title: "GE Profile PH65S10BPY01 (4.3 UEF, 65 gal)"
url: https://gcsradheat.com/water-heaters/ge-profile/ph65s10bpy01/
description: "In the 706-unit Hybrid/Electric Heat Pump class, GE Profile PH65S10BPY01 (Electric) achieves a certified 4.3 UEF rating across its 65-gallon nominal tank, 87."
---

ENERGY STAR water heater model · PD 4480874

# GE Profile PH65S10BPY01 Water Heater Specifications (4.3 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, GE Profile PH65S10BPY01 (Electric) achieves a certified 4.3 UEF rating across its 65-gallon nominal tank, 87 gal First Hour Rating (rank #5 of 706, PD 4480874) and verifies as Pass: +1.80 / +72.0% for 2029 DOE floors. Rated annual electricity draw of 1,154 kWh/yr equates to roughly $210/yr ($2,096 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bradford White RE2HP65**-1NCTT (4.2 UEF).

- **Uniform Energy Factor**: 4.3 UEF

- **Cohort UEF Rank**: #5 of 706 (top 1%)

- **First Hour Rating**: 87 gal

- **Storage Volume**: 65 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.80 / +72.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PH65S10BPY01 relative to the cohort median.

Efficiency comparison & rule summary

GE Profile PH65S10BPY01 records 4.3 UEF efficiency, putting it #5 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: GE Profile PH65S10BPY01 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.80 UEF (+72.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,154 kWh/yr for GE Profile PH65S10BPY01 runs ~$210/yr vs. ~$980/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PH65S10BPY01: 10-year operating spend spans $1,688 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,445 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside GE Profile PH65S10BPY01 (4.3 UEF) are Bradford White RE2HP65**-1NCTT (4.2 UEF, delta -0.10) and JETGLAS RE2HP65*-1NCTT (4.2 UEF, delta -0.10).

## Where Does GE Profile PH65S10BPY01 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, GE Profile PH65S10BPY01 holds #5 of 706 (top 1%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [GE Profile](https://gcsradheat.com/brands/ge-profile/) | 18 certified listings | ENERGY STAR PD 4480874 |
| Model Number | PH65S10BPY01 | Draw pattern: High-Usage | PH65S10BPY01 |
| Uniform Energy Factor (UEF) | 4.3 | +0.60 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,154 kWh/yr | +82 kWh/yr vs. 1,072 kWh/yr median | Est. $210/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 464% | +35.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.5" H x 21.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-30 | Certified 2025-07-30 | Markets: United States |

## How Much Electricity Does PH65S10BPY01 Use in Different States?

Estimated at $210/yr nationally (1,154 kWh/yr), 10-year utility spending for GE Profile PH65S10BPY01 shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $210/yr | $2,096 | $7,700 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $544/yr | $5,445 | $20,004 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $343/yr | $3,433 | $12,614 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $184/yr | $1,836 | $6,746 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $169/yr | $1,688 | $6,203 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,154 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on GE Profile Units?

No open CPSC recall alerts appeared for GE Profile as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PH65S10BPY01?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to GE Profile PH65S10BPY01's gallon capacity and 4.3 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Bradford White RE2HP65**-1NCTT](https://gcsradheat.com/water-heaters/bradford-white/re2hp65-1nctt/) | Hybrid/Electric Heat Pump | 65 gal | 82 gal | 4.2 (-0.10) | 1,181 |
| [JETGLAS RE2HP65*-1NCTT](https://gcsradheat.com/water-heaters/jetglas/re2hp65-1nctt/) | Hybrid/Electric Heat Pump | 65 gal | 82 gal | 4.2 (-0.10) | 1,181 |
| [Cala Systems, Inc RDH6524M1](https://gcsradheat.com/water-heaters/cala-systems-inc/rdh6524m1/) | Hybrid/Electric Heat Pump | 65 gal | 79 gal | 3.61 (-0.69) | — |
| [Smart Solar SSG2-ES 65](https://gcsradheat.com/water-heaters/smart-solar/ssg2-es-65/) | Hybrid/Electric Heat Pump | 65 gal | 46 gal | 2.52 (-1.78) | 893 |
| [Bradford White RE2H65T**-*](https://gcsradheat.com/water-heaters/bradford-white/re2h65t/) | Hybrid/Electric Heat Pump | 64 gal | 79 gal | 3.64 (-0.66) | 1,363 |

## Who Is GE Profile PH65S10BPY01 Best For — and When Should You Pick Bradford White RE2HP65**-1NCTT?

Evaluate whether GE Profile PH65S10BPY01's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- GE Profile PH65S10BPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PH65S10BPY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing GE Profile PH65S10BPY01** Strong Fit — 4.3 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Bradford White RE2HP65**-1NCTT footprint.

## Common Homeowner Questions for GE Profile PH65S10BPY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does GE Profile PH65S10BPY01 (4.3 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, GE Profile PH65S10BPY01 records 4.3 UEF (Pass: +1.80 / +72.0%), placing #5 of 706 (top 1%) out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does GE Profile PH65S10BPY01 fit inside a tight hallway closet or low-headroom utility room?

GE Profile PH65S10BPY01 requires room for its 47.5 in. vertical shell and 21.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern GE Profile PH65S10BPY01?

For GE Profile PH65S10BPY01, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for GE Profile PH65S10BPY01?

Using 1,154 kWh/yr, GE Profile PH65S10BPY01 generates an estimated $210/yr electric bill at 18.16 cents/kWh (ranging from $169/yr in Washington hydro tiers up to $544/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of GE Profile PH65S10BPY01 (4.3 UEF)?

GE Profile PH65S10BPY01 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Bradford White RE2HP65**-1NCTT.

### What hot-water delivery rating governs GE Profile PH65S10BPY01?

Rated for 87 gal FHR (+15 gal vs. 72 gal median), GE Profile PH65S10BPY01 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen GE Profile PH65S10BPY01 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for GE Profile; use our browser-only serial decoder to inspect GE Profile PH65S10BPY01's age and warranty window.

### What alternative models sit closest to GE Profile PH65S10BPY01 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Bradford White RE2HP65**-1NCTT (4.2 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Next Engineering Checks for GE Profile Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Bradford White RE2HP65**-1NCTT (4.2 UEF)→](https://gcsradheat.com/water-heaters/bradford-white/re2hp65-1nctt/)
- [Compare JETGLAS RE2HP65*-1NCTT (4.2 UEF)→](https://gcsradheat.com/water-heaters/jetglas/re2hp65-1nctt/)
- [View All GE Profile Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ge-profile/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)