title: "GE Profile PH40S10BPY01 (4.2 UEF, 40 gal)"
url: https://gcsradheat.com/water-heaters/ge-profile/ph40s10bpy01/
description: "In the 706-unit Hybrid/Electric Heat Pump class, GE Profile PH40S10BPY01 (Electric) achieves a certified 4.2 UEF rating across its 40-gallon nominal tank, 64."
---

ENERGY STAR water heater model · PD 4016264

# GE Profile PH40S10BPY01 Water Heater Specifications (4.2 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, GE Profile PH40S10BPY01 (Electric) achieves a certified 4.2 UEF rating across its 40-gallon nominal tank, 64 gal First Hour Rating (rank #10 of 706, PD 4016264) and verifies as Pass: +1.90 / +82.6% for 2029 DOE floors. Rated annual electricity draw of 773 kWh/yr equates to roughly $140/yr ($1,404 over 10 years) at 18.16 cents/kWh. Closest certified alternative is SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF).

- **Uniform Energy Factor**: 4.2 UEF

- **Cohort UEF Rank**: #10 of 706 (top 2.3%)

- **First Hour Rating**: 64 gal

- **Storage Volume**: 40 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.90 / +82.6%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PH40S10BPY01 relative to the cohort median.

Efficiency comparison & rule summary

GE Profile PH40S10BPY01 records 4.2 UEF efficiency, putting it #10 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: GE Profile PH40S10BPY01 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.90 UEF (+82.6%). At EIA August 2026 national rates (18.16 cents/kWh), 773 kWh/yr for GE Profile PH40S10BPY01 runs ~$140/yr vs. ~$641/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PH40S10BPY01: 10-year operating spend spans $1,131 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,647 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside GE Profile PH40S10BPY01 (4.2 UEF) are SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF, delta -0.50) and AMERICAN STANDARD WATER HEATERS ASHPWH-40* (3.58 UEF, delta -0.62).

## What Physical and Thermal Ratings Define GE Profile PH40S10BPY01?

Positioning at #10 of 706 (top 2.3%) out of 706 Hybrid/Electric Heat Pump peers, GE Profile PH40S10BPY01 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [GE Profile](https://gcsradheat.com/brands/ge-profile/) | 18 certified listings | ENERGY STAR PD 4016264 |
| Model Number | PH40S10BPY01 | Draw pattern: Medium-Usage | PH40S10BPY01 |
| Uniform Energy Factor (UEF) | 4.2 | +0.50 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 64 gal | -8 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 773 kWh/yr | -299 kWh/yr vs. 1,072 kWh/yr median | Est. $140/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 499% | +70.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 39.4" H x 18.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-05-28 | Certified 2025-05-28 | Markets: United States |

## Why Do State Utility Rates Shift PH40S10BPY01 Running Costs?

Consuming 773 kWh annually puts GE Profile PH40S10BPY01 near $140/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $140/yr | $1,404 | $5,005 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $365/yr | $3,647 | $13,003 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $230/yr | $2,300 | $8,199 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $123/yr | $1,230 | $4,385 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $113/yr | $1,131 | $4,032 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (773 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any GE Profile Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for GE Profile; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to GE Profile PH40S10BPY01?

Homeowners cross-shopping GE Profile PH40S10BPY01 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [SANCO2 GS5-45HPC-D HP + ECO-43SSAQB](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-43ssaqb/) | Hybrid/Electric Heat Pump | 43 gal | 73 gal | 3.7 (-0.50) | 868 |
| [AMERICAN STANDARD WATER HEATERS ASHPWH-40*](https://gcsradheat.com/water-heaters/american-standard-water-heaters/ashpwh-40/) | Hybrid/Electric Heat Pump | 37 gal | 66 gal | 3.58 (-0.62) | 907 |
| [Ariston ARIHPWH-40](https://gcsradheat.com/water-heaters/ariston/arihpwh-40/) | Hybrid/Electric Heat Pump | 37 gal | 66 gal | 3.58 (-0.62) | 907 |
| [Lennox WHHP040T45MD240S](https://gcsradheat.com/water-heaters/lennox/whhp040t45md240s/) | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (-0.65) | 915 |
| [SANCO2 GS5-45HPC HP + ECO-43SSAQB](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-hp-eco-43ssaqb/) | Hybrid/Electric Heat Pump | 43 gal | 73 gal | 3.7 (-0.50) | 868 |

## When Should Homeowners Skip GE Profile PH40S10BPY01 (Hybrid/Electric Heat Pump)?

Check GE Profile PH40S10BPY01's mechanical constraints—including utility space, Electric capacity, and Pass: +1.90 / +82.6% status—against typical residential installations.

### Key Limitations & Exclusions

- GE Profile PH40S10BPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PH40S10BPY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing GE Profile PH40S10BPY01** Strong Fit — 4.2 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare SANCO2 GS5-45HPC-D HP + ECO-43SSAQB footprint.

## Sizing, Efficiency & Recall Answers for GE Profile PH40S10BPY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will GE Profile PH40S10BPY01 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.2 UEF, GE Profile PH40S10BPY01 shows Pass: +1.90 / +82.6% relative to May 6, 2029 federal DOE limits while placing #10 of 706 (top 2.3%) among 706 Hybrid/Electric Heat Pump peers like SANCO2 GS5-45HPC-D HP + ECO-43SSAQB.

### Will GE Profile PH40S10BPY01 fit through a standard utility door and 72-inch basement ceiling?

Measuring 39.4 in. tall by 18.5 in. diameter, GE Profile PH40S10BPY01 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support GE Profile PH40S10BPY01 during replacement?

Electrical specs for GE Profile PH40S10BPY01 call for 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for GE Profile PH40S10BPY01?

At 18.16 cents/kWh national residential pricing, GE Profile PH40S10BPY01's 773 kWh/yr draw equals roughly $140 annually or $1,400 across a 10-year horizon (ranging from $113/yr in Washington hydro tiers up to $365/yr in Hawaii).

### When is GE Profile PH40S10BPY01 a poor fit for a residential replacement?

Avoid placing GE Profile PH40S10BPY01 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 41 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does GE Profile PH40S10BPY01 deliver?

With 64 gal FHR (-8 gal vs. 72 gal median), GE Profile PH40S10BPY01 fits 1–3 person or moderate-draw homes cleanly.

### How do you verify manufacturing age and recall status on GE Profile PH40S10BPY01?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for GE Profile; verify exact manufacturing week for GE Profile PH40S10BPY01 using the Serial Number Lookup tool.

### Does GE Profile PH40S10BPY01 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for GE Profile PH40S10BPY01. Closest peer in Hybrid/Electric Heat Pump is SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF).

## Related Rebate, Gas-Line & Serial Tools for PH40S10BPY01

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF)→](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-43ssaqb/)
- [Compare AMERICAN STANDARD WATER HEATERS ASHPWH-40* (3.58 UEF)→](https://gcsradheat.com/water-heaters/american-standard-water-heaters/ashpwh-40/)
- [View All GE Profile Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ge-profile/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)