title: "Friedrich PROH50 T2 FD310UM (3.5 UEF, 45 gal)"
url: https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd310um/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Friedrich PROH50 T2 FD310UM (Electric) achieves a certified 3.5 UEF rating across its 45-gallon nominal tank."
---

ENERGY STAR water heater model · PD 3845914

# Friedrich PROH50 T2 FD310UM Water Heater Specifications (3.5 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Friedrich PROH50 T2 FD310UM (Electric) achieves a certified 3.5 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating (rank #481 of 706, PD 3845914) and verifies as Pass: +1.20 / +52.2% for 2029 DOE floors. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH50 T2 RH350BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 67 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +52.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH50 T2 FD310UM relative to the cohort median.

Efficiency comparison & rule summary

Friedrich PROH50 T2 FD310UM records 3.5 UEF efficiency, putting it #481 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Friedrich PROH50 T2 FD310UM exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.20 UEF (+52.2%). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Friedrich PROH50 T2 FD310UM runs ~$166/yr vs. ~$632/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH50 T2 FD310UM: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Friedrich PROH50 T2 FD310UM (3.5 UEF) are Rheem CPROPH50 T2 RH350BM (3.5 UEF, at parity) and Ruud PRO H50 T2 RU310BM (3.5 UEF, at parity).

## Where Does Friedrich PROH50 T2 FD310UM Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Friedrich PROH50 T2 FD310UM holds #481 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Friedrich](https://gcsradheat.com/brands/friedrich/) | 61 certified listings | ENERGY STAR PD 3845914 |
| Model Number | PROH50 T2 FD310UM | Draw pattern: Medium-Usage | PROH50 T2 FD310UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 400% | -29.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Much Electricity Does PROH50 T2 FD310UM Use in Different States?

Estimated at $166/yr nationally (915 kWh/yr), 10-year utility spending for Friedrich PROH50 T2 FD310UM shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,660 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,106 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,634 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,083 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,754 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (915 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Friedrich Units?

No open CPSC recall alerts appeared for Friedrich as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PROH50 T2 FD310UM?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Friedrich PROH50 T2 FD310UM's gallon capacity and 3.5 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Rheem CPROPH50 T2 RH350BM](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh350bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| [Ruud PRO H50 T2 RU310BM](https://gcsradheat.com/water-heaters/ruud/pro-h50-t2-ru310bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| [A. O. Smith HPACO-45 1**+AXST-50T 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| [American MHPCO-45 1**+MXST-50T 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| [Rheem ECE H50 T2 RH310BM](https://gcsradheat.com/water-heaters/rheem/ece-h50-t2-rh310bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |

## Who Is Friedrich PROH50 T2 FD310UM Best For — and When Should You Pick Rheem CPROPH50 T2 RH350BM?

Evaluate whether Friedrich PROH50 T2 FD310UM's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Friedrich PROH50 T2 FD310UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH50 T2 FD310UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Friedrich PROH50 T2 FD310UM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Rheem CPROPH50 T2 RH350BM footprint.

## Common Homeowner Questions for Friedrich PROH50 T2 FD310UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Friedrich PROH50 T2 FD310UM (3.5 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Friedrich PROH50 T2 FD310UM records 3.5 UEF (Pass: +1.20 / +52.2%), placing #481 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Friedrich PROH50 T2 FD310UM fit inside a tight hallway closet or low-headroom utility room?

Friedrich PROH50 T2 FD310UM requires room for its 61.8 in. vertical shell and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Friedrich PROH50 T2 FD310UM?

For Friedrich PROH50 T2 FD310UM, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Friedrich PROH50 T2 FD310UM?

Using 915 kWh/yr, Friedrich PROH50 T2 FD310UM generates an estimated $166/yr electric bill at 18.16 cents/kWh (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Friedrich PROH50 T2 FD310UM (3.5 UEF)?

Friedrich PROH50 T2 FD310UM requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Rheem CPROPH50 T2 RH350BM.

### What hot-water delivery rating governs Friedrich PROH50 T2 FD310UM?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Friedrich PROH50 T2 FD310UM prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Friedrich PROH50 T2 FD310UM for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Friedrich; use our browser-only serial decoder to inspect Friedrich PROH50 T2 FD310UM's age and warranty window.

### What alternative models sit closest to Friedrich PROH50 T2 FD310UM in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH50 T2 RH350BM (3.5 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Next Engineering Checks for Friedrich Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Rheem CPROPH50 T2 RH350BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh350bm/)
- [Compare Ruud PRO H50 T2 RU310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/ruud/pro-h50-t2-ru310bm/)
- [View All Friedrich Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/friedrich/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)