---
title: "Friedrich PROH80 T2 FD350UM (3.5 UEF, 72 gal)"
url: https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd350um/
description: "The Friedrich PROH80 T2 FD350UM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 72-gallon nominal tank, 87 gal First Hour."
---

ENERGY STAR water heater model · PD 3994215

# Friedrich PROH80 T2 FD350UM Water Heater Specifications (3.5 UEF)

The Friedrich PROH80 T2 FD350UM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, ranking #481 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3994215). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.00 / +40.0%. Rated annual electricity draw of 1,303 kWh/yr equates to roughly $237/yr ($2,366 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH80 T2 RH350BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 87 gal

- **Storage Volume**: 72 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.00 / +40.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH80 T2 FD350UM relative to the cohort median.

Efficiency comparison & rule summary

Friedrich PROH80 T2 FD350UM (3.5 UEF) ranks #481 of 706 Hybrid/Electric Heat Pump models — 64-way tie; more efficient than 22.9% of Hybrid/Electric Heat Pump models, -0.20 UEF below the 3.70 UEF median.

Federal 2029 margin for Friedrich PROH80 T2 FD350UM: +1.00 UEF (+40.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,303 kWh/yr for Friedrich PROH80 T2 FD350UM runs ~$237/yr vs. ~$900/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH80 T2 FD350UM: 10-year operating spend spans $1,906 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,148 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Friedrich PROH80 T2 FD350UM (3.5 UEF) compares closely with Rheem CPROPH80 T2 RH350BM (3.5 UEF, at parity) and Ruud PRO H80 T2 RU310BM (3.5 UEF, at parity).

## Which Specs Set Friedrich PROH80 T2 FD350UM Apart From Cohort Averages?

Ranked #481 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Friedrich PROH80 T2 FD350UM is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Friedrich](https://gcsradheat.com/brands/friedrich/) | 61 certified listings | ENERGY STAR PD 3994215 |
| Model Number | PROH80 T2 FD350UM | Draw pattern: High-Usage | PROH80 T2 FD350UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,303 kWh/yr | +231 kWh/yr vs. 1,072 kWh/yr median | Est. $237/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 398% | -31.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Do Regional kWh Prices Impact PROH80 T2 FD350UM Over 10 Years?

Using EIA Table 5.6.A benchmarks, Friedrich PROH80 T2 FD350UM's 1,303 kWh/yr draw translates to roughly $237/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $237/yr | $2,366 | $6,636 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $615/yr | $6,148 | $17,240 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $388/yr | $3,876 | $10,871 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $207/yr | $2,073 | $5,814 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $191/yr | $1,906 | $5,346 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,303 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Friedrich Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Friedrich; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Rheem CPROPH80 T2 RH350BM](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh350bm/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |
| [Ruud PRO H80 T2 RU310BM](https://gcsradheat.com/water-heaters/ruud/pro-h80-t2-ru310bm/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |
| [Richmond 10E80-HP120M](https://gcsradheat.com/water-heaters/richmond/10e80-hp120m/) | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (-0.04) | 1,403 |
| [LG APHWC801D](https://gcsradheat.com/water-heaters/lg/aphwc801d/) | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.40) | 1,272 |
| [Rheem ECE H80 T2 RH310BM](https://gcsradheat.com/water-heaters/rheem/ece-h80-t2-rh310bm/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |

## Which Home Setups Are NOT a Fit for Friedrich PROH80 T2 FD350UM?

Comparing Friedrich PROH80 T2 FD350UM against Rheem CPROPH80 T2 RH350BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Friedrich PROH80 T2 FD350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH80 T2 FD350UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Friedrich PROH80 T2 FD350UM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Rheem CPROPH80 T2 RH350BM footprint.

## Frequently Asked Technical Questions: Friedrich PROH80 T2 FD350UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Friedrich PROH80 T2 FD350UM score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Friedrich PROH80 T2 FD350UM logs 3.5 UEF (Pass: +1.00 / +40.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Friedrich PROH80 T2 FD350UM?

With a 74.2 in. height and 24.3 in. diameter, Friedrich PROH80 T2 FD350UM fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Friedrich PROH80 T2 FD350UM?

Powered via 240V at 21A max, Friedrich PROH80 T2 FD350UM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Friedrich PROH80 T2 FD350UM?

Annual electric spend for Friedrich PROH80 T2 FD350UM (1,303 kWh/yr) averages $237/yr nationwide (ranging from $191/yr in Washington hydro tiers up to $615/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Friedrich PROH80 T2 FD350UM?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Friedrich PROH80 T2 FD350UM.

### Is Friedrich PROH80 T2 FD350UM sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Friedrich PROH80 T2 FD350UM at 87 gal First Hour Rating (+15 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Friedrich have active CPSC SaferProducts notices affecting PROH80 T2 FD350UM?

Zero CPSC recall alerts matched Friedrich (2026-11-23 check). Keep your Friedrich PROH80 T2 FD350UM serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Friedrich PROH80 T2 FD350UM (3.5 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Friedrich PROH80 T2 FD350UM. Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH80 T2 RH350BM (3.5 UEF).

## Essential Pre-Install Guides for Friedrich PROH80 T2 FD350UM

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Rheem CPROPH80 T2 RH350BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh350bm/)
- [Compare Ruud PRO H80 T2 RU310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/ruud/pro-h80-t2-ru310bm/)
- [View All Friedrich Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/friedrich/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
