title: "GE Profile PH65S10BNY01 (4.3 UEF, 65 gal)"
url: https://gcsradheat.com/water-heaters/ge-profile/ph65s10bny01/
description: "The GE Profile PH65S10BNY01 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.3 UEF rating across its 65-gallon nominal tank, 86 gal First Hour."
---

ENERGY STAR water heater model · PD 4480875

# GE Profile PH65S10BNY01 Water Heater Specifications (4.3 UEF)

The GE Profile PH65S10BNY01 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.3 UEF rating across its 65-gallon nominal tank, 86 gal First Hour Rating, ranking #5 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4480875). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.80 / +72.0%. Rated annual electricity draw of 1,154 kWh/yr equates to roughly $210/yr ($2,096 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bradford White RE2HP65**-1NCTT (4.2 UEF).

- **Uniform Energy Factor**: 4.3 UEF

- **Cohort UEF Rank**: #5 of 706 (top 1%)

- **First Hour Rating**: 86 gal

- **Storage Volume**: 65 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.80 / +72.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PH65S10BNY01 relative to the cohort median.

Efficiency comparison & rule summary

GE Profile PH65S10BNY01 (4.3 UEF) ranks #5 of 706 Hybrid/Electric Heat Pump models — 3-way tie; top 1%, more efficient than 99% of Hybrid/Electric Heat Pump models, +0.60 UEF above the 3.70 UEF median.

Federal 2029 margin for GE Profile PH65S10BNY01: +1.80 UEF (+72.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,154 kWh/yr for GE Profile PH65S10BNY01 runs ~$210/yr vs. ~$980/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PH65S10BNY01: 10-year operating spend spans $1,688 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,445 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: GE Profile PH65S10BNY01 (4.3 UEF) compares closely with Bradford White RE2HP65**-1NCTT (4.2 UEF, delta -0.10) and JETGLAS RE2HP65*-1NCTT (4.2 UEF, delta -0.10).

## How Do GE Profile PH65S10BNY01 Specs Compare to Hybrid/Electric Heat Pump Medians?

GE Profile PH65S10BNY01 places #5 of 706 (top 1%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [GE Profile](https://gcsradheat.com/brands/ge-profile/) | 18 certified listings | ENERGY STAR PD 4480875 |
| Model Number | PH65S10BNY01 | Draw pattern: High-Usage | PH65S10BNY01 |
| Uniform Energy Factor (UEF) | 4.3 | +0.60 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,154 kWh/yr | +82 kWh/yr vs. 1,072 kWh/yr median | Est. $210/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 471% | +42.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.5" H x 21.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-30 | Certified 2025-07-30 | Markets: United States |

## What Does PH65S10BNY01 Cost to Operate Across State Electricity Rates?

At 1,154 kWh/yr, GE Profile PH65S10BNY01 runs roughly $210/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $210/yr | $2,096 | $7,700 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $544/yr | $5,445 | $20,004 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $343/yr | $3,433 | $12,614 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $184/yr | $1,836 | $6,746 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $169/yr | $1,688 | $6,203 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,154 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for GE Profile Water Heaters?

Zero active CPSC recalls matched GE Profile in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match PH65S10BNY01 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to GE Profile PH65S10BNY01 by storage capacity and 4.3 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Bradford White RE2HP65**-1NCTT](https://gcsradheat.com/water-heaters/bradford-white/re2hp65-1nctt/) | Hybrid/Electric Heat Pump | 65 gal | 82 gal | 4.2 (-0.10) | 1,181 |
| [JETGLAS RE2HP65*-1NCTT](https://gcsradheat.com/water-heaters/jetglas/re2hp65-1nctt/) | Hybrid/Electric Heat Pump | 65 gal | 82 gal | 4.2 (-0.10) | 1,181 |
| [Cala Systems, Inc RDH6524M1](https://gcsradheat.com/water-heaters/cala-systems-inc/rdh6524m1/) | Hybrid/Electric Heat Pump | 65 gal | 79 gal | 3.61 (-0.69) | — |
| [Smart Solar SSG2-ES 65](https://gcsradheat.com/water-heaters/smart-solar/ssg2-es-65/) | Hybrid/Electric Heat Pump | 65 gal | 46 gal | 2.52 (-1.78) | 893 |
| [Bradford White RE2H65T**-*](https://gcsradheat.com/water-heaters/bradford-white/re2h65t/) | Hybrid/Electric Heat Pump | 64 gal | 79 gal | 3.64 (-0.66) | 1,363 |

## Which Home Setups Are NOT a Fit for GE Profile PH65S10BNY01?

Comparing GE Profile PH65S10BNY01 against Bradford White RE2HP65**-1NCTT requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- GE Profile PH65S10BNY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PH65S10BNY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing GE Profile PH65S10BNY01** Strong Fit — 4.3 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Bradford White RE2HP65**-1NCTT footprint.

## What Are the Key Questions About GE Profile PH65S10BNY01?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does GE Profile PH65S10BNY01 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; GE Profile PH65S10BNY01 logs 4.3 UEF (Pass: +1.80 / +72.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing GE Profile PH65S10BNY01?

With a 47.5 in. height and 21.5 in. diameter, GE Profile PH65S10BNY01 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits GE Profile PH65S10BNY01?

Powered via 240V at 23A max, GE Profile PH65S10BNY01 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for GE Profile PH65S10BNY01?

Annual electric spend for GE Profile PH65S10BNY01 (1,154 kWh/yr) averages $210/yr nationwide (ranging from $169/yr in Washington hydro tiers up to $544/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing GE Profile PH65S10BNY01?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on GE Profile PH65S10BNY01.

### Is GE Profile PH65S10BNY01 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies GE Profile PH65S10BNY01 at 86 gal First Hour Rating (+14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does GE Profile have active CPSC SaferProducts notices affecting PH65S10BNY01?

Zero CPSC recall alerts matched GE Profile (2026-11-23 check). Keep your GE Profile PH65S10BNY01 serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches GE Profile PH65S10BNY01 (4.3 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for GE Profile PH65S10BNY01. Closest peer in Hybrid/Electric Heat Pump is Bradford White RE2HP65**-1NCTT (4.2 UEF).

## Which Sizing and Compliance Guides Pair with PH65S10BNY01?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Bradford White RE2HP65**-1NCTT (4.2 UEF)→](https://gcsradheat.com/water-heaters/bradford-white/re2hp65-1nctt/)
- [Compare JETGLAS RE2HP65*-1NCTT (4.2 UEF)→](https://gcsradheat.com/water-heaters/jetglas/re2hp65-1nctt/)
- [View All GE Profile Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ge-profile/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)