# GE Profile PK50S10FNY01 Water Heater Specifications (4.2 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, GE Profile PK50S10FNY01 (Electric) achieves a certified 4.2 UEF rating across its 50-gallon nominal tank, 60 gal First Hour Rating (rank #10 of 706, PD 4016269) and verifies as Pass: +1.90 / +82.6% for 2029 DOE floors. Rated annual electricity draw of 773 kWh/yr equates to roughly $140/yr ($1,404 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

- **Uniform Energy Factor**: 4.2 UEF

- **Cohort UEF Rank**: #10 of 706 (top 2.3%)

- **First Hour Rating**: 60 gal

- **Storage Volume**: 50 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.90 / +82.6%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GE Profile PK50S10FNY01 relative to the cohort median.

Efficiency comparison & rule summary

GE Profile PK50S10FNY01 records 4.2 UEF efficiency, putting it #10 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: GE Profile PK50S10FNY01 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.90 UEF (+82.6%). At EIA August 2026 national rates (18.16 cents/kWh), 773 kWh/yr for GE Profile PK50S10FNY01 runs ~$140/yr vs. ~$641/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).

State electric sensitivity for GE Profile PK50S10FNY01: 10-year operating spend spans $1,131 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,647 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside GE Profile PK50S10FNY01 (4.2 UEF) are A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, delta -0.65) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, delta -0.65).

## Which Specs Set GE Profile PK50S10FNY01 Apart From Cohort Averages?

Ranked #10 of 706 (top 2.3%) inside the 706-model Hybrid/Electric Heat Pump cohort, GE Profile PK50S10FNY01 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [GE Profile](https://gcsradheat.com/brands/ge-profile/) | 18 certified listings | ENERGY STAR PD 4016269 |
| Model Number | PK50S10FNY01 | Draw pattern: Medium-Usage | PK50S10FNY01 |
| Uniform Energy Factor (UEF) | 4.2 | +0.50 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 773 kWh/yr | -299 kWh/yr vs. 1,072 kWh/yr median | Est. $140/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 500% | +71.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 48.1" H x 18.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-05-28 | Certified 2025-05-28 | Markets: Canada |

## How Do Regional kWh Prices Impact PK50S10FNY01 Over 10 Years?

Using EIA Table 5.6.A benchmarks, GE Profile PK50S10FNY01's 773 kWh/yr draw translates to roughly $140/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $140/yr | $1,404 | $5,005 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $365/yr | $3,647 | $13,003 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $230/yr | $2,300 | $8,199 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $123/yr | $1,230 | $4,385 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $113/yr | $1,131 | $4,032 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (773 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should GE Profile Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for GE Profile; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPACO-45 1**+AXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (-0.65) | 915 |
| [American MHPCO-45 1**+MXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (-0.65) | 915 |
| [Giant GTHPCO-45 1**+GTXST-50LBTTP 1*](https://gcsradheat.com/water-heaters/giant/gthpco-45-1-gtxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (-0.65) | 915 |
| [GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/gsw-water-heaters/ghpco-45-1-gxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (-0.65) | 915 |
| [A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1*](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45c-1-axst-50lbcttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (-0.65) | 915 |

## What Installation Caveats Apply Before Buying GE Profile PK50S10FNY01?

Even high-UEF units like GE Profile PK50S10FNY01 (4.2 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- GE Profile PK50S10FNY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PK50S10FNY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing GE Profile PK50S10FNY01** Strong Fit — 4.2 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** footprint.

## Frequently Asked Technical Questions: GE Profile PK50S10FNY01

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is GE Profile PK50S10FNY01 eligible for continued manufacture past May 6, 2029?

At 4.2 UEF, GE Profile PK50S10FNY01 achieves Pass: +1.90 / +82.6% for the 2029 DOE standard and stands #10 of 706 (top 2.3%) against A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** and American MHPCO-45 1**+MXST-50LBTTP 1**.

### How tall and wide is GE Profile PK50S10FNY01, and what service clearance is needed?

Physical dimensions for GE Profile PK50S10FNY01 are 48.1 in. height and 18.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.5" d)); verify stair turns and drain pan width before delivery.

### Will GE Profile PK50S10FNY01 require upgrading household electrical panels or gas piping?

GE Profile PK50S10FNY01 draws 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is GE Profile PK50S10FNY01 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $140/yr ($1,400 over 10 years) to power GE Profile PK50S10FNY01 at 773 kWh/yr under the 18.16 cents/kWh US average (ranging from $113/yr in Washington hydro tiers up to $365/yr in Hawaii).

### Which installation bottlenecks limit GE Profile PK50S10FNY01?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, GE Profile PK50S10FNY01 drops into resistance mode more often.

### How does GE Profile PK50S10FNY01 handle simultaneous showers and laundry?

Delivering 60 gal in the first hour (-12 gal vs. 72 gal median), GE Profile PK50S10FNY01 combines 50 gal tank storage with rapid burner/element recovery.

### How long is the warranty on GE Profile PK50S10FNY01 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for GE Profile as of 2026-11-23. Confirm install proof and serial manufacture year on GE Profile PK50S10FNY01 before calling service.

### How do 2026 post-OBBBA rebates affect buying GE Profile PK50S10FNY01?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

## Essential Pre-Install Guides for GE Profile PK50S10FNY01

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50lbttp-1/)
- [Compare American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF)→](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50lbttp-1/)
- [View All GE Profile Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ge-profile/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)