title: "Eco-Logical OMNI-80HP2-1A (4.11 UEF, 74 gal)"
url: https://gcsradheat.com/water-heaters/eco-logical/omni-80hp2-1a/
description: "With PD 4470523 certification, Eco-Logical OMNI-80HP2-1A (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.11 UEF rating across its 74-gallon."
---

ENERGY STAR water heater model · PD 4470523

# Eco-Logical OMNI-80HP2-1A Water Heater Specifications (4.11 UEF)

With PD 4470523 certification, Eco-Logical OMNI-80HP2-1A (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.11 UEF rating across its 74-gallon nominal tank, 82 gal First Hour Rating, standing #19 of 706 across 706 peers with Pass: +1.61 / +64.4% for May 6, 2029. Rated annual electricity draw of 1,206 kWh/yr equates to roughly $219/yr ($2,190 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-80-T (4.1 UEF).

- **Uniform Energy Factor**: 4.11 UEF

- **Cohort UEF Rank**: #19 of 706 (top 2.7%)

- **First Hour Rating**: 82 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.61 / +64.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Eco-Logical OMNI-80HP2-1A relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Eco-Logical OMNI-80HP2-1A at 4.11 UEF (#19 of 706; +0.41 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Eco-Logical OMNI-80HP2-1A stands +1.61 UEF (+64.4%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,206 kWh/yr for Eco-Logical OMNI-80HP2-1A runs ~$219/yr vs. ~$978/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Eco-Logical OMNI-80HP2-1A: 10-year operating spend spans $1,764 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,690 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Ariston ARIHPWH-80-T (4.1 UEF, delta -0.01) and Lennox WHHP080T45MD240S (4.1 UEF, delta -0.01) bracket Eco-Logical OMNI-80HP2-1A.

## How Do Eco-Logical OMNI-80HP2-1A Specs Compare to Hybrid/Electric Heat Pump Medians?

Eco-Logical OMNI-80HP2-1A places #19 of 706 (top 2.7%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Eco-Logical](https://gcsradheat.com/brands/eco-logical/) | 6 certified listings | ENERGY STAR PD 4470523 |
| Model Number | OMNI-80HP2-1A | Draw pattern: High-Usage | OMNI-80HP2-1A |
| Uniform Energy Factor (UEF) | 4.11 | +0.41 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,206 kWh/yr | +134 kWh/yr vs. 1,072 kWh/yr median | Est. $219/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 424% | -5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 73.4" H x 18.5" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (18.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 19.8 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-04 | Certified 2025-07-04 | Markets: United States, Canada |

## What Does OMNI-80HP2-1A Cost to Operate Across State Electricity Rates?

At 1,206 kWh/yr, Eco-Logical OMNI-80HP2-1A runs roughly $219/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $219/yr | $2,190 | $7,595 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $569/yr | $5,690 | $19,731 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $359/yr | $3,588 | $12,441 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $192/yr | $1,919 | $6,654 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $176/yr | $1,764 | $6,118 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,206 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Eco-Logical Water Heaters?

Zero active CPSC recalls matched Eco-Logical in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match OMNI-80HP2-1A Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Eco-Logical OMNI-80HP2-1A by storage capacity and 4.11 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Ariston ARIHPWH-80-T](https://gcsradheat.com/water-heaters/ariston/arihpwh-80-t/) | Hybrid/Electric Heat Pump | 74 gal | 88 gal | 4.1 (-0.01) | 1,210 |
| [Lennox WHHP080T45MD240S](https://gcsradheat.com/water-heaters/lennox/whhp080t45md240s/) | Hybrid/Electric Heat Pump | 74 gal | 88 gal | 4.1 (-0.01) | 1,210 |
| [Navien NWP500S080AUMB](https://gcsradheat.com/water-heaters/navien/nwp500s080aumb/) | Hybrid/Electric Heat Pump | 74 gal | 85 gal | 4.05 (-0.06) | 1,265 |
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (-0.11) | 1,240 |
| [ACIQ ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (-0.11) | 1,240 |

## Which Home Setups Are NOT a Fit for Eco-Logical OMNI-80HP2-1A?

Comparing Eco-Logical OMNI-80HP2-1A against Ariston ARIHPWH-80-T requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Eco-Logical OMNI-80HP2-1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Eco-Logical OMNI-80HP2-1A directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Eco-Logical OMNI-80HP2-1A** Strong Fit — 4.11 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Ariston ARIHPWH-80-T footprint.

## What Are the Key Questions About Eco-Logical OMNI-80HP2-1A?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Eco-Logical OMNI-80HP2-1A score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Eco-Logical OMNI-80HP2-1A logs 4.11 UEF (Pass: +1.61 / +64.4%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Eco-Logical OMNI-80HP2-1A?

With a 73.4 in. height and 18.5 in. diameter, Eco-Logical OMNI-80HP2-1A fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (18.5" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Eco-Logical OMNI-80HP2-1A?

Powered via 240V at 19.8A max, Eco-Logical OMNI-80HP2-1A requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Eco-Logical OMNI-80HP2-1A?

Annual electric spend for Eco-Logical OMNI-80HP2-1A (1,206 kWh/yr) averages $219/yr nationwide (ranging from $176/yr in Washington hydro tiers up to $569/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Eco-Logical OMNI-80HP2-1A?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Eco-Logical OMNI-80HP2-1A.

### Is Eco-Logical OMNI-80HP2-1A sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Eco-Logical OMNI-80HP2-1A at 82 gal First Hour Rating (+10 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Eco-Logical have active CPSC SaferProducts notices affecting OMNI-80HP2-1A?

Zero CPSC recall alerts matched Eco-Logical (2026-11-23 check). Keep your Eco-Logical OMNI-80HP2-1A serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Eco-Logical OMNI-80HP2-1A (4.11 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Eco-Logical OMNI-80HP2-1A. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-80-T (4.1 UEF).

## Which Sizing and Compliance Guides Pair with OMNI-80HP2-1A?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Ariston ARIHPWH-80-T (4.1 UEF)→](https://gcsradheat.com/water-heaters/ariston/arihpwh-80-t/)
- [Compare Lennox WHHP080T45MD240S (4.1 UEF)→](https://gcsradheat.com/water-heaters/lennox/whhp080t45md240s/)
- [View All Eco-Logical Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/eco-logical/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)