title: "Dimas 300-2 (99 SUEF, 79 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/dimas/300-2/
description: "Certified at 99.0 SUEF across its 79-gallon nominal tank, Dimas 300-2 (Solar with Electric Backup, Solar + Electric Backup) places #1 of 30 out of 30 ENERGY."
---

ENERGY STAR water heater model · PD 2408036

# Dimas 300-2 Water Heater Specifications (99 SUEF)

Certified at 99.0 SUEF across its 79-gallon nominal tank, Dimas 300-2 (Solar with Electric Backup, Solar + Electric Backup) places #1 of 30 out of 30 ENERGY STAR models (PD 2408036). Its May 6, 2029 10 CFR 430.32 status reads Exempt — Solar SUEF. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Solahart ASE 302J (9.0 SUEF).

- **Solar UEF (SUEF)**: 99.0 SUEF

- **Cohort SUEF Rank**: #1 of 30 (top 40%)

- **First Hour Rating**: On-Demand

- **Storage Volume**: 79 gal

- **Fuel / Type**: Solar + Electric Backup / Solar with Electric Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows Dimas 300-2 relative to the cohort median.

Efficiency comparison & rule summary

Tested at 99.0 SUEF, Dimas 300-2 places #1 of 30 across 30 certified Solar with Electric Backup configurations (+88.15 SUEF vs. 10.85 SUEF median).

Solar collector & storage profile, OG-300 #30004369 for Dimas 300-2: Direct Thermosyphon architecture; 21.7 sq ft Flat Plate collector; 79 gal storage tank; freeze limit 39 deg F.

Closest alternatives to Dimas 300-2 include Solahart ASE 302J (9.0 SUEF, delta -90.00) alongside Tychon FPS/HP 300 (5.4 SUEF, delta -93.60).

## How Do Dimas 300-2 Specs Compare to Solar with Electric Backup Medians?

Dimas 300-2 places #1 of 30 (top 40%) across 30 certified Solar with Electric Backup configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Dimas](https://gcsradheat.com/brands/dimas/) | 3 certified listings | ENERGY STAR PD 2408036 |
| Model Number | 300-2 | Draw pattern: Very-Small-Usage | 300-2 |
| Solar Uniform Energy Factor (SUEF) | 99.0 | +88.15 SUEF vs. 10.85 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct Thermosyphon (Flat Plate) | 21.7 sq ft aperture | OG-300 #30004369 |
| Collector Freeze Tolerance | 39 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Electrical Circuit Requirements | 240 V | Collector loop pump / controller + backup element check | NEC / Branch circuit check |
| Certification Date | 2022-03-01 | Certified 2022-03-01 | Markets: United States |

## Are There Active CPSC Safety Recalls for Dimas Water Heaters?

Zero active CPSC recalls matched Dimas in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match 300-2 Most Closely?

These 5 competing Solar with Electric Backup units sit nearest to Dimas 300-2 by storage capacity and 99.0 SUEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Solahart ASE 302J](https://gcsradheat.com/water-heaters/solahart/ase-302j/) | Solar with Electric Backup | 79 gal | — | 9.0 (-90.00) | — |
| [Tychon FPS/HP 300](https://gcsradheat.com/water-heaters/tychon/fps-hp-300/) | Solar with Electric Backup | 79 gal | — | 5.4 (-93.60) | — |
| [Acevedo Unit 2-20](https://gcsradheat.com/water-heaters/acevedo/unit-2-20/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [AET DX-80-64](https://gcsradheat.com/water-heaters/aet/dx-80-64/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [Solahart ASE 302J Free Heat](https://gcsradheat.com/water-heaters/solahart/ase-302j-free-heat/) | Solar with Electric Backup | 79 gal | — | 9.0 (-90.00) | — |

## When Should Homeowners Skip Dimas 300-2 (Solar with Electric Backup)?

Check Dimas 300-2's mechanical constraints—including utility space, Solar + Electric Backup capacity, and Exempt — Solar SUEF status—against typical residential installations.

### Key Limitations & Exclusions

- Dimas 300-2 logs 99.0 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Dimas 300-2's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 79 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Dimas 300-2** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Solahart ASE 302J.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## What Are the Key Questions About Dimas 300-2?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Dimas 300-2 stay compliant after the May 6, 2029 DOE standard takes effect?

Rated at 99.0 SUEF, Dimas 300-2 uses SRCC solar collector physics exempt from the May 6, 2029 tank UEF rules, keeping it compliant alongside Solahart ASE 302J.

### Will Dimas 300-2 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted solar with electric backup chassis, Dimas 300-2 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

### Do existing utility hookups support Dimas 300-2 during replacement?

Electrical specs for Dimas 300-2 call for 240V (Collector loop pump / controller + backup element check). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Dimas 300-2?

Because Dimas 300-2 burns Solar + Electric Backup at 99.0 SUEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 30 peers.

### When is Dimas 300-2 a poor fit for a residential replacement?

Avoid Dimas 300-2 if household peak demand surpasses 79 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

### What First Hour Rating or flow capacity does Dimas 300-2 deliver?

As an on-demand Solar with Electric Backup model, Dimas 300-2 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

### How do you verify manufacturing age and recall status on Dimas 300-2?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Dimas; verify exact manufacturing week for Dimas 300-2 using the Serial Number Lookup tool.

### Does Dimas 300-2 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Dimas 300-2. Closest peer in Solar with Electric Backup is Solahart ASE 302J (9.0 SUEF).

## Which Sizing and Compliance Guides Pair with 300-2?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Solahart ASE 302J (9.0 SUEF)→](https://gcsradheat.com/water-heaters/solahart/ase-302j/)
- [Compare Tychon FPS/HP 300 (5.4 SUEF)→](https://gcsradheat.com/water-heaters/tychon/fps-hp-300/)
- [View All Dimas Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/dimas/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Check SRCC collector freeze protection, backup tank wiring, and available post-OBBBA state DOE HEAR / utility solar incentives before replacement.
[Check 2026 State Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Model Replacement Labor](https://gcsradheat.com/costs/water-heater-replacement/)