2** | Draw pattern: High-Usage | HPA10266H045DV 2** |
| Uniform Energy Factor (UEF) | 3.84 | +0.14 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 83 gal | +11 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,292 kWh/yr | +220 kWh/yr vs. 1,072 kWh/yr median | Est. $235/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## Why Do State Utility Rates Shift HPA10266H045DV 2** Running Costs?

Consuming 1,292 kWh annually puts American HPA10266H045DV 2** near $235/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $235/yr | $2,346 | $7,447 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $610/yr | $6,096 | $19,349 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $384/yr | $3,844 | $12,200 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $206/yr | $2,056 | $6,525 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $189/yr | $1,890 | $6,000 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,292 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any American Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## What Are 5 Direct Alternatives to American HPA10266H045DV 2**?

Homeowners cross-shopping American HPA10266H045DV 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith CAHP-66 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-66-2/) | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| [Lochinvar CHPA-66 2**](https://gcsradheat.com/water-heaters/lochinvar/chpa-66-2/) | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| [RELIANCE WATER HEATERS 10-66-DHPTA 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-66-dhpta-2/) | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| [State CSHP-66 2**](https://gcsradheat.com/water-heaters/state/cshp-66-2/) | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |
| [A. O. Smith HPA10-66H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpa10-66h45dv-2/) | Hybrid/Electric Heat Pump | 68 gal | 83 gal | 3.84 (at parity) | 1,292 |

## What Are the Limitations of American HPA10266H045DV 2** and Who Should Not Install It?

Before ordering American HPA10266H045DV 2** (Hybrid/Electric Heat Pump, 3.84 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- American HPA10266H045DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPA10266H045DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing American HPA10266H045DV 2 Strong Fit — 3.84 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith CAHP-66 2** footprint.

## Sizing, Efficiency & Recall Answers for American HPA10266H045DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does American HPA10266H045DV 2** pass the May 6, 2029 federal DOE efficiency rule?

American HPA10266H045DV 2** carries a verified 3.84 UEF rating (Pass: +1.34 / +53.6%), ranking #221 of 706 (top 32.4%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does American HPA10266H045DV 2** need?

American HPA10266H045DV 2** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does American HPA10266H045DV 2** require?

American HPA10266H045DV 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does American HPA10266H045DV 2** cost per year to run?

Rated at 1,292 kWh/yr, American HPA10266H045DV 2** costs about $235/yr ($2,350 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $189/yr in Washington hydro tiers up to $610/yr in Hawaii).

### Who should NOT install American HPA10266H045DV 2**, and what are its limits?

American HPA10266H045DV 2** (3.84 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can American HPA10266H045DV 2** serve at peak demand?

American HPA10266H045DV 2** achieves a 83 gal First Hour Rating (+11 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for American HPA10266H045DV 2**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to American HPA10266H045DV 2**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-66 2** (3.84 UEF).

## Related Rebate, Gas-Line & Serial Tools for HPA10266H045DV 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith CAHP-66 2** (3.84 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/cahp-66-2/)
- [Compare Lochinvar CHPA-66 2** (3.84 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/chpa-66-2/)
- [View All American Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)