title: "Bradford White RE2HP65**-1NCTT (4.2 UEF, 65 gal)"
url: https://gcsradheat.com/water-heaters/bradford-white/re2hp65-1nctt/
description: "The Bradford White RE2HP65**-1NCTT (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.2 UEF rating across its 65-gallon nominal tank, 82 gal First."
---

ENERGY STAR water heater model · PD 4439730

# Bradford White RE2HP65**-1NCTT Water Heater Specifications (4.2 UEF)

The Bradford White RE2HP65**-1NCTT (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.2 UEF rating across its 65-gallon nominal tank, 82 gal First Hour Rating, ranking #10 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4439730). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.70 / +68.0%. Rated annual electricity draw of 1,181 kWh/yr equates to roughly $214/yr ($2,145 over 10 years) at 18.16 cents/kWh. Closest certified alternative is JETGLAS RE2HP65*-1NCTT (4.2 UEF).

- **Uniform Energy Factor**: 4.2 UEF

- **Cohort UEF Rank**: #10 of 706 (top 2.3%)

- **First Hour Rating**: 82 gal

- **Storage Volume**: 65 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.70 / +68.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Bradford White RE2HP65**-1NCTT relative to the cohort median.

Efficiency comparison & rule summary

Bradford White RE2HP65**-1NCTT (4.2 UEF) ranks #10 of 706 Hybrid/Electric Heat Pump models — 7-way tie; top 2.3%, more efficient than 97.7% of Hybrid/Electric Heat Pump models, +0.50 UEF above the 3.70 UEF median.

Federal 2029 margin for Bradford White RE2HP65**-1NCTT: +1.70 UEF (+68.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,181 kWh/yr for Bradford White RE2HP65**-1NCTT runs ~$214/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for Bradford White RE2HP65**-1NCTT: 10-year operating spend spans $1,728 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,572 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Bradford White RE2HP65**-1NCTT (4.2 UEF) compares closely with JETGLAS RE2HP65*-1NCTT (4.2 UEF, at parity) and GE Profile PH65S10BNY01 (4.3 UEF, delta +0.10).

## How Do Bradford White RE2HP65**-1NCTT Specs Compare to Hybrid/Electric Heat Pump Medians?

Bradford White RE2HP65**-1NCTT places #10 of 706 (top 2.3%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Bradford White](https://gcsradheat.com/brands/bradford-white/) | 19 certified listings | ENERGY STAR PD 4439730 |
| Model Number | RE2HP65**-1NCTT | Draw pattern: High-Usage | RE2HP65**-1NCTT |
| Uniform Energy Factor (UEF) | 4.2 | +0.50 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,181 kWh/yr | +109 kWh/yr vs. 1,072 kWh/yr median | Est. $214/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 462% | +33.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 44.6" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 19 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-07-02 | Certified 2025-07-02 | Markets: United States, Canada |

## What Does RE2HP65**-1NCTT Cost to Operate Across State Electricity Rates?

At 1,181 kWh/yr, Bradford White RE2HP65**-1NCTT runs roughly $214/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $214/yr | $2,145 | $7,647 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $557/yr | $5,572 | $19,867 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $351/yr | $3,513 | $12,528 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,879 | $6,700 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,728 | $6,161 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,181 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Bradford White Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with Bradford White; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #02553 (2002-08-15):** CPSC, Bradford White Corporation, Announce Recall of Gas Water Heater ([CPSC Notice](https://www.cpsc.gov/Recalls/2002/CPSC-Bradford-White-Corporation-Announce-Recall-of-Gas-Water-Heater))

## Which Certified Water Heaters Match RE2HP65**-1NCTT Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Bradford White RE2HP65**-1NCTT by storage capacity and 4.2 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [JETGLAS RE2HP65*-1NCTT](https://gcsradheat.com/water-heaters/jetglas/re2hp65-1nctt/) | Hybrid/Electric Heat Pump | 65 gal | 82 gal | 4.2 (at parity) | 1,181 |
| [GE Profile PH65S10BNY01](https://gcsradheat.com/water-heaters/ge-profile/ph65s10bny01/) | Hybrid/Electric Heat Pump | 65 gal | 86 gal | 4.3 (+0.10) | 1,154 |
| [Cala Systems, Inc RDH6524M1](https://gcsradheat.com/water-heaters/cala-systems-inc/rdh6524m1/) | Hybrid/Electric Heat Pump | 65 gal | 79 gal | 3.61 (-0.59) | — |
| [Smart Solar SSG2-ES 65](https://gcsradheat.com/water-heaters/smart-solar/ssg2-es-65/) | Hybrid/Electric Heat Pump | 65 gal | 46 gal | 2.52 (-1.68) | 893 |
| [GE Profile PH65S10BPY01](https://gcsradheat.com/water-heaters/ge-profile/ph65s10bpy01/) | Hybrid/Electric Heat Pump | 65 gal | 87 gal | 4.3 (+0.10) | 1,154 |

## Who Is Bradford White RE2HP65**-1NCTT Best For — and When Should You Pick JETGLAS RE2HP65*-1NCTT?

Evaluate whether Bradford White RE2HP65**-1NCTT's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Bradford White RE2HP65**-1NCTT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Bradford White RE2HP65**-1NCTT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Bradford White RE2HP65**-1NCTT** Strong Fit — 4.2 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare JETGLAS RE2HP65*-1NCTT footprint.

## What Are the Key Questions About Bradford White RE2HP65**-1NCTT?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Bradford White RE2HP65**-1NCTT (4.2 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Bradford White RE2HP65**-1NCTT records 4.2 UEF (Pass: +1.70 / +68.0%), placing #10 of 706 (top 2.3%) out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Bradford White RE2HP65**-1NCTT fit inside a tight hallway closet or low-headroom utility room?

Bradford White RE2HP65**-1NCTT requires room for its 44.6 in. vertical shell and 22 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Bradford White RE2HP65**-1NCTT?

For Bradford White RE2HP65**-1NCTT, plan a 240V circuit at 19A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Bradford White RE2HP65**-1NCTT?

Using 1,181 kWh/yr, Bradford White RE2HP65**-1NCTT generates an estimated $214/yr electric bill at 18.16 cents/kWh (ranging from $173/yr in Washington hydro tiers up to $557/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Bradford White RE2HP65**-1NCTT (4.2 UEF)?

Bradford White RE2HP65**-1NCTT requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or JETGLAS RE2HP65*-1NCTT.

### What hot-water delivery rating governs Bradford White RE2HP65**-1NCTT?

Rated for 82 gal FHR (+10 gal vs. 72 gal median), Bradford White RE2HP65**-1NCTT prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Bradford White RE2HP65**-1NCTT for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Bradford White as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Bradford White RE2HP65**-1NCTT in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is JETGLAS RE2HP65*-1NCTT (4.2 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Which Sizing and Compliance Guides Pair with RE2HP65**-1NCTT?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare JETGLAS RE2HP65*-1NCTT (4.2 UEF)→](https://gcsradheat.com/water-heaters/jetglas/re2hp65-1nctt/)
- [Compare GE Profile PH65S10BNY01 (4.3 UEF)→](https://gcsradheat.com/water-heaters/ge-profile/ph65s10bny01/)
- [View All Bradford White Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/bradford-white/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)