# American VG8275T100*V Water Heater Specifications (0.86 UEF)

The American VG8275T100*V (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.86 UEF rating across its 74-gallon nominal tank, 150 gal First Hour Rating, ranking #62 of 71 among 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models (PD 4518080). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.28 / +48.3%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Closest certified alternative is A. O. Smith HDHE-75 4** (0.86 UEF).

- **Uniform Energy Factor**: 0.86 UEF

- **Cohort UEF Rank**: #62 of 71

- **First Hour Rating**: 150 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial

- **DOE 2029 Rule Status**: Pass: +0.28 / +48.3%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows American VG8275T100*V relative to the cohort median.

Efficiency comparison & rule summary

American VG8275T100*V (0.86 UEF) ranks #62 of 71 Gas-fired Storage Residential-duty Commercial models — 10-way tie; tied at bottom of cohort, -0.02 UEF below the 0.88 UEF median.

American vg8275t100*v stores 74 gal nominal; 150 gal first hour rating (+14 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d).

Peer comparison: American VG8275T100*V (0.86 UEF) compares closely with A. O. Smith HDHE-75 4** (0.86 UEF, at parity) and GSW WATER HEATERS 8G-75100*PDV-H06* 4** (0.86 UEF, at parity).

## How Complete Are the Certified Metrics for American VG8275T100*V?

Standing at #62 of 71 among 71 certified Gas-fired Storage Residential-duty Commercial heaters, American VG8275T100*V brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [American](https://gcsradheat.com/brands/american/) | 79 certified listings | ENERGY STAR PD 4518080 |
| Model Number | VG8275T100*V | Draw pattern: High-Usage | VG8275T100*V |
| Uniform Energy Factor (UEF) | 0.86 | -0.02 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 150 gal | +14 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +2.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 51.9" H x 22.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are American Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16171 (2016-05-24):** Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Water-Heating-Technologies-Recalls-Gas-Water-Heaters))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which 5 Models Offer Similar Output to VG8275T100*V?

Ordered by minimal capacity and UEF spread relative to American VG8275T100*V, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HDHE-75 4**](https://gcsradheat.com/water-heaters/a-o-smith/hdhe-75-4/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [GSW WATER HEATERS 8G-75100*PDV-H06* 4**](https://gcsradheat.com/water-heaters/gsw-water-heaters/8g-75100-pdv-h06-4/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [RELIANCE WATER HEATERS 8-75-*TPDT 4**](https://gcsradheat.com/water-heaters/reliance-water-heaters/8-75-tpdt-4/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [State GP-8-75-*TPDT 4**](https://gcsradheat.com/water-heaters/state/gp-8-75-tpdt-4/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [A. O. Smith GDHE-75 3**](https://gcsradheat.com/water-heaters/a-o-smith/gdhe-75-3/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 130 gal | 0.86 (at parity) | — |

## Who Is American VG8275T100*V Best For — and When Should You Pick A. O. Smith HDHE-75 4**?

Evaluate whether American VG8275T100*V's Gas-fired Storage Residential-duty Commercial architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- American VG8275T100*V logs 0.86 UEF (Pass: +0.28 / +48.3%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect American VG8275T100*V's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 150 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for American VG8275T100*V** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith HDHE-75 4**.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Practical Specs & Code Questions for American VG8275T100*V

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does American VG8275T100*V (0.86 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American VG8275T100*V records 0.86 UEF (Pass: +0.28 / +48.3%), placing #62 of 71 out of 71 certified Gas-fired Storage Residential-duty Commercial configurations.

### Does American VG8275T100*V fit inside a tight hallway closet or low-headroom utility room?

American VG8275T100*V requires room for its 51.9 in. vertical shell and 22.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern American VG8275T100*V?

Installing American VG8275T100*V on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

### What annual utility bill should homeowners budget for American VG8275T100*V?

Rated 0.86 UEF on Natural Gas, Propane, American VG8275T100*V carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas-fired Storage Residential-duty Commercial models.

### What are the main drawbacks of American VG8275T100*V (0.86 UEF)?

Buyers expecting endless simultaneous shower flow beyond 150 gal should compare condensing tankless units or larger-capacity tanks.

### What hot-water delivery rating governs American VG8275T100*V?

Rated for 150 gal FHR (+14 gal vs. 136 gal median), American VG8275T100*V prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen American VG8275T100*V for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to American VG8275T100*V in the Gas-fired Storage Residential-duty Commercial class?

Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith HDHE-75 4** (0.86 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Installation, Serial & DOE 2029 Links for VG8275T100*V

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HDHE-75 4** (0.86 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hdhe-75-4/)
- [Compare GSW WATER HEATERS 8G-75100*PDV-H06* 4** (0.86 UEF)→](https://gcsradheat.com/water-heaters/gsw-water-heaters/8g-75100-pdv-h06-4/)
- [View All American Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/american/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.