title: "Carnot Labs, Inc. N51 (3.53 UEF, 47 gal)"
url: https://gcsradheat.com/water-heaters/carnot-labs-inc/n51/
description: "With PD 4529563 certification, Carnot Labs, Inc. N51 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.53 UEF rating across its 47-gallon nominal."
---

ENERGY STAR water heater model · PD 4529563

# Carnot Labs, Inc. N51 Water Heater Specifications (3.53 UEF)

With PD 4529563 certification, Carnot Labs, Inc. N51 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.53 UEF rating across its 47-gallon nominal tank, 75 gal First Hour Rating, standing #440 of 706 across 706 peers with Pass: +1.23 / +53.5% for May 6, 2029. Rated annual electricity draw of 1,404 kWh/yr equates to roughly $255/yr ($2,550 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME50HPT (3.46 UEF).

- **Uniform Energy Factor**: 3.53 UEF

- **Cohort UEF Rank**: #440 of 706

- **First Hour Rating**: 75 gal

- **Storage Volume**: 47 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.23 / +53.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Carnot Labs, Inc. N51 relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Carnot Labs, Inc. N51 at 3.53 UEF (#440 of 706; -0.17 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Carnot Labs, Inc. N51 stands +1.23 UEF (+53.5%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,404 kWh/yr for Carnot Labs, Inc. N51 runs ~$255/yr vs. ~$978/yr for a 0.92 UEF electric tank.

State electric sensitivity for Carnot Labs, Inc. N51: 10-year operating spend spans $2,054 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,624 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Hubbell ME50HPT (3.46 UEF, delta -0.07) and Noritz NHP50 (3.46 UEF, delta -0.07) bracket Carnot Labs, Inc. N51.

## Where Does Carnot Labs, Inc. N51 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Carnot Labs, Inc. N51 holds #440 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Carnot Labs, Inc. | 1 certified listing | ENERGY STAR PD 4529563 |
| Model Number | N51 | Draw pattern: High-Usage | N51 |
| Uniform Energy Factor (UEF) | 3.53 | -0.17 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,404 kWh/yr | +332 kWh/yr vs. 1,072 kWh/yr median | Est. $255/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 396.4% | -32.6 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 44.2" H x 18.9" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.9" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21.6 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-10 | Certified 2026-02-10 | Markets: United States |

## How Much Electricity Does N51 Use in Different States?

Estimated at $255/yr nationally (1,404 kWh/yr), 10-year utility spending for Carnot Labs, Inc. N51 shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $255/yr | $2,550 | $7,233 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $662/yr | $6,624 | $18,792 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $418/yr | $4,177 | $11,849 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $223/yr | $2,234 | $6,337 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $205/yr | $2,054 | $5,827 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,404 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Carnot Labs, Inc. Units?

No open CPSC recall alerts appeared for Carnot Labs, Inc. as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to N51?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Carnot Labs, Inc. N51's gallon capacity and 3.53 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Hubbell ME50HPT](https://gcsradheat.com/water-heaters/hubbell/me50hpt/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |
| [Noritz NHP50](https://gcsradheat.com/water-heaters/noritz/nhp50/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |
| [VAUGHN THERMAL ME50HPT](https://gcsradheat.com/water-heaters/vaughn-thermal/me50hpt/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |
| [1HVAC ACIQ-50G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-50g-hp-wh/) | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.22) | 855 |
| [VAUGHN THERMAL ME50HPT-CN](https://gcsradheat.com/water-heaters/vaughn-thermal/me50hpt-cn/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (-0.07) | 938 |

## When Should Homeowners Skip Carnot Labs, Inc. N51 (Hybrid/Electric Heat Pump)?

Check Carnot Labs, Inc. N51's mechanical constraints—including utility space, Electric capacity, and Pass: +1.23 / +53.5% status—against typical residential installations.

### Key Limitations & Exclusions

- Carnot Labs, Inc. N51 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Carnot Labs, Inc. N51 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Carnot Labs, Inc. N51** Strong Fit — 3.53 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Hubbell ME50HPT footprint.

## Common Homeowner Questions for Carnot Labs, Inc. N51

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Carnot Labs, Inc. N51 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.53 UEF, Carnot Labs, Inc. N51 shows Pass: +1.23 / +53.5% relative to May 6, 2029 federal DOE limits while placing #440 of 706 among 706 Hybrid/Electric Heat Pump peers like Hubbell ME50HPT.

### Will Carnot Labs, Inc. N51 fit through a standard utility door and 72-inch basement ceiling?

Measuring 44.2 in. tall by 18.9 in. diameter, Carnot Labs, Inc. N51 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.9" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Carnot Labs, Inc. N51 during replacement?

Electrical specs for Carnot Labs, Inc. N51 call for 240V at 21.6A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Carnot Labs, Inc. N51?

At 18.16 cents/kWh national residential pricing, Carnot Labs, Inc. N51's 1,404 kWh/yr draw equals roughly $255 annually or $2,550 across a 10-year horizon (ranging from $205/yr in Washington hydro tiers up to $662/yr in Hawaii).

### When is Carnot Labs, Inc. N51 a poor fit for a residential replacement?

Avoid placing Carnot Labs, Inc. N51 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Carnot Labs, Inc. N51 deliver?

With 75 gal FHR (+3 gal vs. 72 gal median), Carnot Labs, Inc. N51 fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on Carnot Labs, Inc. N51?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Carnot Labs, Inc.; verify exact manufacturing week for Carnot Labs, Inc. N51 using the Serial Number Lookup tool.

### Does Carnot Labs, Inc. N51 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Carnot Labs, Inc. N51. Closest peer in Hybrid/Electric Heat Pump is Hubbell ME50HPT (3.46 UEF).

## Next Engineering Checks for Carnot Labs, Inc. Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Hubbell ME50HPT (3.46 UEF)→](https://gcsradheat.com/water-heaters/hubbell/me50hpt/)
- [Compare Noritz NHP50 (3.46 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp50/)
- [View All Carnot Labs, Inc. Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)