title: "Eco-Logical OMNI-50HP1-1A (3.3 UEF, 46 gal)"
url: https://gcsradheat.com/water-heaters/eco-logical/omni-50hp1-1a/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Eco-Logical OMNI-50HP1-1A (Electric) achieves a certified 3.3 UEF rating across its 46-gallon nominal tank, 50."
---

ENERGY STAR water heater model · PD 4470524

# Eco-Logical OMNI-50HP1-1A Water Heater Specifications (3.3 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Eco-Logical OMNI-50HP1-1A (Electric) achieves a certified 3.3 UEF rating across its 46-gallon nominal tank, 50 gal First Hour Rating (rank #644 of 706, PD 4470524) and verifies as Pass: +1.00 / +43.5% for 2029 DOE floors. Rated annual electricity draw of 681 kWh/yr equates to roughly $124/yr ($1,237 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-50 1** (3.35 UEF).

- **Uniform Energy Factor**: 3.3 UEF

- **Cohort UEF Rank**: #644 of 706

- **First Hour Rating**: 50 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.00 / +43.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Eco-Logical OMNI-50HP1-1A relative to the cohort median.

Efficiency comparison & rule summary

Eco-Logical OMNI-50HP1-1A records 3.3 UEF efficiency, putting it #644 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Eco-Logical OMNI-50HP1-1A exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.00 UEF (+43.5%). At EIA August 2026 national rates (18.16 cents/kWh), 681 kWh/yr for Eco-Logical OMNI-50HP1-1A runs ~$124/yr vs. ~$444/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Eco-Logical OMNI-50HP1-1A: 10-year operating spend spans $996 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,213 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Eco-Logical OMNI-50HP1-1A (3.3 UEF) are A. O. Smith FPTU-50 1** (3.35 UEF, delta +0.05) and American HPHE6250H045DV 1** (3.35 UEF, delta +0.05).

## Which Specs Set Eco-Logical OMNI-50HP1-1A Apart From Cohort Averages?

Ranked #644 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Eco-Logical OMNI-50HP1-1A is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Eco-Logical](https://gcsradheat.com/brands/eco-logical/) | 6 certified listings | ENERGY STAR PD 4470524 |
| Model Number | OMNI-50HP1-1A | Draw pattern: Low-Usage | OMNI-50HP1-1A |
| Uniform Energy Factor (UEF) | 3.3 | -0.40 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 50 gal | -22 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 681 kWh/yr | -391 kWh/yr vs. 1,072 kWh/yr median | Est. $124/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 431% | +2.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 72.7" H x 16.1" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (16.1" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 14.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-04 | Certified 2025-07-04 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact OMNI-50HP1-1A Over 10 Years?

Using EIA Table 5.6.A benchmarks, Eco-Logical OMNI-50HP1-1A's 681 kWh/yr draw translates to roughly $124/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $124/yr | $1,237 | $3,200 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $321/yr | $3,213 | $8,313 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $203/yr | $2,026 | $5,242 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $108/yr | $1,083 | $2,803 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $100/yr | $996 | $2,578 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (681 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Eco-Logical Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Eco-Logical; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith FPTU-50 1**](https://gcsradheat.com/water-heaters/a-o-smith/fptu-50-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| [American HPHE6250H045DV 1**](https://gcsradheat.com/water-heaters/american/hphe6250h045dv-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| [RELIANCE WATER HEATERS 6-50-DHPHT 1**](https://gcsradheat.com/water-heaters/reliance-water-heaters/6-50-dhpht-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| [State HP6-50-DHPT 1**](https://gcsradheat.com/water-heaters/state/hp6-50-dhpt-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |
| [U.S. Craftmaster HPHE2F50HD045VU 1**](https://gcsradheat.com/water-heaters/u-s-craftmaster/hphe2f50hd045vu-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (+0.05) | 970 |

## When Should Homeowners Skip Eco-Logical OMNI-50HP1-1A (Hybrid/Electric Heat Pump)?

Check Eco-Logical OMNI-50HP1-1A's mechanical constraints—including utility space, Electric capacity, and Pass: +1.00 / +43.5% status—against typical residential installations.

### Key Limitations & Exclusions

- Eco-Logical OMNI-50HP1-1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Eco-Logical OMNI-50HP1-1A directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Eco-Logical OMNI-50HP1-1A** Strong Fit — 3.3 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith FPTU-50 1** footprint.

## Frequently Asked Technical Questions: Eco-Logical OMNI-50HP1-1A

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Eco-Logical OMNI-50HP1-1A stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.3 UEF, Eco-Logical OMNI-50HP1-1A shows Pass: +1.00 / +43.5% relative to May 6, 2029 federal DOE limits while placing #644 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith FPTU-50 1**.

### Will Eco-Logical OMNI-50HP1-1A fit through a standard utility door and 72-inch basement ceiling?

Measuring 72.7 in. tall by 16.1 in. diameter, Eco-Logical OMNI-50HP1-1A notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (16.1" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Eco-Logical OMNI-50HP1-1A during replacement?

Electrical specs for Eco-Logical OMNI-50HP1-1A call for 120V at 14.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Eco-Logical OMNI-50HP1-1A?

At 18.16 cents/kWh national residential pricing, Eco-Logical OMNI-50HP1-1A's 681 kWh/yr draw equals roughly $124 annually or $1,240 across a 10-year horizon (ranging from $100/yr in Washington hydro tiers up to $321/yr in Hawaii).

### When is Eco-Logical OMNI-50HP1-1A a poor fit for a residential replacement?

Avoid placing Eco-Logical OMNI-50HP1-1A directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Eco-Logical OMNI-50HP1-1A deliver?

With 50 gal FHR (-22 gal vs. 72 gal median), Eco-Logical OMNI-50HP1-1A fits 1–3 person or moderate-draw homes cleanly.

### How do you verify manufacturing age and recall status on Eco-Logical OMNI-50HP1-1A?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Eco-Logical; verify exact manufacturing week for Eco-Logical OMNI-50HP1-1A using the Serial Number Lookup tool.

### Does Eco-Logical OMNI-50HP1-1A qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Eco-Logical OMNI-50HP1-1A. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-50 1** (3.35 UEF).

## Essential Pre-Install Guides for Eco-Logical OMNI-50HP1-1A

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith FPTU-50 1** (3.35 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/fptu-50-1/)
- [Compare American HPHE6250H045DV 1** (3.35 UEF)→](https://gcsradheat.com/water-heaters/american/hphe6250h045dv-1/)
- [View All Eco-Logical Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/eco-logical/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)