title: "American PCG82-50S65L 1** (0.9 UEF, 49 gal)"
url: https://gcsradheat.com/water-heaters/american/pcg82-50s65l-1/
description: "With PD 3798668 certification, American PCG82-50S65L 1** (Gas Storage, Natural Gas, Propane) achieves a certified 0.9 UEF rating across its 49-gallon nominal."
---

ENERGY STAR water heater model · PD 3798668

# American PCG82-50S65L 1** Water Heater Specifications (0.9 UEF)

With PD 3798668 certification, American PCG82-50S65L 1** (Gas Storage, Natural Gas, Propane) achieves a certified 0.9 UEF rating across its 49-gallon nominal tank, 118 gal First Hour Rating, standing #1 of 71 across 71 peers with Pass: +0.32 / +55.2% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GC6-PS5065*V 1** (0.9 UEF).

- **Uniform Energy Factor**: 0.9 UEF

- **Cohort UEF Rank**: #1 of 71

- **First Hour Rating**: 118 gal

- **Storage Volume**: 49 gal

- **Fuel / Type**: Natural Gas, Propane / Gas Storage

- **DOE 2029 Rule Status**: Pass: +0.32 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows American PCG82-50S65L 1** relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places American PCG82-50S65L 1** at 0.9 UEF (#1 of 71; At 0.90 UEF median) in Gas Storage.

American pcg82-50s65l 1** stores 49 gal nominal; 118 gal first hour rating (+23 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

In the Gas Storage tier, A. O. Smith GC6-PS5065*V 1** (0.9 UEF, at parity) and Envirosense Enercare ENV-50N-ENER 1** (0.9 UEF, at parity) bracket American PCG82-50S65L 1**.

## What Physical and Thermal Ratings Define American PCG82-50S65L 1**?

Positioning at #1 of 71 out of 71 Gas Storage peers, American PCG82-50S65L 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [American](https://gcsradheat.com/brands/american/) | 79 certified listings | ENERGY STAR PD 3798668 |
| Model Number | PCG82-50S65L 1** | Draw pattern: High-Usage | PCG82-50S65L 1** |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 118 gal | +23 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 92% | -2.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 54.5" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 2 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-03-03 | Certified 2025-03-03 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any American Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## What Are 5 Direct Alternatives to American PCG82-50S65L 1**?

Homeowners cross-shopping American PCG82-50S65L 1** frequently review these five Gas Storage models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith GC6-PS5065*V 1**](https://gcsradheat.com/water-heaters/a-o-smith/gc6-ps5065-v-1/) | Gas Storage | 49 gal | 118 gal | 0.9 (at parity) | — |
| [Envirosense Enercare ENV-50N-ENER 1**](https://gcsradheat.com/water-heaters/envirosense-enercare/env-50n-ener-1/) | Gas Storage | 49 gal | 118 gal | 0.9 (at parity) | — |
| [Envirosense Reliance Home Comfort ENV-50N-RHC 1**](https://gcsradheat.com/water-heaters/envirosense-reliance-home-comfort/env-50n-rhc-1/) | Gas Storage | 49 gal | 118 gal | 0.9 (at parity) | — |
| [Envirosense ENV-50N 1**](https://gcsradheat.com/water-heaters/envirosense/env-50n-1/) | Gas Storage | 49 gal | 118 gal | 0.9 (at parity) | — |
| [A. O. Smith GC9-PS5065NV 1**](https://gcsradheat.com/water-heaters/a-o-smith/gc9-ps5065nv-1/) | Gas Storage | 49 gal | 118 gal | 0.9 (at parity) | — |

## Who Is American PCG82-50S65L 1** Best For — and When Should You Pick A. O. Smith GC6-PS5065*V 1**?

Evaluate whether American PCG82-50S65L 1**'s Gas Storage architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- American PCG82-50S65L 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect American PCG82-50S65L 1**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 118 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for American PCG82-50S65L 1 Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GC6-PS5065*V 1**.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Sizing, Efficiency & Recall Answers for American PCG82-50S65L 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does American PCG82-50S65L 1** (0.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American PCG82-50S65L 1** records 0.9 UEF (Pass: +0.32 / +55.2%), placing #1 of 71 out of 71 certified Gas Storage configurations.

### Does American PCG82-50S65L 1** fit inside a tight hallway closet or low-headroom utility room?

American PCG82-50S65L 1** requires room for its 54.5 in. vertical shell and 22 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern American PCG82-50S65L 1**?

Installing American PCG82-50S65L 1** on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

### What annual utility bill should homeowners budget for American PCG82-50S65L 1**?

Rated 0.9 UEF on Natural Gas, Propane, American PCG82-50S65L 1** carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas Storage models.

### What are the main drawbacks of American PCG82-50S65L 1** (0.9 UEF)?

Buyers expecting endless simultaneous shower flow beyond 118 gal should compare condensing tankless units or larger-capacity tanks.

### What hot-water delivery rating governs American PCG82-50S65L 1**?

Rated for 118 gal FHR (+23 gal vs. 95 gal median), American PCG82-50S65L 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen American PCG82-50S65L 1** for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to American PCG82-50S65L 1** in the Gas Storage class?

Closest peer in Gas Storage is A. O. Smith GC6-PS5065*V 1** (0.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Related Rebate, Gas-Line & Serial Tools for PCG82-50S65L 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith GC6-PS5065*V 1** (0.9 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/gc6-ps5065-v-1/)
- [Compare Envirosense Enercare ENV-50N-ENER 1** (0.9 UEF)→](https://gcsradheat.com/water-heaters/envirosense-enercare/env-50n-ener-1/)
- [View All American Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)