title: "American PG10 34 100 2*V 2** (0.9 UEF, 33 gal)"
url: https://gcsradheat.com/water-heaters/american/pg10-34-100-2-v-2/
description: "With PD 2408703 certification, American PG10 34 100 2*V 2** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.9 UEF."
---

ENERGY STAR water heater model · PD 2408703

# American PG10 34 100 2*V 2** Water Heater Specifications (0.9 UEF)

With PD 2408703 certification, American PG10 34 100 2*V 2** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.9 UEF rating across its 33-gallon nominal tank, 170 gal First Hour Rating, standing #2 of 71 across 71 peers with Pass: +0.32 / +55.2% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GSP-100 2** (0.9 UEF).

- **Uniform Energy Factor**: 0.9 UEF

- **Cohort UEF Rank**: #2 of 71 (top 9.9%)

- **First Hour Rating**: 170 gal

- **Storage Volume**: 33 gal

- **Fuel / Type**: Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial

- **DOE 2029 Rule Status**: Pass: +0.32 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows American PG10 34 100 2*V 2** relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places American PG10 34 100 2*V 2** at 0.9 UEF (#2 of 71; +0.02 UEF vs. 0.88 UEF median) in Gas-fired Storage Residential-duty Commercial.

American pg10 34 100 2*v 2** stores 33 gal nominal; 170 gal first hour rating (+34 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

In the Gas-fired Storage Residential-duty Commercial tier, A. O. Smith GSP-100 2** (0.9 UEF, at parity) and State GHX-34-100 N 2** (0.9 UEF, at parity) bracket American PG10 34 100 2*V 2**.

## Which Specs Set American PG10 34 100 2*V 2** Apart From Cohort Averages?

Ranked #2 of 71 (top 9.9%) inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, American PG10 34 100 2*V 2** is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [American](https://gcsradheat.com/brands/american/) | 79 certified listings | ENERGY STAR PD 2408703 |
| Model Number | PG10 34 100 2*V 2** | Draw pattern: High-Usage | PG10 34 100 2*V 2** |
| Uniform Energy Factor (UEF) | 0.9 | +0.02 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 170 gal | +34 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 95% | At 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 49" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should American Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to American; verify whether your PG10 34 100 2*V 2** production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?

Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith GSP-100 2**](https://gcsradheat.com/water-heaters/a-o-smith/gsp-100-2/) | Gas-fired Storage Residential-duty Commercial | 33 gal | 170 gal | 0.9 (at parity) | — |
| [State GHX-34-100 N 2**](https://gcsradheat.com/water-heaters/state/ghx-34-100-n-2/) | Gas-fired Storage Residential-duty Commercial | 33 gal | 170 gal | 0.9 (at parity) | — |
| [HTP PH76-50](https://gcsradheat.com/water-heaters/htp/ph76-50/) | Gas-fired Storage Residential-duty Commercial | 48 gal | 154 gal | 0.9 (at parity) | — |
| [GSW WATER HEATERS 6G5076NVC 1**](https://gcsradheat.com/water-heaters/gsw-water-heaters/6g5076nvc-1/) | Gas-fired Storage Residential-duty Commercial | 48 gal | 119 gal | 0.88 (-0.02) | — |
| [A. O. Smith GPHE-50 1**](https://gcsradheat.com/water-heaters/a-o-smith/gphe-50-1/) | Gas-fired Storage Residential-duty Commercial | 48 gal | 119 gal | 0.88 (-0.02) | — |

## What Are the Limitations of American PG10 34 100 2*V 2** and Who Should Not Install It?

Before ordering American PG10 34 100 2*V 2** (Gas-fired Storage Residential-duty Commercial, 0.9 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- American PG10 34 100 2*V 2** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect American PG10 34 100 2*V 2**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 170 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for American PG10 34 100 2*V 2 Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GSP-100 2**.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Frequently Asked Technical Questions: American PG10 34 100 2*V 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does American PG10 34 100 2*V 2** pass the May 6, 2029 federal DOE efficiency rule?

American PG10 34 100 2*V 2** carries a verified 0.9 UEF rating (Pass: +0.32 / +55.2%), ranking #2 of 71 (top 9.9%) across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.

### What doorway width and ceiling height does American PG10 34 100 2*V 2** need?

American PG10 34 100 2*V 2** stands 49 in. high with a 22 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does American PG10 34 100 2*V 2** require?

American PG10 34 100 2*V 2** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does American PG10 34 100 2*V 2** cost per year to run?

ENERGY STAR rates American PG10 34 100 2*V 2** as a Natural Gas, Propane heater (0.9 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.

### Who should NOT install American PG10 34 100 2*V 2**, and what are its limits?

American PG10 34 100 2*V 2** (0.9 UEF) is not suited for multi-bath marathon draws exceeding its 170 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

### How many bathrooms or people can American PG10 34 100 2*V 2** serve at peak demand?

American PG10 34 100 2*V 2** achieves a 170 gal First Hour Rating (+34 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for American PG10 34 100 2*V 2**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to American PG10 34 100 2*V 2**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith GSP-100 2** (0.9 UEF).

## Essential Pre-Install Guides for American PG10 34 100 2*V 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith GSP-100 2** (0.9 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/gsp-100-2/)
- [Compare State GHX-34-100 N 2** (0.9 UEF)→](https://gcsradheat.com/water-heaters/state/ghx-34-100-n-2/)
- [View All American Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)