title: "American HPS10266H045DV 2** (3.7 UEF, 67 gal)"
url: https://gcsradheat.com/water-heaters/american/hps10266h045dv-2/
description: "The American HPS10266H045DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour."
---

ENERGY STAR water heater model · PD 2408850

# American HPS10266H045DV 2** Water Heater Specifications (3.7 UEF)

The American HPS10266H045DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 67-gallon nominal tank, 82 gal First Hour Rating, ranking #347 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408850). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.20 / +48.0%. Rated annual electricity draw of 1,233 kWh/yr equates to roughly $224/yr ($2,239 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

- **Uniform Energy Factor**: 3.7 UEF

- **Cohort UEF Rank**: #347 of 706

- **First Hour Rating**: 82 gal

- **Storage Volume**: 67 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +48.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPS10266H045DV 2** relative to the cohort median.

Efficiency comparison & rule summary

American HPS10266H045DV 2** (3.7 UEF) ranks #347 of 706 Hybrid/Electric Heat Pump models — 42-way tie; more efficient than 45% of Hybrid/Electric Heat Pump models, at the 3.70 UEF median.

Federal 2029 margin for American HPS10266H045DV 2**: +1.20 UEF (+48.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,233 kWh/yr for American HPS10266H045DV 2** runs ~$224/yr vs. ~$901/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPS10266H045DV 2**: 10-year operating spend spans $1,804 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,817 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: American HPS10266H045DV 2** (3.7 UEF) compares closely with A. O. Smith HPS10-66H45DV 2** (3.7 UEF, at parity) and Lochinvar HPSA065KD 2** (3.7 UEF, at parity).

## What Physical and Thermal Ratings Define American HPS10266H045DV 2**?

Positioning at #347 of 706 out of 706 Hybrid/Electric Heat Pump peers, American HPS10266H045DV 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [American](https://gcsradheat.com/brands/american/) | 79 certified listings | ENERGY STAR PD 2408850 |
| Model Number | HPS10266H045DV 2** | Draw pattern: High-Usage | HPS10266H045DV 2** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,233 kWh/yr | +161 kWh/yr vs. 1,072 kWh/yr median | Est. $224/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 425% | -4.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## Why Do State Utility Rates Shift HPS10266H045DV 2** Running Costs?

Consuming 1,233 kWh annually puts American HPS10266H045DV 2** near $224/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $224/yr | $2,239 | $6,766 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $582/yr | $5,817 | $17,579 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $367/yr | $3,668 | $11,085 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,962 | $5,928 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $180/yr | $1,804 | $5,451 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,233 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any American Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## What Are 5 Direct Alternatives to American HPS10266H045DV 2**?

Homeowners cross-shopping American HPS10266H045DV 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPS10-66H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hps10-66h45dv-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [Lochinvar HPSA065KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpsa065kd-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [RELIANCE WATER HEATERS 10-66-DHPTS 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-66-dhpts-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [State HPSX-66-DHPT 2**](https://gcsradheat.com/water-heaters/state/hpsx-66-dhpt-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |
| [A. O. Smith HPSN10-66H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpsn10-66h45dv-2/) | Hybrid/Electric Heat Pump | 67 gal | 82 gal | 3.7 (at parity) | 1,233 |

## When Should Homeowners Skip American HPS10266H045DV 2** (Hybrid/Electric Heat Pump)?

Check American HPS10266H045DV 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.

### Key Limitations & Exclusions

- American HPS10266H045DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPS10266H045DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing American HPS10266H045DV 2 Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPS10-66H45DV 2** footprint.

## Sizing, Efficiency & Recall Answers for American HPS10266H045DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will American HPS10266H045DV 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.7 UEF, American HPS10266H045DV 2** shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPS10-66H45DV 2**.

### Will American HPS10266H045DV 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, American HPS10266H045DV 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support American HPS10266H045DV 2** during replacement?

Electrical specs for American HPS10266H045DV 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for American HPS10266H045DV 2**?

At 18.16 cents/kWh national residential pricing, American HPS10266H045DV 2**'s 1,233 kWh/yr draw equals roughly $224 annually or $2,240 across a 10-year horizon (ranging from $180/yr in Washington hydro tiers up to $582/yr in Hawaii).

### When is American HPS10266H045DV 2** a poor fit for a residential replacement?

Avoid placing American HPS10266H045DV 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does American HPS10266H045DV 2** deliver?

With 82 gal FHR (+10 gal vs. 72 gal median), American HPS10266H045DV 2** fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on American HPS10266H045DV 2**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Does American HPS10266H045DV 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPS10266H045DV 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-66H45DV 2** (3.7 UEF).

## Related Rebate, Gas-Line & Serial Tools for HPS10266H045DV 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPS10-66H45DV 2** (3.7 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hps10-66h45dv-2/)
- [Compare Lochinvar HPSA065KD 2** (3.7 UEF)→](https://gcsradheat.com/water-heaters/lochinvar/hpsa065kd-2/)
- [View All American Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)