# Friedrich PROH50 T2 FD350BM Water Heater Specifications (3.5 UEF)

With PD 3994198 certification, Friedrich PROH50 T2 FD350BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, standing #481 of 706 across 706 peers with Pass: +1.20 / +52.2% for May 6, 2029. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH50 T2 RH350BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 67 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +52.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH50 T2 FD350BM relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Friedrich PROH50 T2 FD350BM at 3.5 UEF (#481 of 706; -0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Friedrich PROH50 T2 FD350BM stands +1.20 UEF (+52.2%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Friedrich PROH50 T2 FD350BM runs ~$166/yr vs. ~$632/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH50 T2 FD350BM: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Rheem CPROPH50 T2 RH350BM (3.5 UEF, at parity) and Ruud PRO H50 T2 RU310BM (3.5 UEF, at parity) bracket Friedrich PROH50 T2 FD350BM.

## What Physical and Thermal Ratings Define Friedrich PROH50 T2 FD350BM?

Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, Friedrich PROH50 T2 FD350BM pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Friedrich](https://gcsradheat.com/brands/friedrich/) | 61 certified listings | ENERGY STAR PD 3994198 |
| Model Number | PROH50 T2 FD350BM | Draw pattern: Medium-Usage | PROH50 T2 FD350BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 400% | -29.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## Why Do State Utility Rates Shift PROH50 T2 FD350BM Running Costs?

Consuming 915 kWh annually puts Friedrich PROH50 T2 FD350BM near $166/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,660 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,106 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,634 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,083 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,754 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (915 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Friedrich Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Friedrich; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Friedrich PROH50 T2 FD350BM?

Homeowners cross-shopping Friedrich PROH50 T2 FD350BM frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Rheem CPROPH50 T2 RH350BM](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh350bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| [Ruud PRO H50 T2 RU310BM](https://gcsradheat.com/water-heaters/ruud/pro-h50-t2-ru310bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| [A. O. Smith HPACO-45 1**+AXST-50T 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| [American MHPCO-45 1**+MXST-50T 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| [Rheem ECE H50 T2 RH310BM](https://gcsradheat.com/water-heaters/rheem/ece-h50-t2-rh310bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |

## Which Home Setups Are NOT a Fit for Friedrich PROH50 T2 FD350BM?

Comparing Friedrich PROH50 T2 FD350BM against Rheem CPROPH50 T2 RH350BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Friedrich PROH50 T2 FD350BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH50 T2 FD350BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Friedrich PROH50 T2 FD350BM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Rheem CPROPH50 T2 RH350BM footprint.

## Sizing, Efficiency & Recall Answers for Friedrich PROH50 T2 FD350BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Friedrich PROH50 T2 FD350BM score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Friedrich PROH50 T2 FD350BM logs 3.5 UEF (Pass: +1.20 / +52.2%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Friedrich PROH50 T2 FD350BM?

With a 61.8 in. height and 22.3 in. diameter, Friedrich PROH50 T2 FD350BM fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Friedrich PROH50 T2 FD350BM?

Powered via 240V at 21A max, Friedrich PROH50 T2 FD350BM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Friedrich PROH50 T2 FD350BM?

Annual electric spend for Friedrich PROH50 T2 FD350BM (915 kWh/yr) averages $166/yr nationwide (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Friedrich PROH50 T2 FD350BM?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Friedrich PROH50 T2 FD350BM.

### Is Friedrich PROH50 T2 FD350BM sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Friedrich PROH50 T2 FD350BM at 67 gal First Hour Rating (-5 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Friedrich have active CPSC SaferProducts notices affecting PROH50 T2 FD350BM?

Zero CPSC recall alerts matched Friedrich (2026-11-23 check). Keep your Friedrich PROH50 T2 FD350BM serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Friedrich PROH50 T2 FD350BM (3.5 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Friedrich PROH50 T2 FD350BM. Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH50 T2 RH350BM (3.5 UEF).

## Related Rebate, Gas-Line & Serial Tools for PROH50 T2 FD350BM

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Rheem CPROPH50 T2 RH350BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh350bm/)
- [Compare Ruud PRO H50 T2 RU310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/ruud/pro-h50-t2-ru310bm/)
- [View All Friedrich Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/friedrich/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)