title: "American HPHE10280H045DVCTA-1** (3.45 UEF, 82 gal)"
url: https://gcsradheat.com/water-heaters/american/hphe10280h045dvcta-1/
description: "With PD 2408858 certification, American HPHE10280H045DVCTA-1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 82-gallon."
---

ENERGY STAR water heater model · PD 2408858

# American HPHE10280H045DVCTA-1** Water Heater Specifications (3.45 UEF)

With PD 2408858 certification, American HPHE10280H045DVCTA-1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 86 gal First Hour Rating, standing #563 of 706 across 706 peers with Pass: +0.95 / +38.0% for May 6, 2029. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1080H45DV 1** (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 86 gal

- **Storage Volume**: 82 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.95 / +38.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPHE10280H045DVCTA-1** relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places American HPHE10280H045DVCTA-1** at 3.45 UEF (#563 of 706; -0.25 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: American HPHE10280H045DVCTA-1** stands +0.95 UEF (+38.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for American HPHE10280H045DVCTA-1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPHE10280H045DVCTA-1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HP1080H45DV 1** (3.45 UEF, at parity) and Lochinvar HPA082KD 1** (3.45 UEF, at parity) bracket American HPHE10280H045DVCTA-1**.

## How Do American HPHE10280H045DVCTA-1** Specs Compare to Hybrid/Electric Heat Pump Medians?

American HPHE10280H045DVCTA-1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [American](https://gcsradheat.com/brands/american/) | 79 certified listings | ENERGY STAR PD 2408858 |
| Model Number | HPHE10280H045DVCTA-1** | Draw pattern: High-Usage | HPHE10280H045DVCTA-1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,387 kWh/yr | +315 kWh/yr vs. 1,072 kWh/yr median | Est. $252/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 233% | -196.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |

## What Does HPHE10280H045DVCTA-1** Cost to Operate Across State Electricity Rates?

At 1,387 kWh/yr, American HPHE10280H045DVCTA-1** runs roughly $252/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $252/yr | $2,519 | $6,926 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $654/yr | $6,544 | $17,994 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $413/yr | $4,126 | $11,347 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $221/yr | $2,207 | $6,068 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $203/yr | $2,029 | $5,580 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,387 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for American Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with American; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match HPHE10280H045DVCTA-1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to American HPHE10280H045DVCTA-1** by storage capacity and 3.45 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HP1080H45DV 1**](https://gcsradheat.com/water-heaters/a-o-smith/hp1080h45dv-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| [Lochinvar HPA082KD 1**](https://gcsradheat.com/water-heaters/lochinvar/hpa082kd-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| [RELIANCE WATER HEATERS 10-80-DHPHTCTA 1**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-80-dhphtcta-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| [State HPX-80-DHPTCTA 1**](https://gcsradheat.com/water-heaters/state/hpx-80-dhptcta-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| [A. O. Smith HP1080H45DVCTA-1**](https://gcsradheat.com/water-heaters/a-o-smith/hp1080h45dvcta-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |

## When Should Homeowners Skip American HPHE10280H045DVCTA-1** (Hybrid/Electric Heat Pump)?

Check American HPHE10280H045DVCTA-1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.95 / +38.0% status—against typical residential installations.

### Key Limitations & Exclusions

- American HPHE10280H045DVCTA-1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPHE10280H045DVCTA-1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing American HPHE10280H045DVCTA-1 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HP1080H45DV 1** footprint.

## What Are the Key Questions About American HPHE10280H045DVCTA-1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will American HPHE10280H045DVCTA-1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.45 UEF, American HPHE10280H045DVCTA-1** shows Pass: +0.95 / +38.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HP1080H45DV 1**.

### Will American HPHE10280H045DVCTA-1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 69 in. tall by 27 in. diameter, American HPHE10280H045DVCTA-1** notes: verify 72 in. vertical headroom; tight at 28 in. door (27" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support American HPHE10280H045DVCTA-1** during replacement?

Electrical specs for American HPHE10280H045DVCTA-1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for American HPHE10280H045DVCTA-1**?

At 18.16 cents/kWh national residential pricing, American HPHE10280H045DVCTA-1**'s 1,387 kWh/yr draw equals roughly $252 annually or $2,520 across a 10-year horizon (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii).

### When is American HPHE10280H045DVCTA-1** a poor fit for a residential replacement?

Avoid placing American HPHE10280H045DVCTA-1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does American HPHE10280H045DVCTA-1** deliver?

With 86 gal FHR (+14 gal vs. 72 gal median), American HPHE10280H045DVCTA-1** fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on American HPHE10280H045DVCTA-1**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Does American HPHE10280H045DVCTA-1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPHE10280H045DVCTA-1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1080H45DV 1** (3.45 UEF).

## Which Sizing and Compliance Guides Pair with HPHE10280H045DVCTA-1**?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HP1080H45DV 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hp1080h45dv-1/)
- [Compare Lochinvar HPA082KD 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/hpa082kd-1/)
- [View All American Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)