# Friedrich PROH50 T0 FD120-MSO Water Heater Specifications (3 UEF)

The Friedrich PROH50 T0 FD120-MSO (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 55 gal First Hour Rating, ranking #666 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3845915). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.70 / +30.4%. Rated annual electricity draw of 1,072 kWh/yr equates to roughly $195/yr ($1,947 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem PROPH50 T0 RH120-M (3.0 UEF).

- **Uniform Energy Factor**: 3.0 UEF

- **Cohort UEF Rank**: #666 of 706

- **First Hour Rating**: 55 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.70 / +30.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH50 T0 FD120-MSO relative to the cohort median.

Efficiency comparison & rule summary

Friedrich PROH50 T0 FD120-MSO (3.0 UEF) ranks #666 of 706 Hybrid/Electric Heat Pump models — 28-way tie; more efficient than 1.8% of Hybrid/Electric Heat Pump models, -0.70 UEF below the 3.70 UEF median.

Federal 2029 margin for Friedrich PROH50 T0 FD120-MSO: +0.70 UEF (+30.4%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,072 kWh/yr for Friedrich PROH50 T0 FD120-MSO runs ~$195/yr vs. ~$635/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH50 T0 FD120-MSO: 10-year operating spend spans $1,568 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,058 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Friedrich PROH50 T0 FD120-MSO (3.0 UEF) compares closely with Rheem PROPH50 T0 RH120-M (3.0 UEF, at parity) and Richmond 10E50-HP120M (3.0 UEF, at parity).

## How Complete Are the Certified Metrics for Friedrich PROH50 T0 FD120-MSO?

Standing at #666 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Friedrich PROH50 T0 FD120-MSO brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Friedrich](https://gcsradheat.com/brands/friedrich/) | 61 certified listings | ENERGY STAR PD 3845915 |
| Model Number | PROH50 T0 FD120-MSO | Draw pattern: Medium-Usage | PROH50 T0 FD120-MSO |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 55 gal | -17 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,072 kWh/yr | At 1,072 kWh/yr median | Est. $195/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 367% | -62.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.3" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 4.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |

## What Is the Projected Utility Bill for PROH50 T0 FD120-MSO by State?

At 1,072 kWh/yr, Friedrich PROH50 T0 FD120-MSO averages about $195/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $195/yr | $1,947 | $4,402 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $506/yr | $5,058 | $11,436 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $319/yr | $3,189 | $7,211 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $171/yr | $1,706 | $3,857 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $157/yr | $1,568 | $3,546 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,072 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Friedrich Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Friedrich in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to PROH50 T0 FD120-MSO?

Ordered by minimal capacity and UEF spread relative to Friedrich PROH50 T0 FD120-MSO, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Rheem PROPH50 T0 RH120-M](https://gcsradheat.com/water-heaters/rheem/proph50-t0-rh120-m/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |
| [Richmond 10E50-HP120M](https://gcsradheat.com/water-heaters/richmond/10e50-hp120m/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |
| [Ruud PROUH50 T0 RU120-M](https://gcsradheat.com/water-heaters/ruud/prouh50-t0-ru120-m/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |
| [A. O. Smith HPTV-50 2**](https://gcsradheat.com/water-heaters/a-o-smith/hptv-50-2/) | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| [Rheem PROPH50 T0 RH120-MSO](https://gcsradheat.com/water-heaters/rheem/proph50-t0-rh120-mso/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |

## What Are the Limitations of Friedrich PROH50 T0 FD120-MSO and Who Should Not Install It?

Before ordering Friedrich PROH50 T0 FD120-MSO (Hybrid/Electric Heat Pump, 3.0 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Friedrich PROH50 T0 FD120-MSO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH50 T0 FD120-MSO directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Friedrich PROH50 T0 FD120-MSO** Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Rheem PROPH50 T0 RH120-M footprint.

## Practical Specs & Code Questions for Friedrich PROH50 T0 FD120-MSO

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Friedrich PROH50 T0 FD120-MSO pass the May 6, 2029 federal DOE efficiency rule?

Friedrich PROH50 T0 FD120-MSO carries a verified 3.0 UEF rating (Pass: +0.70 / +30.4%), ranking #666 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does Friedrich PROH50 T0 FD120-MSO need?

Friedrich PROH50 T0 FD120-MSO stands 45.3 in. high with a 18 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does Friedrich PROH50 T0 FD120-MSO require?

Friedrich PROH50 T0 FD120-MSO uses a 120V branch circuit at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does Friedrich PROH50 T0 FD120-MSO cost per year to run?

Rated at 1,072 kWh/yr, Friedrich PROH50 T0 FD120-MSO costs about $195/yr ($1,950 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $157/yr in Washington hydro tiers up to $506/yr in Hawaii).

### Who should NOT install Friedrich PROH50 T0 FD120-MSO, and what are its limits?

Friedrich PROH50 T0 FD120-MSO (3.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can Friedrich PROH50 T0 FD120-MSO serve at peak demand?

Friedrich PROH50 T0 FD120-MSO achieves a 55 gal First Hour Rating (-17 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for Friedrich PROH50 T0 FD120-MSO?

No active CPSC recalls matched Friedrich as of 2026-11-23. Always decode the serial tag on Friedrich PROH50 T0 FD120-MSO because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to Friedrich PROH50 T0 FD120-MSO, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Rheem PROPH50 T0 RH120-M (3.0 UEF).

## Installation, Serial & DOE 2029 Links for PROH50 T0 FD120-MSO

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Rheem PROPH50 T0 RH120-M (3.0 UEF)→](https://gcsradheat.com/water-heaters/rheem/proph50-t0-rh120-m/)
- [Compare Richmond 10E50-HP120M (3.0 UEF)→](https://gcsradheat.com/water-heaters/richmond/10e50-hp120m/)
- [View All Friedrich Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/friedrich/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.