title: "GE Profile PJ50S10FPY01 (3.2 UEF, 50 gal)"
url: https://gcsradheat.com/water-heaters/ge-profile/pj50s10fpy01/
description: "The GE Profile PJ50S10FPY01 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.2 UEF rating across its 50-gallon nominal tank, 59 gal First Hour."
---

ENERGY STAR water heater model · PD 4016270

# GE Profile PJ50S10FPY01 Water Heater Specifications (3.2 UEF)

The GE Profile PJ50S10FPY01 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.2 UEF rating across its 50-gallon nominal tank, 59 gal First Hour Rating, ranking #646 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4016270). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.90 / +39.1%. Rated annual electricity draw of 1,015 kWh/yr equates to roughly $184/yr ($1,843 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

- **Uniform Energy Factor**: 3.2 UEF

- **Cohort UEF Rank**: #646 of 706

- **First Hour Rating**: 59 gal

- **Storage Volume**: 50 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.90 / +39.1%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PJ50S10FPY01 relative to the cohort median.

Efficiency comparison & rule summary

GE Profile PJ50S10FPY01 (3.2 UEF) ranks #646 of 706 Hybrid/Electric Heat Pump models — 8-way tie; more efficient than 7.5% of Hybrid/Electric Heat Pump models, -0.50 UEF below the 3.70 UEF median.

Federal 2029 margin for GE Profile PJ50S10FPY01: +0.90 UEF (+39.1%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,015 kWh/yr for GE Profile PJ50S10FPY01 runs ~$184/yr vs. ~$641/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PJ50S10FPY01: 10-year operating spend spans $1,485 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,789 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: GE Profile PJ50S10FPY01 (3.2 UEF) compares closely with A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, delta +0.35) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, delta +0.35).

## How Do GE Profile PJ50S10FPY01 Specs Compare to Hybrid/Electric Heat Pump Medians?

GE Profile PJ50S10FPY01 places #646 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [GE Profile](https://gcsradheat.com/brands/ge-profile/) | 18 certified listings | ENERGY STAR PD 4016270 |
| Model Number | PJ50S10FPY01 | Draw pattern: Medium-Usage | PJ50S10FPY01 |
| Uniform Energy Factor (UEF) | 3.2 | -0.50 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 59 gal | -13 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,015 kWh/yr | -57 kWh/yr vs. 1,072 kWh/yr median | Est. $184/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 377% | -52.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 48.1" H x 18.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 7.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-05-28 | Certified 2025-05-28 | Markets: Canada |

## What Does PJ50S10FPY01 Cost to Operate Across State Electricity Rates?

At 1,015 kWh/yr, GE Profile PJ50S10FPY01 runs roughly $184/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $184/yr | $1,843 | $4,567 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $479/yr | $4,789 | $11,866 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $302/yr | $3,020 | $7,482 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $161/yr | $1,615 | $4,001 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $148/yr | $1,485 | $3,679 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,015 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for GE Profile Water Heaters?

Zero active CPSC recalls matched GE Profile in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match PJ50S10FPY01 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to GE Profile PJ50S10FPY01 by storage capacity and 3.2 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPACO-45 1**+AXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (+0.35) | 915 |
| [American MHPCO-45 1**+MXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (+0.35) | 915 |
| [Giant GTHPCO-45 1**+GTXST-50LBTTP 1*](https://gcsradheat.com/water-heaters/giant/gthpco-45-1-gtxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (+0.35) | 915 |
| [GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/gsw-water-heaters/ghpco-45-1-gxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (+0.35) | 915 |
| [A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1*](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45c-1-axst-50lbcttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (+0.35) | 915 |

## What Are the Limitations of GE Profile PJ50S10FPY01 and Who Should Not Install It?

Before ordering GE Profile PJ50S10FPY01 (Hybrid/Electric Heat Pump, 3.2 UEF), weigh space clearances, fuel piping, noise (41 dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- GE Profile PJ50S10FPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PJ50S10FPY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing GE Profile PJ50S10FPY01** Strong Fit — 3.2 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** footprint.

## What Are the Key Questions About GE Profile PJ50S10FPY01?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does GE Profile PJ50S10FPY01 pass the May 6, 2029 federal DOE efficiency rule?

GE Profile PJ50S10FPY01 carries a verified 3.2 UEF rating (Pass: +0.90 / +39.1%), ranking #646 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does GE Profile PJ50S10FPY01 need?

GE Profile PJ50S10FPY01 stands 48.1 in. high with a 18.5 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does GE Profile PJ50S10FPY01 require?

GE Profile PJ50S10FPY01 uses a 120V branch circuit at 7.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does GE Profile PJ50S10FPY01 cost per year to run?

Rated at 1,015 kWh/yr, GE Profile PJ50S10FPY01 costs about $184/yr ($1,840 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $148/yr in Washington hydro tiers up to $479/yr in Hawaii).

### Who should NOT install GE Profile PJ50S10FPY01, and what are its limits?

GE Profile PJ50S10FPY01 (3.2 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 41 dBA.

### How many bathrooms or people can GE Profile PJ50S10FPY01 serve at peak demand?

GE Profile PJ50S10FPY01 achieves a 59 gal First Hour Rating (-13 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for GE Profile PJ50S10FPY01?

No active CPSC recalls matched GE Profile as of 2026-11-23. Always decode the serial tag on GE Profile PJ50S10FPY01 because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to GE Profile PJ50S10FPY01, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

## Which Sizing and Compliance Guides Pair with PJ50S10FPY01?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50lbttp-1/)
- [Compare American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF)→](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50lbttp-1/)
- [View All GE Profile Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ge-profile/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)