title: "Ariston ARIHPWH-50-T (3.83 UEF, 45 gal)"
url: https://gcsradheat.com/water-heaters/ariston/arihpwh-50-t/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Ariston ARIHPWH-50-T (Electric) achieves a certified 3.83 UEF rating across its 45-gallon nominal tank, 69 gal."
---

ENERGY STAR water heater model · PD 4437414

# Ariston ARIHPWH-50-T Water Heater Specifications (3.83 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Ariston ARIHPWH-50-T (Electric) achieves a certified 3.83 UEF rating across its 45-gallon nominal tank, 69 gal First Hour Rating (rank #230 of 706, PD 4437414) and verifies as Pass: +1.53 / +66.5% for 2029 DOE floors. Rated annual electricity draw of 848 kWh/yr equates to roughly $154/yr ($1,540 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Lennox WHHP050T45MD240S (3.83 UEF).

- **Uniform Energy Factor**: 3.83 UEF

- **Cohort UEF Rank**: #230 of 706 (top 37.8%)

- **First Hour Rating**: 69 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.53 / +66.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ariston ARIHPWH-50-T relative to the cohort median.

Efficiency comparison & rule summary

Ariston ARIHPWH-50-T records 3.83 UEF efficiency, putting it #230 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Ariston ARIHPWH-50-T exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.53 UEF (+66.5%). At EIA August 2026 national rates (18.16 cents/kWh), 848 kWh/yr for Ariston ARIHPWH-50-T runs ~$154/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ariston ARIHPWH-50-T: 10-year operating spend spans $1,241 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,001 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Ariston ARIHPWH-50-T (3.83 UEF) are Lennox WHHP050T45MD240S (3.83 UEF, at parity) and Noritz NHP-50-240 (3.85 UEF, delta +0.02).

## How Complete Are the Certified Metrics for Ariston ARIHPWH-50-T?

Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Ariston ARIHPWH-50-T brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Ariston](https://gcsradheat.com/brands/ariston/) | 8 certified listings | ENERGY STAR PD 4437414 |
| Model Number | ARIHPWH-50-T | Draw pattern: Medium-Usage | ARIHPWH-50-T |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 69 gal | -3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 848 kWh/yr | -224 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 437% | +8.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.8" H x 18.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |

## What Is the Projected Utility Bill for ARIHPWH-50-T by State?

At 848 kWh/yr, Ariston ARIHPWH-50-T averages about $154/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,540 | $4,871 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $400/yr | $4,001 | $12,654 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,523 | $7,979 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,349 | $4,267 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,241 | $3,924 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (848 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Ariston Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Ariston in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to ARIHPWH-50-T?

Ordered by minimal capacity and UEF spread relative to Ariston ARIHPWH-50-T, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Lennox WHHP050T45MD240S](https://gcsradheat.com/water-heaters/lennox/whhp050t45md240s/) | Hybrid/Electric Heat Pump | 45 gal | 69 gal | 3.83 (at parity) | 848 |
| [Noritz NHP-50-240](https://gcsradheat.com/water-heaters/noritz/nhp-50-240/) | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.85 (+0.02) | 844 |
| [Friedrich PROH50 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.05) | 846 |
| [Rheem CPROPH50 T2 RH375-SO](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh375-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.05) | 846 |
| [Friedrich PROH50 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.05) | 846 |

## Who Is Ariston ARIHPWH-50-T Best For — and When Should You Pick Lennox WHHP050T45MD240S?

Evaluate whether Ariston ARIHPWH-50-T's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Ariston ARIHPWH-50-T needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ariston ARIHPWH-50-T directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Ariston ARIHPWH-50-T** Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Lennox WHHP050T45MD240S footprint.

## Practical Specs & Code Questions for Ariston ARIHPWH-50-T

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Ariston ARIHPWH-50-T (3.83 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Ariston ARIHPWH-50-T records 3.83 UEF (Pass: +1.53 / +66.5%), placing #230 of 706 (top 37.8%) out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Ariston ARIHPWH-50-T fit inside a tight hallway closet or low-headroom utility room?

Ariston ARIHPWH-50-T requires room for its 45.8 in. vertical shell and 18.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Ariston ARIHPWH-50-T?

For Ariston ARIHPWH-50-T, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Ariston ARIHPWH-50-T?

Using 848 kWh/yr, Ariston ARIHPWH-50-T generates an estimated $154/yr electric bill at 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $400/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Ariston ARIHPWH-50-T (3.83 UEF)?

Ariston ARIHPWH-50-T requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Lennox WHHP050T45MD240S.

### What hot-water delivery rating governs Ariston ARIHPWH-50-T?

Rated for 69 gal FHR (-3 gal vs. 72 gal median), Ariston ARIHPWH-50-T prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Ariston ARIHPWH-50-T for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Ariston; use our browser-only serial decoder to inspect Ariston ARIHPWH-50-T's age and warranty window.

### What alternative models sit closest to Ariston ARIHPWH-50-T in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Lennox WHHP050T45MD240S (3.83 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Installation, Serial & DOE 2029 Links for ARIHPWH-50-T

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Lennox WHHP050T45MD240S (3.83 UEF)→](https://gcsradheat.com/water-heaters/lennox/whhp050t45md240s/)
- [Compare Noritz NHP-50-240 (3.85 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp-50-240/)
- [View All Ariston Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ariston/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)